Documentation Number 232BSS4-2916m
11
Table 2.2: Send Only and Clear Buffer Control Characters
Ports to Transmit or
Clear Receive Buffer
Binary Value
(x = Don’t Care)
Decimal
Value
ASCII
Character
None
xxxx0000
0 or 64
“@”
A Only
xxxx0001
1 or 65
“A”
B Only
xxxx0010
2 or 66
“B”
A & B
xxxx0011
3 or 67
“C”
C Only
xxxx0100
4 or 68
“D”
A & C
xxxx0101
5 or 69
“E”
B & C
xxxx0110
6 or 70
“F”
A, B, & C
xxxx0111
7 or 71
“G”
D Only
xxxx1000
8 or 72
“H”
A & D
xxxx1001
9 or 73
“I”
B & D
xxxx1010
10 or 74
“J”
A, B, & D
xxxx1011
11 or 75
“K”
C & D
xxxx1100
12 or 76
“L”
A, C, & D
xxxx1101
13 or 77
“M”
B, C, & D
xxxx1110
14 or 78
“N”
A, B, C, & D
xxxx1111
15 or 79
“O”
Note:
The 232BSS4 ignores the upper 4 bits of the control byte. If the
Master device is incapable of sending characters outside the printable
ASCII range, decimal 64 can be added to each of the control bytes and the
switch will operate properly.
Ignore Commands – “T” + one control byte specifying the length of time to
ignore commands.
The Ignore Commands command tells the 232BSS4 to ignore all
commands from the Master device for a specific amount of time. This
command is useful if the data coming from the Master device may
contain switching commands. By switching to a port, then sending the
Ignore Commands command, all data received on the Master port of the
232BSS4 will be passed directly to the selected Slave port without
checking for a command sequence until the programmed time has
elapsed. The control byte at the end of the command tells the 232BSS4
how long to ignore commands from the Master device. This byte is
ASCII “0” – “9” (48 – 57 Decimal). Timer values for each Control byte
are given in Table 2.3.
Summary of Contents for B+B SmartWorx 232BSS4
Page 4: ...ii Documentation Number 232BSS4 2916m...
Page 8: ...4 Documentation Number 232BSS4 2916m...
Page 34: ...30 Documentation Number 232BSS4 0812 Manual...
Page 36: ...A 2 Appendix A Documentation Number 232BSS4 0812Manual 5...
Page 42: ...B 6 Appendix B Cable Charts Documentation Number 232BSS4 2916 Manual...
Page 44: ...C 2 Appendix C Documentation Number 232BSS4 0812 Manual...