background image

AVAS-402

 

Medical Video recorder   
 
 

 

Summary of Contents for AVAS-402

Page 1: ...AVAS 402 Medical Video recorder...

Page 2: ...ions 1 Strictly follow these Instructions for Use please read these safety instructions carefully 2 Please keep this User Manual for later reference any use of the product requires full understanding...

Page 3: ...time disconnect it from the power source to avoid damage by transient over voltage Caution Do not leave this equipment in an uncontrolled environment where the storage temperature is below 20 C 4 F o...

Page 4: ...standards EN 60601 1 IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety EN 60601 1 1 IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Co...

Page 5: ...matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country Note Environmental protection Follow national requirements to dispose o...

Page 6: ...ISO 7010 M002 Follow instructions for us...

Page 7: ...erated in a residential environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with this user manual it may cause harmful interference...

Page 8: ...ease have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application so...

Page 9: ...DKs and APIs for system integrators to program their video applications efficiently In other chapters the SDKs and APIs provided will be described in more detail Intended use AVAS 402 is intended to s...

Page 10: ...Class B certified Environment Temperature 0 40 C Operating 10 50 C Storage Transportation Humidity 10 90 40 C non condensing Operating 5 90 non condensing Storage Transportation Pressure 700 1060 hPa...

Page 11: ...Figure 1 2 AVAS 402 Front Panel 1 Power button blue light 2 USB 3 0 Figure 1 3 AVAS 402 Rear Panel 3 RS232 4 DVI D 5 Display Port 6 HDMI 7 USB 2 0 8 USB 3 0 9 RJ 45 10 Headphone 11 MIC...

Page 12: ...Suggested cleaning detergent 1 10 Sodium HyAVAShlorite 90 water solution 2 A solution of 90 water 6 benzyl alcohol and 3 Hydrogen Peroxide 3 Glutaraldehyde 2 4 Caution Do not immerse or rinse the AVAS...

Page 13: ...data in the memory units of the storage...

Page 14: ...pany shall translate and review by the manufacturer see SOP document number SOP_Writing_Guidelines ed 3 Experience Mentally and physical competent specific medical training to understand basic knowled...

Page 15: ...ed at the rear cover including Display port COM port HDMI port DVI D port Ethernet ports USB ports and so on Apart from the I O ports shown in below fig 2 2 additional I O ports are also included not...

Page 16: ...8 USB 3 0 X 6 9 Lan Ports RJ 45 X 2 10 Audio out Headphone 11 Audio in MIC NOTE Equipotential terminal need link to hospital ground earth system before system boot to protect operator and system...

Page 17: ...female end of the power cord to the 3 pin AC male plug of AVAS 402 2 Connect the 3 pin male plug of the power cord to an electrical outlet Figure 2 7 Connecting the power cord 2 2 2 Connecting the Gr...

Page 18: ...t POST If an error occurs an error message will be displayed on screen and you will be prompted to run the setup program 2 4 Installing System Software Recent releases of operating systems from major...

Page 19: ...g system version application software etc A complete description of the problem The exact wording of any error messages Symptoms photo or video if available Guidance and Manufacturer s Declaration Ele...

Page 20: ...ters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation in the table above applicable to the frequency of the transm...

Page 21: ...in power quality should be Surge line s line s that of a typical commercial or IEC 61000 4 5 2 kV line s to 2 kV line s to hospital environment earth earth 5 UT 95 dip 5 UT 95 dip in in UT for 0 5 cyc...

Page 22: ...e d 1 2 P d 1 2 P 80 MHz to 800 MHz Conducted 3 Vrms RF d 2 3 P 800 MHz to 2 5 GHz 150 kHz to 80 IEC 61000 4 MHz Vrms 6 where P is the maximum output Radiated RF 3 V m V m power rating of the transmit...

Page 23: ...nment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which AVAS 402 is used exceeds the applicable RF compliance lev...

Page 24: ...want to remove install any parts 3 2 Thermal The vent hole on the rear cover of AVAS 402 as well as system fans CPU fan function as a cooling air flow inlet and outlet These air inlets and outlets tra...

Page 25: ...this product through the openings in the case Doing so may be dangerous and result in fire or a dangerous electric shock Never place anything on system case before turning off the computer Never turn...

Reviews: