background image

User Manual

ARK-3532

Fanless Embedded Box PC

Summary of Contents for ARK-3532

Page 1: ...User Manual ARK 3532 Fanless Embedded Box PC ...

Page 2: ...e contains a hard copy user manual in Chinese for China CCC certifica tion purposes There is an English user manual included as a PDF file on the CD Please disregard the Chinese hard copy user manual if the product is not to be sold and or installed in China ...

Page 3: ...rnational Inc VIA is a trademark of VIA Technologies Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Cor poration Intel and Pentium are trademarks of Intel Corporation Microsoft Windows is a registered trademark of Microsoft Corp RTL is a trademark of Realtek Semi Conductor Co Ltd ESS is a trademark of ESS Technology Inc UMC is a trademark of United Microelectronics Co...

Page 4: ...fective obtain an return merchandise authori zation RMA number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty serv...

Page 5: ...es Warnings Cautions and Notes Packing List Before installation please ensure the following items have been shipped 1 x ARK 3532B Unit 1 x User Manual Simplified Chinese 1 x China RoHS 1 x Desk mounting kit 1 x WISE DeviceOn 1 x McAfee Application Control Lite Acronis Backup 11 7for Windows PC Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are...

Page 6: ...P CI ARK 3532D 00A1 LGA120 0Socket Type Up to 64GB 4 1 1 1 2 4 2 8 1 1 1 9 36V DC PCI ex4 2P CI P CI ex16 Note CPU Memory Storage and operating system included by request Part Number Description 36WSWPDOBUND11 WISE DeviceOn 36WSWPDOBD0211 McAfee Application Control Lite Acronis Backup 11 7 Simplified Chinese manual China RoHS Part Number Description 96PSA A230W24P4 3 AC to DC adapter DC 24V 230W 2...

Page 7: ... has penetrated into the equipment The equipment has been exposed to moisture The equipment is malfunctioning or does not operate according to the user manual The equipment has been dropped and damaged The equipment shows obvious signs of breakage 15 Do not leave the equipment in an environment with a storage temperature of below 40 C 40 F or above 85 C 185 F as this may cause damage The equipment...

Page 8: ... LES OUVERTURES 8 La prise de courant doit avoir une connexion mise à la terre 9 Placez le cordon d alimentation de sorte que personne ne puisse marcher des sus Ne placez rien sur le cordon d alimentation 10 Tous les avertissements et mises en garde sur l équipement doivent être notés 11 Si l appareil n est pas utilisé pendant une longue période débranchez le du sec teur pour ne pas être endommagé...

Page 9: ...n la norme CEI 704 1 1982 n est pas supérieur à 70 dB A 20 L équipement ne doit être installé que dans une zone d accès restreint 21 AVERTISSEMENT Cet ensemble d instructions est donné conformément à la norme CEI 704 1 Advantech décline toute responsabilité quant à l exactitude des déclarations contenues dans ce 22 Au moyen d un cordon d alimentation connecté à une prise de courant avec mise à la ...

Page 10: ...ARK 3532 User Manual x ...

Page 11: ...ettings 12 2 3 Connectors 14 2 3 1 ARK 3532 External I O Locations 14 Figure 2 2 ARK 3532 Front and Rear I O Connector Diagram 14 Figure 2 3 COM Connector 14 Table 2 2 COM Connector Pin Assignments 14 Table 2 3 COM Connector Pin Assignments 15 Figure 2 4 Ethernet Connector 15 Table 2 4 Ethernet Connector Pin Assignments 16 Figure 2 5 HDMI Receptacle Connector 16 Table 2 5 HDMI Connector Pin Assign...

Page 12: ...he Setup 27 3 2 1 Main Setup 27 3 2 2 Advanced BIOS Features Setup 28 3 2 3 Chipset Configuration 61 3 2 4 Security 80 3 2 5 Boot 82 3 2 6 Save Exit 83 Appendix A Watchdog Timer Sample Code 85 A 1 EC Watchdog Timer Sample Code 86 Appendix B Fixing the LAN order 87 B 1 Problem Statement 88 B 2 Addressing the LAN Order 89 ...

Page 13: ...Chapter 1 1 General Introduction This chapter details background information on the ARK 3532 series ...

Page 14: ... struc tural strengthening It supports diverse I O interfaces including 4 x Intel GbE 4 x USB 3 2 4 x USB 3 0 2 x 2 5 HDD 1 x miniPCIe 1 x M 2 E key 4 x RS 232 422 485 and 2 x RS 232 COM ports Built in Intelligent Management Tools Advantech SUSI API and WISE Devi ceOn Advantech SUSI API provides a valuable suite of programmable APIs such as multi level watchdog hardware monitoring system restorati...

Page 15: ...m 0 59 in height and 1 x mSATA Up to 4 x 2 5 SATA III HDD bays by optional AMK A0035 Expansion Interface 1 x Full size MiniPCIe support mSATA and 1 with SIM 1 x M 2 E key for Wi Fi suggested installation at Advantech manufacturing Add on Card Slot 3532B for 1 Slot PCIex4 1 Slot PCIex16 3532C for 1 Slot PCIex4 2 Slot PCI 3532D for 1 Slot PCIex4 2 Slot PCI 1 Slot PCIex16 TPM TPM 2 0 Optional 1 2 2 D...

Page 16: ...edia Encode H H 265 HEVC H 264 MPEG 4 AVC MPEG 2 JPEG MJPEG and VP8 SATA Interface Intel W480E Supports several optional selections of Serial ATA III Supports SATA data transfer rates of up to 6 Gb s Integrated AHCI controller Supports mSATA socket USB Interface Intel W480E chip supports 1 x XHCI Host Controller supporting SuperSpeed USB 3 2 Gen1 Gen2 1 x EHCI Host Controllers supporting HighSpeed...

Page 17: ...8P 90D F Audio Audio Codec ALC888S VD2 GR Compliant with HD Audio specifications Supports 16 20 24 bit DAC and 16 20 24 bit ADC resolution Supports Speak out Mic in Audio Connectors 1 x Ear Phone Jack Battery Backup Battery 3V 210 mAh with WIRE x 1 TPM TPM 2 0 1 3 2 SUSI 4 0 SUSI API Sequence Control Supported DIO 16 bit programmable DIO Watchdog Timer Multi level WDT set by Advantech iManager Pro...

Page 18: ...ARK 3532 User Manual 6 1 4 Mechanical Specifications 1 4 1 Dimensions ARK 3532B ARK 3532C W x H x D 156 x 204 x 230 mm 6 14 x 8 03 x 9 05 in 204 230 156 ...

Page 19: ...x 204 x 230 mm 7 7 x 8 03 x 9 05 in 1 4 2 Weight ARK3532B ARK3532C 5 7 kg 12 5 lb ARK3532D 6 41 kg 14 1 lb 1 5 Power Requirements 1 5 1 System power Minimum Power Input 9 36VDC Optional Adapter 150W 19V 7 89A power adapter optional 230W 24V 9 58A power adapter optional 197 230 204 ...

Page 20: ...ications 1 6 1 Operating temperature With extended peripherals 20 60 C 4 140 F with 0 7m s air flow 1 6 2 Relative humidity 95 40 C 104 F non condensing 1 6 3 Storage temperature 40 85 C 40 185 F 1 6 4 Safety UL CB CCC BSMI 1 6 5 EMC CE FCC Class B CCC BSMI ...

Page 21: ...Chapter 2 2 Hardware Configuration ...

Page 22: ...pins labeled 1 2 and 3 In this case you would connect either pins 1 and 2 or 2 and 3 The jumper settings are schematically depicted in this manual as follows A pair of needle nose pliers may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your local distributor or sales representative before you make any changes General...

Page 23: ...11 ARK 3532 User Manual Chapter 2 Hardware Configuration 2 2 3 Jumper Locations Figure 2 1 Jumper Layout ...

Page 24: ...180D M DIP 2001 WS 3 Setting Function 1 2 Auto Power On 2 3 Power Button for Power On Default JCMOS1 Clear CMOS Setting Part Number 1653003101 Footprint HD_3x1P_79_D Description PIN HEADER 3x1P 2 0 mm 180D M DIP 2000 13 WS Setting Function 1 2 Normal Operation Default 2 3 Clear CMOS MPWR_SEL1 Power Setting Part Number 1653003101 Footprint HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2...

Page 25: ...e reversal Setting Part Number 1653003101 Footprint HD_3x1P_79_D Description PIN HEADER 3x1P 2 0 mm 180D M DIP 2000 13 WS Setting Function 1 2 0 Lane numbers reversed Default 2 3 1 Normal operations J_CFG5 and J_CFG6 PCIE X16 Bifurcation Setting Part Number 1653003101 Footprint HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2000 13 WS Setting Function 1 2 1 Default 2 3 0 J1 AMO I028 RI ...

Page 26: ... connectors which offers RS 232 422 485 serial communication interface ports The default setting is RS 232 the mode RS 422 485 of ARK 3532 COM3 4 5 6 can be supported via the BIOS settings COM1 2 sup ports RS 232 COM3 COM6 Figure 2 3 COM Connector Table 2 2 COM Connector Pin Assignments RS 232 RS 422 RS 485 Pin Signal Name Signal Name Signal Name 1 DCD Tx DATA 2 RxD Tx DATA 1 2 3 4 5 6 7 8 9 ...

Page 27: ...orts provides a standard RJ 45 jack connector with LED indicators on the front side to show its Active Link status Green LED and Speed sta tus Green Orange LED Figure 2 4 Ethernet Connector 3 TxD Rx NC 4 DTR Rx NC 5 GND GND GND 6 DSR NC NC 7 RTS NC NC 8 CTS NC NC 9 RI NC NC Note NC represents No Connection Table 2 3 COM Connector Pin Assignments RS 232 Pin Signal Name 1 DCD 2 RxD 3 TxD 4 DTR 5 GND...

Page 28: ...0 Hz Please refer to Table 2 6 for its pin assign ments Figure 2 6 VGA Connector Table 2 4 Ethernet Connector Pin Assignments Pin 10 100 1000BaseT Signal Name 1 TX 2 TX 3 RX 4 MDI2 5 MDI2 6 RX 7 MDI3 8 MDI3 Table 2 5 HDMI Connector Pin Assignments Pin Signal Name Pin Signal Name 1 TMDS Data 2 2 TMDS Data 2 shield 3 TMDS Data 2 4 TMDS Data 1 5 TMDS Data 1 shield 6 TMDS Data 1 7 TMDS Data 0 8 TMDS D...

Page 29: ... 7 GND 8 GND 9 NC 10 GND 11 NC 12 DDAT 13 H SYNC 14 V SYNC 15 DCLK Table 2 7 DIO Connector Pin Assignment Pin Signal Name Pin Signal Name 1 GND 14 GND 2 Port0 D0 15 Port1 D8 3 Port0 D1 16 Port1 D9 4 Port0 D2 17 Port1 D10 5 Port0 D3 18 Port1 D11 6 Port0 D4 19 Port1 D12 7 Port0 D5 20 Port1 D13 8 Port0 D6 21 Port1 D14 9 Port0 D7 22 Port1 D15 10 5V 23 5V 11 NC 24 NC 12 NC 25 NC 13 NC Note NC represent...

Page 30: ...dards 2 3 1 8 LED Indicators There are four LEDs on the front panel that indicate the system s status HDD LED is for HDD status Figure 2 9 LED Indicators 2 3 1 9 USB3 2 Gen2 and Gen1 ARK 3532 supports 4 x USB 3 2 Gen2 10G 2 x USB 3 2 Gen1 5G and 2 x Inde pendent USB 3 2 Gen1 5G interfaces The USB interfaces complies with USB UHCI Rev 3 0 standards Please refer to Table 2 5 for its pin assignments ...

Page 31: ...witch Connector ARK 3532 provides the remote switch connector for power on off with a external cable From the left to the right are Reset GND and Power Switch On 2 4 Installation 2 4 1 CPU Memory Installation 1 Unscrew the 4 screws from the top cover and remove the top cover ...

Page 32: ...ARK 3532 User Manual 20 2 Install the CPU LGA1151 and memory into the system 3 Replace the top cover ...

Page 33: ...ard drive bay 2 Install HDD SSD with 4 x screws on the HDD SSD tray 3 Push back the hard drive bay into the system and secure it using the same screws 2 4 3 Mounting Kit Installation 1 Take out mounting kit and 4 screws M3x6L from the accessory box Retirez le kit de montage et les 4 vis M3x6L de la boîte d accessoires ...

Page 34: ...f the 2 screws M3x6L on left and right side and secure the system horizontally Vissez chaque 2 vis M3x6L sur les côtés gauche et droit et fixez le système horizontalement 2 4 4 M 2 Module MiniPCIe Module Internal SIM Card Slot Installation ...

Page 35: ...pter 2 Hardware Configuration 2 4 5 Paste the Thermal pad 1 Take the thermal pad from the accessory box 2 Paste the 30 x 30 x 0 2mm Thermal Pad on the CPU as illustrated 3 Paste 46 7 x 46 7x1mm on the Copper block as illustrated ...

Page 36: ...ARK 3532 User Manual 24 ...

Page 37: ...Chapter 3 3 BIOS Settings ...

Page 38: ...an modify BIOS settings and control various sys tem features This chapter describes the basic navigation of the ARK 3532 BIOS setup screens AMI s BIOS ROM has a built in setup program that allows users to modify the basic system configuration This information is stored in flash ROM so it retains the Setup information when the power is turned off ...

Page 39: ...he Main setup screen by selecting the Main tab There are two Main Setup options They are described in this section The Main BIOS Setup screen is shown below The Main BIOS setup screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured options in blue can The right frame displays the key legend Above the key legend is an area r...

Page 40: ...m in the left frame of the screen such as CPU Configuration to go to the sub menu for that item Users can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanced BIOS Setup options are described in this section The Advanced BIOS Setup screens are shown below The sub menus are described on the following pages 3 2 2 1 Connectivity Configuration ...

Page 41: ...Vi Mode This option configures Connectivity Discrete Bluetooth Module SerialIo UART0 needs to be enabled to select BT Module Advanced settings Configure ACPI objects for wireless devices WWAN Configuration WWAN Device Enable or Disable M 2 WWAN Device ...

Page 42: ... 3532 User Manual 30 3 2 2 2 CPU Configuration C6DRAM Enable Disable moving of DRAM contents to PRM memory when CPU is in C6 state Software Guard Extensions SGX Enable Disable Software Guard Extensions SGX ...

Page 43: ...h processor package Hyper Threading Enable or Disable Hyper Threading Technology BIST Enable Disable BIST Built In Self Test on reset AP threads Idle Manner AP threads Idle Manner for waiting signal to run MachineCheck Enable Disable Machine Check Intel Trusted Execution Technology Enables utilization of additional hardware capabilities provided by Intel Trusted Execution Technology Alias Check Re...

Page 44: ...Delay Indication Enable Disable usage of SMM_DELAYED MSR for MP sync in SMI SMM Use Block Indication Enable Disable usage of SMM_BLOCKED MSR for MP sync in SMI DGR NR11 NR10 Support Select DGR with Nifty Rock11 or Nifty Rock10 Feature ...

Page 45: ...33 ARK 3532 User Manual Chapter 3 BIOS Settings 3 2 2 3 Power and Performance CPU Power Management Control ...

Page 46: ...ation Turbo Mode Enable Disable processor Turbo Mode requires Intel Speed Step or Intel Speed Shift to be available and enabled Platform PL1 Enable Enable Disable Platform Power Limit 1 programming Platform PL1 Power Platform Power Limit 1 Power in Milli Watts Platform PL1 Time Window Platform Power Limit 1 Time Window value in seconds Platform PL2 Enable Enable Disable Platform Power Limit 2 prog...

Page 47: ...er Manual Chapter 3 BIOS Settings ower Limit 4 MSR 601h Lock When enabled PL4 configurations are locked during OS When disabled PL4 configuration can be changed during OS C states Enable Disable CPU Power Management ...

Page 48: ...indow Power Limit 1 Time Window value in seconds Power Limit 2 Override Enable Disable Power Limit 2 override Power Limit 2 Power Limit 2 value in Milli Watts Turbo Ratio Limit Ratio 0 5 TRLR Turbo Ratio Limit Ratio 0 5 TRLR with range of Max Non Turbo Ratio 255 Min Max Non Turbo Ratio Max fused turbo ratio or 255 if CPU is unlocked for overclocking Energy Efficient Turbo Enable Disable Energy Eff...

Page 49: ...37 ARK 3532 User Manual Chapter 3 BIOS Settings Number of P states Sets the number of custom P states At least 2 states must be present ...

Page 50: ...ARK 3532 User Manual 38 Power Limit 3 Override Enable Disable Power Limit 3 override Power Limit 3 Power Limit 3 in Milli Watts Power Limit 3 Time Window Power Limit 3 Time Window value in Milli seconds ...

Page 51: ...pecify the duty cycle in percentage that the CPU is required to maintain over the configured time window Range is 0 100 Power Limit 3 Lock Power Limit 3 MSR 615h Lock When enabled PL3 configurations are locked during OS When disabled PL3 configuration can be changed during OS ...

Page 52: ...K 3532 User Manual 40 CFG Lock Configure MSR 0xE2 15 CFG Lock bit Overclocking Lock Enable Disable Overclocking Lock BIT 20 in FLEX_RATIO 194 MSR RC6 Render Standby Check to enable render standby support ...

Page 53: ...nual Chapter 3 BIOS Settings Maximum GT frequency Maximum GT frequency limited by the user Disable Turbo GT frequency Enabled Disables Turbo GT frequency Disabled GT frequency is not lim ited 3 2 2 4 PCH FW Configuration ...

Page 54: ...abled Mode Manageability Features State Enable Disable Intel Manageability features AMT BIOS Features When disabled AMT BIOS Features are no longer supported and user is no lon ger able to access MEBx Setup ME Unconfig on RTC Clear When Disabled ME will not be unconfigured on RTC Clear ...

Page 55: ...43 ARK 3532 User Manual Chapter 3 BIOS Settings Me FW Image Re Flash Enable Disable Me FW Image Re Flash function FW Update Enable Disable ME FW Update function 3 2 2 5 Trusted Computing ...

Page 56: ...able or Disable Storage Hierarchy Endorsement Hierarchy Enable or Disable Endorsement Hierarchy TPM 2 0 InterfaceType Select the TCG2 Spec Version Support Physical Presence Spec Version Select to Tell O S to support PPI Spec Version 1 2 or 1 3 TPM 2 0 InterfaceType Select the Communication Interface to TPM 20 Device Device Select TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restri...

Page 57: ...apter 3 BIOS Settings 3 2 2 6 ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Enable Hibernation Enables or Disables System s ability to Hibernate OS S4 Sleep State ACPI Sleep State ...

Page 58: ...elect the highest ACPI sleep state the system will enter when the SUSPEND button is pressed S3 Video Repost Enable or Disable S3 Video Repost 3 2 2 7 Embedded Controller Configuration Power Saving Mode Select Power Saving Mode ...

Page 59: ... Chapter 3 BIOS Settings Deep Sleep delay time Set delay time for Deep Sleep mode Watchdog Timer Enabled or Disabled Watchdog Timer Start before boot to OS and must stop by self Digital I O Pin 1 16 Configure Digital I O Pin ...

Page 60: ...ARK 3532 User Manual 48 3 2 2 8 NCT61260 Super I O Configuration ...

Page 61: ...49 ARK 3532 User Manual Chapter 3 BIOS Settings Serial Port Enable or Disable Serial Port Change Settings Select an optimal settings for super IO Device COM3 6 Mode COM Mode Select ...

Page 62: ...ARK 3532 User Manual 50 3 2 2 9 NCT7802Y HW Monitor ...

Page 63: ...51 ARK 3532 User Manual Chapter 3 BIOS Settings Smart Fan Function Enable or Disable Smart Fan Fan Mode Fan Mode Select FAN Temperature 1 Input the System Smart Fan IV Temperature 1 ...

Page 64: ...em Smart Fan IV DC PWM 2 Value FAN Temperature 3 Input the System Smart Fan IV Temperature 3 FAN DC PWM 3 Input the System Smart Fan IV DC PWM 3 Value FAN Temperature 4 Input the System Smart Fan IV Temperature 4 FAN DC PWM 4 Input the System Smart Fan IV DC PWM 4 Value FAN Critical Temperature Input the System Smart IV Critical Temperature 3 2 2 10 S5 RTC Wake Settings ...

Page 65: ...53 ARK 3532 User Manual Chapter 3 BIOS Settings Wake system from S Enable or disable System wake on alarm event 3 2 2 11 AmiSetupNvlock ...

Page 66: ...ARK 3532 User Manual 54 RunTimeVariable Protection Support Enable Disable the RunTimeVariable Protection Support 3 2 2 12 Serial Port Console Redirection ...

Page 67: ...55 ARK 3532 User Manual Chapter 3 BIOS Settings Console Redirection Console Redirection Enable or Disable 3 2 2 13 Intel TXT Information ...

Page 68: ...ARK 3532 User Manual 56 3 2 2 14 USB Configuration ...

Page 69: ...off support USB Mass Storage Device Configuration Configure the USB Mass Storage Devices USB transfer time out The time out value for Control Bulk and Interrupt transfers Device reset time out USB mass storage device Start Unit command time out Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller ...

Page 70: ...ARK 3532 User Manual 58 3 2 2 15 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack IPv4 PXE Support Enable Disable IPv4 PXE boot support IPv4 HTTP Support ...

Page 71: ...IPv6 PXE Support Enable Disable IPv6 PXE boot support IPv6 HTTP Support Enable Disable IPv6 HTTP boot support PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Media detect count Number of times the presence of media will be checked 3 2 2 16 CSM Configuration ...

Page 72: ...ARK 3532 User Manual 60 CSM Support Enable Disable CSM Support 3 2 2 17 NVMe Configuration ...

Page 73: ...m the ARK 3532 setup screen to enter the Chipset BIOS Setup screen You can display a Chipset BIOS Setup option by highlighting it using the Arrow keys All Plug and Play BIOS Setup options are described in this sec tion The Plug and Play BIOS Setup screen is shown below 3 2 3 1 System Agent Configuration ...

Page 74: ...Manual 62 Memory Configuration Options VT d VT d capability Above 4GB MMIO BIOS assignment Enable Disable above 4GB Memory Mapped I O BIOS assignment This is enabled automatically when Aperture Size is set to 2048MB ...

Page 75: ...e Memory Test Run on Warm Boot Maximum Memory Frequency Maximum Memory Frequency Selections in Mhz Max TOLUD Maximum Value of TOLUD Dynamic assignment would adjust TOLUD auto matically based on largest MMIO length of installed graphic controller Fast Boot Enable Disable fast path through the MRC ...

Page 76: ...nual 64 Graphics Configuration Graphics Turbo IMON Current Graphics turbo IMON current values supported 14 31 Skip Scaning of External Gfx Card If Enable it will not scan for External Gfx Card on PEG and PCH PCIE Ports ...

Page 77: ...nal Graphics Keep IGFX enabled based on the setup options GTT Size Select the GTT Size Aperture Size Select the Aperture Size DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem Select DVMT5 0 Total Graphic Memory size used by the Internal Graphics Device PM Support Enable Disable PM Support PAVP Enable Enable Disable ...

Page 78: ...ARK 3532 User Manual 66 Enable Root Port Enable or Disable the Root Port Max Link Speed Configure PEG Max Speed PEG Slot Power Limit Value Sets the upper limit on power supplied by slot ...

Page 79: ...PEG Physical Slot Number Set the physical slot number attached to this Port Program PCIe ASPM after OpROM Enabled PCIe ASPM will be programmed after OpROM PCIe Spread Spectrum Clocking Allows disabling of Spread Spectrum Clocking for compliance testing Detect Non Compliance Device Detect Non Compliance PCI Express Device in PEG ...

Page 80: ...ARK 3532 User Manual 68 3 2 3 2 PCH IO Configuration LAN1 Controller Enable Disable onboard NIC Wake on LAN Enable Enable Disable integrated LAN to wake the system LAN1 PXE OpROM ...

Page 81: ...ler Enable Disable LAN4 controller LAN4 PXE OpROM Enable or disable boot option for LAN4 Controller PCIE Wake Enable or disable PCIE to wake the system from S5 Restore AC Power Loss Specify what state to go to when power is re applied after a power failure G3 state Flash Protection Range Registers FPRR Enable Flash Protection Range Registers PCI Express Configuration PCI Express Clock Gating PCI E...

Page 82: ...ch W A for bad USB device s connected behind PCIE PEG Port PCIe function swap When Disabled it prevents PCIE root port function swap If any function other than 0th is enabled 0th will become visible PCH PCI Express Root Port Control the PCI Express Root Port ...

Page 83: ...evel L1 Substates PCI Express L1 Substates settings PCIe Speed Configure PCIe Speed Detect Timeout The number of milliseconds reference code will wait for link to exit Detect state for enabled ports before assuming there is no device and potentially disabling the port ...

Page 84: ...ARK 3532 User Manual 72 Detect Non Compliance Device Detect Non Compliance PCI Express Device If enabled it will take more time at POST time SATA and RST Configuration ...

Page 85: ...User Manual Chapter 3 BIOS Settings SATA Controller s Enable Disable SATA Device SATA Mode Selection Determines how SATA controller s operate Aggressive LPM Support Enable PCH to aggressively enter link power state ...

Page 86: ... mSATA Port Spin Up Device If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive DITO Configuration Enable Disable DITO Configuration ...

Page 87: ...Chapter 3 BIOS Settings HDD Unlock If enabled indicates that the HDD password unlock in the OS is enabled LED Locate If enabled indicates that the LED SGPIO hardware is attached and ping to locate feature is enabled on the OS ...

Page 88: ...ARK 3532 User Manual 76 USB Configuration XHCI Compliance Mode Option to enable Compliance Mode Default is to disable Compliance Mode xDCI Support Enable Disable xDCI USB OTG Device ...

Page 89: ...bug is enabled but USB overcurrent is not disabled USB DbC will not work USB Overcurrent Lock Select Enabled if Overcurrent functionality is used Enabling this will make xHCI controller consume the Overcurrent mapping data USB Port Disable Override Selectively Enable Disable the corresponding USB port from reporting a Device Connection to the controller USB Port Power Enable Disable USB ports powe...

Page 90: ...s 38h 3Fh in the lower upper 128 byte bank of RTC RAM BIOS Lock Enable Disable the PCH BIOS Lock Enable feature Required to be enabled to ensure SMM protection of flash Force unlock on all GPIO pads If Enabled BIOS will force all GPIO pads to be in unlocked state ...

Page 91: ...79 ARK 3532 User Manual Chapter 3 BIOS Settings HD Audio Configuration HD Audio Control Detection of the HD Audio device ...

Page 92: ...ARK 3532 User Manual 80 3 2 4 Security Administrator Password Set Administrator Password User Password Set User Password ...

Page 93: ...S Settings Secure Boot Secure Boot feature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode The mode change requires plat form reset Secure Boot Mode Secure Boot mode options Standard or Custom ...

Page 94: ...n key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Fast Boot Enables or disables boot with initialization of a minimal set of devices required to launch active boot option Has no effect for BBS boot options ...

Page 95: ...er saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore...

Page 96: ...ARK 3532 User Manual 84 ...

Page 97: ...Appendix A A Watchdog Timer Sample Code ...

Page 98: ...d_Port mov al 89h Write EC HW ram out dx al mov dx EC_Data_Port mov al 5Fh Watchdog reset delay time low byte 5Eh is high byte index Timebase 100ms out dx al mov dx EC_Data_Port mov al 64h Set 10 seconds delay time out dx al mov dx EC_Command_Port mov al 89h Write EC HW ram out dx al mov dx EC_Data_Port mov al 57h Watch dog event flag out dx al mov dx EC_Data_Port mov al 04h Reset event out dx al ...

Page 99: ...Appendix B B Fixing the LAN order ...

Page 100: ... LAN chip and arrange it to the first order After installing the LAN driver the first second third LAN order will be I210 The fourth is I219 This doesn t match the LAN sign on the device cabinet Before users install the LAN driver After installing the LAN driver you will see I219 is set to Ethernet 4 I219 I210 ...

Page 101: ...e first BIOS screen Then install the Win 10 OS After installing the LAN driver the order will match the sign on the cabinet Disable the LAN 2 3 4 controller in BIOS BIOS Chipset PCH IO configuration 2 3 4 controller Disabled Before installing the LAN driver you won t see any LAN adapter After installing the LAN driver I219 will be recognized ...

Page 102: ...ARK 3532 User Manual 90 Enable LAN2 3 4 controller in BIOS Finally enter the OS to make sure the LAN order matches the sign on the cabinet I219 will become the first LAN order ...

Page 103: ...91 ARK 3532 User Manual Appendix B Fixing the LAN order ...

Page 104: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2021 ...