User’s Manual
AIMB-250 User’s Manual
41
2.4.10
Serial Port 1 Connector in RS-485 Mode (CN1)
Signal
PIN PIN
Signal
DATA-
1
2
NC
DATA+ 3 4 NC
GND
5
6
NC
NC 7
8 NC
NC
9
10
NC
2.4.10.1 Signal Description – Serial Port 1 Connector in RS-485 Mode (CN1)
Signal
Signal Description
DATA+/-
This differential signal pair sends and receives serial data to the communication
link. The mode of this differential signal pair is controlled through the RTS
register of Serial Port 2. Set the RTS register of the Serial Port 2 to LOW for
transmitting, HIGH for receiving.
Do not select a mode different from the one used by the connected peripheral,
as this may damage CPU board and/or peripheral.
The transmitter drivers in the port are short circuit protected by a thermal
protection circuit. The circuit disables the drivers when the die temperature
reaches 150
°
C.
RS-422 mode is typically used in point to point communication. Data and
control signal pairs should be terminated in the receiver end with a resistor
matching the cable impedance (typical 100-120
Ω
). The resistors could be
placed in the connector housing.
RS-485 mode is typically used in multi drop applications, where more than 2
units are communicating. The data and control signal pairs should be
terminated in each end of the communication line with a resistor matching the
cable impedance (typical 100-120
Ω
). Stubs to substations should be
avoided.
Summary of Contents for AIMB-250F-00B1
Page 25: ...User s Manual AIMB 250 User s Manual 25 2 Hardware Configuration...
Page 26: ...AIMB 250 Series 26 AIMB 250 Series User s Manual 2 1 Product Overview...
Page 60: ...AIMB 250 Series 60 AIMB 250 Series User s Manual 3 BIOS Setup...
Page 75: ...User s Manual AIMB 250 User s Manual 75 3 5 4 3 Super IO Device...
Page 88: ...AIMB 250 Series 88 AIMB 250 Series User s Manual 5 Mechanical Drawing...
Page 89: ...User s Manual AIMB 250 User s Manual 89 Unit mm...
Page 90: ...AIMB 250 Series 90 AIMB 250 Series User s Manual Appendix A AWARD BIOS POST Messages...