11
ADAM-6700 User Manual
Chapter 2
W
iring
and
Settings
2.1.2
Application Wiring
Analog Input and Digital Output Wiring
The gateway supports the voltage and current input. Before connecting the voltage or
current input, ensure that the switch and input range settings of the web utility are set
to the correct value.
Figure 2.1 Current/Voltage Input Switch Setting
Figure 2.2 Digital Output and Analog Input Wiring
SW1
SW2
AI Channel
Ch0
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
Ch7
ON
Current input mode
OFF(default)
Voltage input mode
Summary of Contents for ADAM-6700 Series
Page 1: ...User Manual ADAM 6700 Series Compact Intelligent Gateway with I O...
Page 4: ...ADAM 6700 User Manual iv...
Page 7: ...Chapter 1 1 Product Overview...
Page 14: ...ADAM 6700 User Manual 8...
Page 15: ...Chapter 2 2 Wiring and Settings...
Page 21: ...Chapter 3 3 System Configuration Advantech has developed a web portal for configuring the...
Page 37: ...Chapter 4 4 Node RED Program...
Page 41: ...Chapter 5 5 C Language APIs...
Page 43: ...37 ADAM 6700 User Manual Chapter 5 C Language APIs...