background image

iii

Product Warranty (2 years)

Advantech warrants to you, the original purchaser, that each of its prod-
ucts will be free from defects in materials and workmanship for two years 
from the date of purchase.
This warranty does not apply to any products which have been repaired or 
altered by persons other than repair personnel authorized by Advantech, 
or which have been subject to misuse, abuse, accident or improper instal-
lation. Advantech assumes no liability under the terms of this warranty as 
a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous test-
ing, most of our customers never need to use our repair service. If an 
Advantech product is defective, it will be repaired or replaced at no 
charge during the warranty period. For out-of-warranty repairs, you will 
be billed according to the cost of replacement materials, service time and 
freight. Please consult your dealer for more details.

If you think you have a defective product, follow these steps:
1.

Collect all the information about the problem encountered. (For 
example, CPU speed, Advantech products used, other hardware 
and software used, etc.) Note anything abnormal and list any 
onscreen messages you get when the problem occurs.

2.

Call your dealer and describe the problem. Please have your man-
ual, product, and any helpful information readily available.

3.

If your product is diagnosed as defective, obtain an RMA (return 
merchandize authorization) number from your dealer. This allows 
us to process your return more quickly.

4.

Carefully pack the defective product, a fully-completed Repair and 
Replacement Order Card and a photocopy proof of purchase date 
(such as your sales receipt) in a shippable container. A product 
returned without proof of the purchase date is not eligible for war-
ranty service.

5.

Write the RMA number visibly on the outside of the package and 
ship it prepaid to your dealer.

Summary of Contents for ADAM-6521 Series

Page 1: ...ADAM 6521 Series Industrial Switches with 4 10 100 Mbps Ethernet Ports and 1 Fiber Port User Manual...

Page 2: ...ten permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reli able However Advantech Co Ltd assumes no responsibility for its use nor for any infringements...

Page 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Page 4: ...dio communications Opera tion of this equipment in a residential area is likely to cause harmful inter ference in which case the user will be required to correct the interference at his own expense Te...

Page 5: ...9 Figure 2 1 Bottom 9 Figure 2 2 Top 9 Figure 2 3 Front 9 2 3 Mounting the Module 10 2 3 1 Choosing a Mounting Method 10 Figure 2 4 Wall Mounting 10 Figure 2 5 Attaching DIN Rail Bracket 11 Figure 2...

Page 6: ...ADAM 6521 Series User Manual vi...

Page 7: ...2 CHAPTER 1 Overview This chapter gives an overview of ADAM 6521 modules Sections include Introduction Features Specifications Ordering Information...

Page 8: ...5 C The above functions make the ADAM 6521 modules more stable and reliable so they are especially suitable for industrial environ ments that require Ethernet networking such as semiconductor factorie...

Page 9: ...ber port with SC ST connector Supports full half duplex flow control Supports MDI MDI X auto crossover Provides broadcast storm protection Embedded with a switch controller supports auto negotiation E...

Page 10: ...SC type fiber connector ADAM 6521 ADAM 6521S or 1 x ST type fiber connector ADAM 6521 ST LED Indicators Power Link 100Base FX 100 10M Ethernet Power Power Connectors 2 pin removable screw terminal Po...

Page 11: ...strial Switch with 4 10 100 Mbps Ethernet Ports 1 Single mode SC Type Fiber Optic Port Environment Operating Temperature 10 65 C 14 149 F Stack 10 60 C 14 140 F Storage Temperature 20 80 C 4 176 F Ope...

Page 12: ...ADAM 6521 Series User Manual 6...

Page 13: ...CHAPTER 2 Installation In this chapter you will be given an overview of the ADAM 6521 series hardware installation procedure Sections include LED Indicators Dimensions Mounting the Module Connections...

Page 14: ...dicator Color Status Description Power Green On Power is on Green Off Power is off Link 100BASE FX Green Orange On Connected to network Green Orange Flashing Networking is active Green Orange Off Not...

Page 15: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Bottom Figure 2 2 Top Figure 2 3 Front...

Page 16: ...the ADAM 6521 modules can be Fixed to a wall Fixed to a DIN Rail Piggyback Stacked Panel Mounting ADAM 6521 modules can be attached to a wall using the included brack ets Each bracket comes with four...

Page 17: ...to the ADAM mod ule Because ADAM 6521 modules use special hex head slotted shoulder screws the tops of the screws will be even with the front of the module Snap the module onto the DIN rail Figure 2...

Page 18: ...s via a two pair straight through cable or crossover cable The connection can be made from any port on ADAM 6521 modules MDI X to other hubs or switches either by either an MDI X port or uplink MDI po...

Page 19: ...Power Connection You should take the following steps to connect ADAM 6521 modules to a power supply 1 Connect the power cable to a 2 pin connector 2 Connect the power cable to a power adapter Figure...

Page 20: ...ADAM 6521 Series User Manual 14...

Reviews: