Page 1: ...User Manual ADAM 2000 Series Wireless Sensor Network Data Acquisition Modules...

Page 2: ...ation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers n...

Page 3: ...the dealer or an experienced radio TV technician for help CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use...

Page 4: ...er outlet socket must be located near the equip ment and must be easily accessible 5 Keep this equipment away from humidity 6 Put this equipment on a reliable surface during installation Dropping it o...

Page 5: ...THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT 22 CAUTION...

Page 6: ...ADAM 2000 Series User Manual vi...

Page 7: ...son Table 6 1 3 Dimensions 7 Figure 1 4 ADAM 2000 Series Dimensions 7 1 4 Mounting 8 1 4 1 Panel Mounting 8 Figure 1 5 Panel Mounting Dimensions 8 1 4 2 DIN rail Mounting 9 Figure 1 6 Fixing ADAM 2000...

Page 8: ...the virtual COM port 34 Figure 4 5 Search the COM port for the ADAM 2000 devices 34 Figure 4 6 Searching the network dialog 35 Figure 4 7 Searching the ADAM 2000 coordinators 35 Figure 4 8 ADAM 2000 d...

Page 9: ...bus ID Table of ADAM 2000 series 56 B 2 1 ADAM 2520Z 56 Table B 2 ADAM 2520Z Function Table 56 B 2 2 ADAM 2510Z 57 Table B 3 ADAM 2510Z Function Table 57 B 2 3 ADAM 2017Z 57 Table B 4 ADAM 2017Z Funct...

Page 10: ...ADAM 2000 Series User Manual x...

Page 11: ...Chapter 1 1 Understanding Your System...

Page 12: ...I O Please refer to Figure 1 1 for a brief overview of the ADAM 2000 system architecture Figure 1 1 ADAM 2000 Series System Architecture Figure 1 2 ADAM 2000 Series Outdoor Range Distance 1 1 1 IEEE...

Page 13: ...t maintenance Therefore power consumption taken into con sideration during its design The ADAM 2000 not only follows the IEEE 802 15 4 standard for low power consumption wireless communication but als...

Page 14: ...inance and CO2 concentration then the signals can be apply to your application 1 1 8 Advantech Software Alignment As with all other ADAM devices the ADAM 2000 integrates into the ADAM NET Util ity the...

Page 15: ...emperatures above 70 C for a long period If you need to operate the device in temperatures exceeding those stated contact your nearest sales agent Table 1 2 LED Indicator Definitions Name Color LED St...

Page 16: ...e into consideration the topology that will be used since different topologies have different characteristics The ADAM 2000 series provides start tree and mesh topologies No further configu ration is...

Page 17: ...7 ADAM 2000 Series User Manual Chapter 1 Understanding Your System 1 3 Dimensions Figure 1 4 ADAM 2000 Series Dimensions...

Page 18: ...e field site with the following method 1 4 1 Panel Mounting Each ADAM 2000 Module is packed with a plastic panel mounting bracket Users can refer the dimensions of the bracket to configure an optimal...

Page 19: ...the ADAM 2000 module with the DIN rail adapter as Figure 3 2 Then secure it on the DIN rail as Figure 3 3 If you mount the module on a rail you should also consider using end brackets at each end of...

Page 20: ...between router or end device 1 5 1 1 External Power Input Although the ADAM 2000 systems are designed for a standard industrial unregulated 24 VDC power supply they accept any power unit that supplie...

Page 21: ...Note The batteries will not be charged when using external input power 1 5 2 I O Module Wiring The system uses a plug in screw terminal block as the interface between I O mod ules and external device...

Page 22: ...00 Series User Manual 12 Figure 1 9 RS 422 485 and USB interface of ADAM 2520Z Figure 1 10 Wiring Diagram for ADAM 2520Z Figure 1 11 TTL Input Wiring Diagram Figure 1 12 Contact Closure Input Wiring D...

Page 23: ...Chapter 2 2 Selecting Your Hardware...

Page 24: ...to translate data packets between two different networks The router is optional in a PAN The major function of a router is to repeat the wire less signal to improve the LQI With routers a PAN can be...

Page 25: ...ns Photoelectric eyes Limit switches Circuit breakers Proximity switches Level switches Motor starter contacts Relay contacts Thumb wheel switches Input modules sense On Off signals or Open Closed sig...

Page 26: ...r reading the real time status of ADAM 2000 series modules anywhere without any engineering effort there is a lot of third party Modbus software available To integrate ADAM 2000 series I O with HMI Hu...

Page 27: ...Chapter 3 3 Installation Guide...

Page 28: ...Power Supply for ADAM 2000 Series 10 30 VDC Unregulated 3 1 3 Perform a Wireless Sensor Network Coordinator Router and End Device are three basic elements of the Wireless Sensor Network Each of them h...

Page 29: ...de is the basic element to acquire the physical signals and data from I O sensor and even communication interface It can be designed for many different functions and is possible for standalone applica...

Page 30: ...for further operations Initial Mode The Initial Mode is for user to configure parameters of the ADAM 2000 devices While the device is in the Initial Mode Status LED turns on 1 Push the Mode Switch to...

Page 31: ...Pair ID 1 4 Status LED turns on Error LED blinks 5 Level Index turns on to indicate Pair ID 1 Pair ID needs to be properly configured if there are coordinators For advanced settings please refer to se...

Page 32: ...through ADAM NET Utility for Normal Mode opera tion For detailed operation and functionality of ADAM NET Utility please refer to Chapter 5 Push the Mode Switch to the Normal position to reboot the de...

Page 33: ...sh mechanism Please refer to the following flowchart for the overview of ADAM 2000 installation configuration and operation Figure 3 2 ADAM 2000 Installation Chart Install power of ADAM 2000 devices A...

Page 34: ...rnal USB power Configured ready for Normal Mode Initial Mode Status LED turns on Error LED blinks Normal Mode Status LED turns off Error LED blinks Error LED turns off Successfully host a PAN with def...

Page 35: ...oting All LEDs turn On Green LED turns on while powering by external power Configured ready for Normal Mode Initial Mode Status LED turns on Normal Mode Status LED turns off Error LED blinks Error LED...

Page 36: ...n Green LED turns on while powering by external USB power Configured ready for Normal Mode Initial Mode Status LED turns on Normal Mode Status LED turns off Error LED blinks Error LED turns off Succes...

Page 37: ...Index in the front panel will turn on to indicate the level of battery power 3 3 3 Associating Devices Routers and End Devices must have to associate with corresponding Pair ID Coordi nator in Initial...

Page 38: ...er the change Pair ID mode 2 Status LED blinks 3 Level Index LED turns on to indicate Pair ID 4 Press the Function Button once to change Pair ID 5 Press and hold the Function Button for over 3 seconds...

Page 39: ...Chapter 4 4 Software Configuration Guide...

Page 40: ...tion You can find the Utility installation file in the CD with your mod ule or on our website at http www advantech com and click the Download Area under Service Support to get the latest version of t...

Page 41: ...n Section 5 3 2 2 Add Devices to Group You can add ADAM 2000 modules to your favorite group by this option You need to select the device you want to add in the Mod ule Tree Display area it will be des...

Page 42: ...ou can define which devices listed in the three categories above into your per sonal favorite group This will make you easier to find your interested modules Right click on the ADAM device item under...

Page 43: ...DAM 2000 Series ADAM NET Utility Support If the user wants to use USB cable to connection with ADAM utility on PC they need to install USB chip driver in CD Step 1 Connect a USB cable between the ADAM...

Page 44: ...select the Refresh Subnode to search the virtual COM port on the host PC Figure 4 4 Search the USB interface ADAM 2000 devices on the host PC for the virtual COM port Click the COM port then click rig...

Page 45: ...2000 Coordinators from Modbus ID 241 to 244 please refer to the Appendix B 2 for more information Figure 4 6 Searching the network dialog The ADAM 2000 coordinators will be listed on the Tree View of...

Page 46: ...sts routers under the coordinator Gateway The ADAM End Device folder lists end devices also under the coordinator Gateway Figure 4 8 ADAM 2000 devices lists on the Tree View and Information page Press...

Page 47: ...nd List View of End Device page The page contains an overview of the end devices and the status Figure 4 9 The overview of ADAM 2000 end devices Folder of ADAM Router lists the ADAM 2000 routers in Tr...

Page 48: ...the ADAM 2520Z if there is any upgrade firmware from the Advantech 2 User can modify the COM port parameters for Normal Mode Figure 4 11 Information page of ADAM 2520Z Select the Wireless Configuratio...

Page 49: ...rations and Device Status In the Information page users can download the firmware to the ADAM 2510Z if there is any upgrade firmware from the Advantech Figure 4 13 Information page of ADAM 2510Z In th...

Page 50: ...15 The Device Status page of the ADAM 2510Z 4 3 1 3 End Device ADAM 2017 ADAM 2031Z ADAN 2051Z ADAM 2051PZ Click the ADAM 2051Z it will display the Information and Wireless Configuration pages In the...

Page 51: ...ommunication in Nor mal Mode 2 The Duty Cycle is the transmit interval of the device the device can update the data by 1 second to 1 day Figure 4 17 Wireless Configuration page of ADAM 2051Z In the De...

Page 52: ...ated chan nel or sensor Figure 4 19 The Signal page of the ADAM 2051Z Click the ADAM 2031Z it will display the Information and Wireless Configuration pages Figure 4 20 Information Page In the Informat...

Page 53: ...PAN for wireless communication in Normal Mode 2 The Duty Cycle is the transmit interval of the device the device can update the data by 1 second to 1 day Figure 4 21 Wireless Configuration Page In th...

Page 54: ...and the Topology also lists the relations between devices in advance Click the Topology the relations of ADAM 2000 devices will be illustrated in the Topology page There are three components with mode...

Page 55: ...unction allows user to put a picture on the background and drag the compo nents to any positions of the background With the function user can easily maintain and check the status of the ADAM 2000 netw...

Page 56: ...ADAM 2000 Series User Manual 46...

Page 57: ...Appendix A A Module Introduction...

Page 58: ...4 GHz 2 4835 GHz Channels 11 26 RF Data Rate 250 Kbps Transmit Power 19 1dBm Receiver Sensitivity 97dBm Antenna Type Dipole Antenna Gain 2 dBi Outdoor Range 1000 m Topology Star Tree Mesh Function Ro...

Page 59: ...19 1dBm Receiver Sensitivity 97 dBm Antenna Type Dipole Antenna Gain 2 dBi Outdoor Range 1000 m Topology Star Tree Mesh Network Capacity 32 nodes Routers End Devices Max Routers Scale 6 6 pcs Function...

Page 60: ...mission Interval 1 second 24 hours Function End Device General Connector 1x plug in terminal block 14 22 AWG Power Input Unregulated 10 30 VDC Battery Input 2 x AA Alkaline Power Consumption 0 3 W 24...

Page 61: ...2 AWG Power Input Unregulated10 30 VDC Battery Input 2 x AA Alkaline Power Consumption 0 3 W 24 VDC 420 uW 3 VDC 1 minute Tx interval with 2 AA Batteries 240 uW 3 VDC 2 minute Tx interval with 2 AA Ba...

Page 62: ...e Mesh Transmission Interval 1 second 24 hours Function End Device General Connector 1x plug in terminal block 14 22 AWG Power Input Unregulated 10 30 VDC Battery Input 2 x AA Alkaline Power Consumpti...

Page 63: ...m Receiver Sensitivity 97 dBm Antenna Type Dipole Antenna Gain 2 dBi Outdoor Range 1000 m Topology Star Tree Mesh Transmission Interval 1 second 24 hours Function End Device General Connectors 1x Plug...

Page 64: ...ADAM 2000 Series User Manual 54...

Page 65: ...Appendix B B ADAM 2000 Series Functions...

Page 66: ...Function code Register Address and Value must be properly configured In the session you can find the detail Modbus information of the ADAM 2000 series B 2 1 ADAM 2520Z Wireless Sensor Network Modbus R...

Page 67: ...1840 counts 5 seconds per count 0xFFFF Over 3 days Table B 4 ADAM 2017Z Function Table Address 4X Description Attribute Value 00001 Channel 1 Read 0x0000 0xFFFF Selected input range 00002 Channel 2 Re...

Page 68: ...Bit1 1 External Power Input 20002 LQI Read 0x0000 0x00FF 0x0000 No Signal 0x00FF Excellent 20003 Battery Level Read 0x0000 Low 0x4000 Poor 0x8000 Normal 0xC000 Good 0xFFFF Excellent 20004 Device Inac...

Page 69: ...t0 0 Off Bit0 1 On 00005 DI 4 Read Bit0 0 Off Bit0 1 On 00006 DI 5 Read Bit0 0 Off Bit0 1 On 00007 DI 6 Read Bit0 0 Off Bit0 1 On 00008 DI 7 Read Bit0 0 Off Bit0 1 On 20001 Module Status Read Bit0 0 I...

Page 70: ...Bit0 1 On 00005 DI 4 Read Bit0 0 Off Bit0 1 On 00006 DI 5 Read Bit0 0 Off Bit0 1 On 00007 DI 6 Read Bit0 0 Off Bit0 1 On 00008 DI 7 Read Bit0 0 Off Bit0 1 On 20001 Module Status Read Bit0 0 Initial M...

Page 71: ...Appendix C C Troubleshooting...

Page 72: ...side button 5 times to change the Pair ID to associate with the specified Pair ID coordinator Q4 Why are all the amber LEDs on coordinator blinking while operating in initial mode A4 Four Pair ID can...

Page 73: ...n use ADAM utility to get ADAM 2000 system parameters then SCADA soft ware can connect them according these parameters 5 ADAM 2000 models do not support the My Favorite function in the ADAM util ity 6...

Page 74: ...brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2011 Notice The changes or modifications not expressly approved by the party responsible...