NOTE:
All shadowed lines in the following table are for commands not applicable for these
units
TABLE 11
: RS-232 MENU ITEM DEFINITION
Item
Description
S/N
Serial Number of the SSPB Block Up-Converter
Version number of the main controller board software within the SSPB that
is connected to the RS-232 port of the PC
Soft
Unit Pos
Indicates the position of the unit (A or B) in the redundant system
Indicates the name of the unit (SSPB A for Block Up-Converter A, or SSPB
B for Block Up-Converter B)
Name
MAC
Indicates the serial address of the Monitor and Control of the unit (in hex)
Indicates current consumption at 12 V DC and at 24 V DC of the unit, in
amperes
Cur12/24
TxF
Transmission frequency (not applicable for these units)
Indicates the LO Frequency of the Block Up-Converter transmission path,
in MHz
TxF Shift
Indicates the Forward Power of the Block Up-Converter (the transmission
path output power) in dBm
FPWR
TxGain
Indicates the transmission Gain in dB
Tx Stat
Indicates the transmission status (On or Mute)
Indicates the Reverse (reflected) Power of the unit (the transmission path
reflected power) in dBm. Any value under 22 dBm is indicated as <22.0
dBm.
RPWR
Temp HS
Hot Spot Temperature of the unit in degrees Celsius.
PS12/24
Power Supply voltage in V for 12 V and for 24 V Power Supplies
Elaps Time
Elapsed functioning time (days:hours) from the first start-up of the unit
ALC Status
ALC Status (ON or OFF)
Ref
AUTO (internal): indicates that the unit is using internal reference
36