IX.  Manufacturer’s Product Warranty

 

 

Advantage Controls warrants units of its manufacture to be free of defects in material or 

workmanship.  Liability under this policy extends for 24 months from date of installation.  Liability is limited 

to repair or replacement of any failed equipment or part proven defective in material or workmanship upon 

manufacturer’s examination.  Removal and installation costs are not included under this warranty.  

Manufacturer’s liability shall never exceed the selling price of equipment or part in question.

 

Advantage disclaims all liability for damage caused by its products by improper  installation, 

maintenance, use or attempts to operate products beyond their intended  functionality, intentionally or 

otherwise, or any unauthorized repair.   Advantage is not  responsible for damages, injuries or expense 

incurred through the use of its products.

 

The above warranty is in lieu of other warranties, either expressed or implied.  No agent of ours is 

authorized to provide any warranty other than the above.

30 Day Billing Memo Policy 

 

 

Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service 

with minimum downtime.  If your unit malfunctions, call 1-800-743-7431, and provide our technician with 

Model and Serial Number information.  If we are  unable to diagnose and solve your problem over the phone, 

a fully warranted replacement unit will be shipped, usually within 48 hours, on a 30 Day Billing Memo.

 

This service requires a purchase order and the replacement unit is billed to your regular account for 

payment.

 

The replacement unit will be billed at current list price for that model less any applicable resale 

discount.  Upon return of your old unit, credit will be issued to your account if the unit is in warranty.  If the unit 

is out of warranty or the damage not covered, a partial credit will be applied based upon a prorated 

replacement price schedule dependent on the age of the unit.  Any exchange covers only the controller 

or pump.  Electrodes, liquid end components and other external accessories are not included.

FCC Warning

This equipment generates and uses radio frequency energy and if not installed and used properly, 

that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio 

communications.  It has been type tested and found to comply with the limits for a class A computing 

device pursuant to subpart J of part 15 of FCC Rules, which are designed to provide reasonable 

protection against such interference when operated in a commercial or industrial environment. 

Operation of this equipment in a residential area is likely to cause interference in which case the user, 

at his own expense, will be required to take whatever measures necessary to correct the interference.

Summary of Contents for NANO-N

Page 1: ... mA Input Installation Maintenance Repair Manual Advantage Controls 4700 Harold Abitz Dr Muskogee OK 74402 Phone 918 686 6211 Fax 888 686 6212 www advantagecontrols com email support advantagecontrols com 4 2019 ENTER ...

Page 2: ...nstallation Mounting Instructions 4 Electrical Wiring 4 Relay Cards 4 Logic Cards 5 IV Front Panel Description 6 V System Operation Overview 6 Description of Menus 6 VI Maintenance 7 VII Troubleshooting 7 VIII NanoTron mA Menu Map 8 IX Warranty 30 Day Billing Memo Policy 10 ...

Page 3: ...her external devices via two control relay outputs The pulse output can pace a metering pump or convert a mA flow rate into contact style water meter pulses like used in a MegaTron Follow the steps below to program the Pulse Out based on the mA range of the flow device using an example of 500 gpm as the max 20mA signal 1 In the Configure menu set the Pulse output to ON 2 In the Configure menu defi...

Page 4: ...side the controller even when the power switch on the front panel is in the OFF position Never open the front panel without first disconnecting power from the outlet Prewired controllers are supplied with an 8 foot 18 AWG power cord with USA style plug A 1 Phillips driver is required to open the front panel 2 Low voltage signal wires probes flow switch water meter etc should never be run in condui...

Page 5: ...al 24 VDC Power Output J2 NanoTron N Logic Card Contrast Power 1 2 3 4 5 ON OFF If the mA OUT Power switch is on INT the unit s internal 24 VDC is applied to the output If set for EXT the external loop out power supplied is used on the output Pulse Out mA OUT Flow Switch WM or Dig In mA IN Internal 24 VDC Ext Out Loop Power Input Device Input Device Jump from 24 to mA IN Wiring for two wire input ...

Page 6: ...ill read system values If an alarm is present the display flashes with the alarm status The Run menu will display values such as day time date and other values depending upon the features present on the unit The unit will automatically return to the Run mode if no keys are pressed for three minutes Menu This mode is used to make adjustments to settings and readings on the controller To access the ...

Page 7: ...g needs to be done less often VII Troubleshooting The Advantage NanoTron controller is designed for many years of trouble free operation Should a problem occur refer to the following chart to help identify the problem If replacement is required follow the procedures listed in the Warranty and Factory Service portion of this manual SYMPTOM POSSIBLE CAUSE SOLUTION False reading Bad or dirty electrod...

Page 8: ...Password 0000 Flow Sw Close DigIn W Meter Feed OK w Ctrl No Feed No Flow Pulse ON 4 20 Output 4 mA 000 0 Sim 4mA OF 20mA 999 9 Sim 20mA OF Set 4 and 20 out at desired sensor readin Sim 4 and 20 will force outp to either 4 or regardless of reading 4mA applied N 4mA In 04350 20mA applied N 20mA In 21350 Press Enter only if a 4mA or 20mA signal is being received when in those calibration screens Sele...

Page 9: ...ate is sensor reading for high pulse rate LoRate 000 0 Set 4 and 20mA out at desired sensor reading Sim 4 and 20mA will force output to either 4 or 20 regardless of reading Select if Pulse Output of mA input is on off Set the decimal for displayed numerical format and the 4mA and 20mA for what the value of that range desired at those two mA values CAL 20 2948 CAL 4 0590 Set Default N Increase the ...

Page 10: ...n If we are unable to diagnose and solve your problem over the phone a fully warranted replacement unit will be shipped usually within 48 hours on a 30 Day Billing Memo This service requires a purchase order and the replacement unit is billed to your regular account for payment The replacement unit will be billed at current list price for that model less any applicable resale discount Upon return ...

Page 11: ...11 Notes ...

Page 12: ...ollers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems Get the Advantage 5 4 3 2 1 ENTER HELP 5 4 3 CHANGE RUN SET UP 0 9 8 2 1 7 6 HOME BACK 3 4 5 2 1 8 9 0 7 6 SET UP RUN CANCEL HELP BACK ENTER HOME ...