![Advanjet HV-2100 Jet Setup And Operation Download Page 14](http://html.mh-extra.com/html/advanjet/hv-2100-jet/hv-2100-jet_setup-and-operation_2856327014.webp)
3.4
Install the Diaphragm and Nozzle Plate
Material inside the applicator can be near setpoint temperature.
To avoid severe burns, wear protective gloves.
1.
Turn the main power ON.
2.
Set the jet pressure to 40 psi (.28 MPa).
3.
On the Advanjet controller home screen, tap
Jet
to OPEN the jet.
4.
Note the
rectangular
grooves on the
heater block that
align with the
grooves on the
diaphragm.
5.
Gently press the
diaphragm into the
heater block until the
diaphragm pin is
inserted in the center
and the rectangular
grooves are firmly in
place.
6.
Note that the
heater block has
two pins that align
with two holes in
the nozzle plate.
7.
Use the pins to align the
nozzle plate on the heater
block. The nozzle plate O-
ring faces up, and the fluid
barb faces the fluid syringe.
8.
Tighten
the two
embedded screws
with a 3-mm hex
driver. Do not over-
tighten; it is possible
to strip the screws.
An optional torque
wrench is available
for this purpose (P/N
NT09-2500).
9.
Before installing the fluid syringe, CLOSE the jet.
ALIGN
THE
GROOVES
ALIGN PINS TO HOLES
NOZZLE
PLATE
O-RING
FACES UP
FLUID BARB
FACES
SYRINGE
Page 14 of 22
Advanjet HV-2100 Jet Setup and Operation
3A6244A