3.7.8
Tuck the Cables
Press the main air valve cable
into the slot in the back of the
top cover, followed by the
heater/melter cable. Fasten with
a cable tie as shown.
3.7.9
Trim the Cables
Trim the cable tie end and press
the fastener until it is fully seated
in the top cover slot. Carefully
tuck the wires and connectors
into the top cover.
3.7.10 Connect the Air Valve
Attach the air valve cable
connector as shown.
Carefully tighten the screw.
NOTICE
Over-tightening can
easily break this plastic.
3.7.11 Position Mounting
Plate
Use the alignment pins to
position the mounting plate.
Take care that the cables
are not pinched between the
mounting plate and
manifold.
3.7.12 Attach the Mounting
Plate
Locate the three mounting plate
screws that were set aside.
Apply Loctite 242 to the tips and
attach as shown.
3.7.13 Attach the Dovetail
Plate
Locate the four dovetail plate
screws that were set aside.
Apply Loctite 242 to the tips of
and attach as shown.
Continue to the next section—Set the Jet Hammer Gap.
Page 24 of 28
Advanjet HM-2600 Hotmelt Jet Maintenance and Repair
3A6328A