Summary of Contents for Axis AX-ASW-16

Page 1: ...www advancedco com Switch LED Modules 24V 485 B A PSU MONITOR 1 2 3 4 5 6 7 ON AX ASW 16 AX I O 48 AX LED16RY AX LED32R AX LED32Y...

Page 2: ...S 7 3 2 485 COMMS EOL DISABLE PSU MONITOR 2 DIP SWITCHES 7 3 2 1 485 Comms P BUS EOL 7 3 2 2 Disable PSU Power Supply Unit Monitor 8 4 MODULE WIRING 8 4 1 24 VDC POWER WIRING 8 4 2 485 AX SERIES P BUS...

Page 3: ...nts etc The AxisAX Switch LED Modules are extremely flexible and easy to configure program utilizing the Advanced PC NeT field configuration tool which works in a Windows environment Switches can be p...

Page 4: ...Modules can be mounted into any available inner AX CTL 1 outer door aperture of an AxisAX enclosure see figure 1 AX CTL 1 AX CTL 1V 2V or 4V AX CTL 1L 2 or 4 AX Command Center 3x5 AX Command Center 3...

Page 5: ...e see figure 2 2 2 AX LZA Cabinet Mounting In addition to being mounted in an AxisAX enclosure Switch LED Modules can also be mounted in an Advanced local zone annunciator cabinet Advanced has three s...

Page 6: ...ided with the AX LZA CAB 2 3 AX I O 48 Other Cabinet Mounting In addition to being mounted in cabinets previously mentioned the AX I O 48 Switch LED Driver Module can also be installed in an Advanced...

Page 7: ...or module addressing each Switch LED Module has two additional DIP switches DIP switch 6 and 7 DIP Switch 6 is for activating an onboard resistor to allow for AX CTL base card P BUS RS485 end of line...

Page 8: ...see figure 6 Note Normally when the Switch LED Module is mounted to an aperture opening slot location in an AxisAX panel power for the module is obtained from AUX 2 of the AX CTL base card If the pow...

Page 9: ...ications can be daisy chained from the first Switch LED Module to the next module then from that module to the following module etc 4 3 24 VDC 485 AX Series P BUS Daisy Chain Wiring When utilizing mul...

Page 10: ...ormally closed trouble relay contact of the Listed power supply see figure 10 4 5 AX I O 48 Input Output Wiring In addition to the power supply and P BUS wiring each AX I O 48 Switch LED Driver Module...

Page 11: ...the Ax4 CTL 4 and double click the associated peripheral bus address 26 thru 41 module address 0 thru 15 respectively Correlation of the switch LED module address is DIP switch address 0 peripheral b...

Page 12: ...s of any type can be added to a single AxisAX AX CTL base card P BUS RS485 serial communications To program the specific peripheral bus Switch LED Module click on the peripheral bus module and then c...

Page 13: ...www advancedco com www advancedco com 13 Figure 13 AX ASW 16 Programming Area Screen Figure 14 AX I O 48 Programming Area Screen...

Page 14: ...n area will open up on the bottom left hand side of the screen Within the LED Operation area you should assign a Function Description for the LED After assigning a Function Description click on the Un...

Page 15: ...anted to also program a zone trouble LED you would click on the yellow LED the yellow LED would illuminate and the LED Operation area will open up on the bottom left hand side of the screen Within the...

Page 16: ...a disablement you could program this functionality within the Secondary Activation Operating Method If you want to distinguish a disablement from a trouble you could program the LED for a Secondary A...

Page 17: ...Point Details area on the bottom left hand side of the screen Within the Point Details area for the specific button switch or input you should assign a location text for example Zone 1 Bypass After a...

Page 18: ...ected you would input the zone number you d like to disable within the Disablement Zone number area default is zone 1 5 3 Buzzer Operation Programming Each Switch LED Module has a programmable buzzer...

Page 19: ...osure or not simply slide the previously installed label out of the slide in pocket located at the top of the module and slide the installation specific customized label into the pocket see figure 16...

Page 20: ...uts Normally closed N C contact monitoring Outputs LED AX ASW 16 LED AX LED16RY LED AX LED32R LED AX LED32Y LED Output AX I O 48 Buzzer 48 programmable LEDs 16 Green 16 Red 16 Yellow 32 programmable L...