background image

5

Call Box Specifications

Without Mounting Bracket: 

 

With Mounting Bracket:

Height:  5.0625”    

 

Height:  5.25”

Width: 

3.25”  

 

 

Width: 

3.4375”

Depth:  1.375”    

 

Depth:  1.625”

Weight:  5.7 oz.    

 

Weight:  7.1 oz.

Battery:   

3.6V lithium

Humidity:  

Up to 90% non-condensing

Temperature: 

20° F to 140° F

Freq. Range: 

902-928 MHz

Auto Check-In: 

3 minutes

The AW-NCB4100(W) is not water resistant – do not submerge in water.

Call Box Cleaning Recommendations

Never use strong cleaning chemicals to clean the surface area of two-

way radios or call boxes. Some examples would be: acetone, bleach, 

window cleaner, degreasers, hand sanitizers, nail polish remover or like 

products. Referencing the above cleaning procedures; Advanced Wireless 

Communications, Inc. does NOT imply that any of these cleaning procedures 

provided is effective in removing or killing potential contaminants or viruses from 

the radio surface. Rather, these recommendations are intended to provide the 

radio user with acceptable alternatives for a cleaner physical environment.

Preferred Cleaning Method 

– 

Use a warm, damp cloth (water only) to wipe all surface areas of the call box. 

The cloth should be damp only, not dripping water. Never hold the call box 

under a running water faucet or submerge in water. After wiping, if moisture is 

seen on the surface of the call box, wipe with a dry cloth to speed drying.

Acceptable Cleaning in Moderation 

Use a mild dish soap and warm water mix, thoroughly submerge the cloth in the 

soap and water solution. Remove the cloth and wring all water out of the cloth. 

The cloth should be damp only, not dripping. Never hold the call box under a 

running water faucet or submerge in water. Wipe all surface areas of the call 

box. After wiping, if moisture is seen on the surface of the call box, wipe with a 

dry cloth to speed drying.

Aggressive Cleaning Method 

Note:

 

Over time, this method can cause undesirable cosmetic effects to the 

label and adhesive areas. It can also cause discoloration to plastics.

Use an over the counter, 75% Isopropyl alcohol concentration to dampen a 

cloth. Damp only, not dripping alcohol. Wipe all surface areas of the call box. 

Alcohol residue will dry quickly.

NEVER apply the 75% Isopropyl alcohol directly to the surface area of the 

call box. Never submerge call box in alcohol.

Summary of Contents for AW-NCB4100

Page 1: ...User Manual AW NCB4100 W Wireless Nurse Call Box ...

Page 2: ...e call box becomes part of the ODIN Care system infrastructure and is an initiator that provides activation and deactivation of the ODIN Care system The AW NCB4100 W is white in color and has a gray faceplate label Status LED s are located in the upper left hand corner of the call box and provide easy visual confirmation of the call box status Product Summary This manual should be read to ensure t...

Page 3: ...ox Bed Cord Port One The left port of the call box will activate the primary alarm transmission Bed Cord Port Two The right port of the call box will activate the secondary alarm transmission If a bed cord is pulled from the call box the call box will activate as if the button has been pressed The call box will not be able to be reset until the bed cord and breakaway module have been reinstalled i...

Page 4: ... Remove both Magnetic Breakaway Jumper Plugs To remove a Magnetic Breakaway Jumper Plug Use a small screwdriver or equivalent to access the small opening at the bottom center of the call box Magnetic Breakaway Port Gently pry outward to remove the Jumper Plug 2 Jumper Plug Removal Access Holes 900294 Magnetic Breakaway Module 1 4 Phono Jack 900274 Magnetic Breakaway Jumper Plug 900293 Magnetic Bre...

Page 5: ...CB4100 W To Mounting Bracket The call box is installed onto the mounting bracket from the top down Line up the back of the call box to the top of the bracket and slide the call box downward The call box will lock into place in the mounting bracket To remove the call box from the mounting bracket press the lock release tab and slide the call box up and out of the mounting bracket Pull Cord Installa...

Page 6: ...y The correct battery replacement must be used Even though the battery is the same size as an alkaline AA battery an alkaline battery WILL NOT work in this call box Multi Function LED Indicator Lights No LED illumination call box is idle Single red flash once per second to indicate an active primary alarm bed port 1 pull cord or button press activation Two short red flashes two per second to indic...

Page 7: ... a warm damp cloth water only to wipe all surface areas of the call box The cloth should be damp only not dripping water Never hold the call box under a running water faucet or submerge in water After wiping if moisture is seen on the surface of the call box wipe with a dry cloth to speed drying Acceptable Cleaning in Moderation Use a mild dish soap and warm water mix thoroughly submerge the cloth...

Page 8: ...Breakaway Module RJ45 900294 Magnetic Breakaway Module phono plug 900273 Mounting bracket Nurse Call Box 900291 Nurse Call Box assembly Restroom configuration 900292 Nurse Call Box assembly Single bed RJ45 Breakaway Module 900295 Nurse Call Box assembly Dual bed RJ45 Breakaway Module 920801 Pull cord white washable 3 foot 920818 Pull cord white washable 5 foot 915722 Rubber Keypad large blue and s...

Page 9: ...703119 2020 Advanced Wireless Communications All rights reserved 952 469 5400 Toll Free 800 475 5852 20809 Kensington Blvd Lakeville MN 55044 8353 www advancedwireless com ...

Reviews: