background image

OVERVIEW 

 
 
The AV102SS intercom system designed to interface directly with the 

Adpro

 fast-scan, 

FastVu and FastTrace Video/Audio transmission systems. It is constructed entirely of 
Stainless Steel for the ultimate in durability and robustness.  
 
It is Vandal-Resistant and weatherproof, making it ideal for use in external public areas 
such as help-points, door and gate access control systems and lift intercoms. 
 
The faceplate and housing have a Grained (illustrated) finish as standard. A highly 
polished finish is available as an optional extra. We also provide a faceplate engraving 
service if required, as an optional extra. 
 
The faceplate is attached to the housing using HEX-PIN, stainless Steel machine screws. 
This prevents the removal of the faceplate without the correct security tool (supplied). 
 
The system comes complete with power supply and audio interface (the AVPSU4) which 
provides audio in and out at industry standard levels, in addition to the 15 pin "D" 
connector for direct connection to Adpro remote transmitters (see specifications on last 
page). 
 
The system may be operated on either balanced-line or single-ended systems. 
 

The intercom unit may be fitted with the following options, if required:- 

 

♦ 

An internal Covert monochrome camera ( Add suffix /CVM to part code ) 

♦ 

An internal Covert colour camera (Add suffix /CVC to part code) 

♦ 

A solid-state audio message system which will give a voice message of up to 16 
seconds when the call button is pressed ( Add suffix /A to part code ). 

 
Where a camera is fitted, the Video output is via an internal video ground-loop isolation 
transformer and utilises a standard 75 Ohm BNC connector. 
 
The unit requires 24 Volts DC power which is normally supplied from the (included) 
interface unit. 
 
All connections are made via 2-part screw terminals, so that the connections can be made 
using just the faceplate Hex-Pin tool (supplied in the kit) and a small, flat-blade 
screwdriver! 
 
An optional switching card (model 102PAIR1) may be fitted to enable two units to be used 
in a master/slave combination, using only a single channel of the ADPRO transmission 
system. This may be used, for example, where an IN/OUT gate requires an intercom on 
both sides of the gate. The advantage of this is that only a single set of wiring is required 
from the equipment room to the master intercom, and then a similar set of wiring between 
the Master and the Slave units, which will normally be only a few metres apart. 
 
 

DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1       1st August 2006         Page 

2

 of 22 

Summary of Contents for AV102SS

Page 1: ...stead Hertfordshire HP2 7DU Telephone 01442 252280 Fax 01442 244578 Email avsl globalnet co uk Website avsl com DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Model AV102SS Stainless Steel Intercom Call Point Installation and Operating Instructions ...

Page 2: ...GRAMS Adpro 15 pin D connector details Page 3 Connecting a single call point via ADPRO transmitter Full diagram Page 5 Connecting a single call point to a local handset only Full diagram Page 6 Single call point via ADPRO transmitter with local AVS handset Full Diagram Page 7 Installing Master Slave switching PCB Page 9 Master Slave switching PCB Connector layout Page 10 Connecting Master Slave un...

Page 3: ...it may be fitted with the following options if required An internal Covert monochrome camera Add suffix CVM to part code An internal Covert colour camera Add suffix CVC to part code A solid state audio message system which will give a voice message of up to 16 seconds when the call button is pressed Add suffix A to part code Where a camera is fitted the Video output is via an internal video ground...

Page 4: ...ot used for others 9 AUDIO COMMON 10 GROUND 11 GENERAL ALARM NORMALLY CLOSED 12 GENERAL ALARM NORMALLY OPEN 13 PTT INPUT FastScan Unused for others 14 DATA D0 FastScan Clock for others 15 DATA D2 FastScan Strobe for others VIEWED FROM FRONT OF ADPRO 15 PIN CONNECTOR 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 NOTE THE ADPRO CONNECTOR IS A CHASSIS MALE PLUG THE CONNECTORS REQUIRED FOR THE CABLE AR...

Page 5: ... the AVPSU4 V OUT and GROUND terminals up to a distance of 250 metres If you require the call point to be further away from the AVPSU4 or if it simply more convenient you may power the call point locally using a 24 Volt DC regulated power supply which should be capable of providing a current output of up to 650mA in which case the power supply output should be connected to the terminals on the cal...

Page 6: ...essage card PCB where fitted U4 MIC GAIN MESSAGE GAIN OUTPUT LEVEL NOTE These controls are shown set to their factory positions and should not require adjustment 800 mA FUSE PB PB OC OC LSP LSP MIC MIC LSP LSP MIC MIC SPARE VIDEO GROUND 12V VIDEO GROUND LOOP ISOLATION TRANSFORMER C14 C11 Solder Dot U1 R7 R13 R19 U2 U3 IC1 9 15 1 8 GROUND CALL INPUT CALL INPUT AUDIO OUT AUDIO OUT AUDIO IN AUDIO IN ...

Page 7: ...NDSET The AV102SS may be used as a stand alone intercom using the AVSHS01 handset This application may only be used with a single intercom call point or a single master slave combination DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 6 of 22 ...

Page 8: ...RO remote transmitters FastScan FastVu or FastTrace If a local handset is required for use during manned hours the system should be connected to the ADPRO transmitter as described previously in this manual with the additional connections made between the rear of the AVPSU4 unit and the handset as shown in the drawing below DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 7 of 22 ...

Page 9: ...ack to unit A COMMON CALL JUMPER The switching card will output the call from each unit when the button is pressed This is done via on board clean contact normally open relays on the switching PCB In order to use the individual call outputs the common call jumper should be set to OFF and the call outputs A B should be wired individually to A CALL and B CALL Refer to the drawing on page 10 labelled...

Page 10: ... or washers then screw an M3 full nut on top of each of the new pillars Place an M3 plain washer on top of these and position the PCB so that the BNC connectors are above the BNC connector on the existing main PCB Place an M3 plain washer on to the studs which now protrude through the new PCB and screw an M3 full nut on to each DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 9 of ...

Page 11: ...manual There is no need for a second AVPSU4 for unit B as the switcher card in unit A provides the power supply and interfacing If the switching card PCB is less than a revision 3 version the call outputs from the PCB unit A and unit B are marked incorrectly on the PCB s silk screen i e the terminals marked A CALL and the terminals marked B CALL are reversed These terminals have been re labelled a...

Page 12: ...DIO OUT 8 AUDIO IN H FROM AVPSU In equipment room MARKED AUDIO OUT 9 AUDIO OUT C TO AVPSU In equipment room MARKED AUDIO IN 10 AUDIO OUT H TO AVPSU In equipment room MARKED AUDIO IN 11 TO UNIT A 0V 12 TO UNIT A IN 13 TO UNIT A OC 14 TO UNIT A OC 15 TO UNIT A I P 16 TO UNIT A I P 17 TO UNIT A O P 18 TO UNIT A O P PAIR PAIR PAIR 19 TO UNIT B 0V 20 TO UNIT B IN 21 TO UNIT B OC 22 TO UNIT B OC 23 TO U...

Page 13: ... WIRING DIAGRAM This diagram shows the wiring for a master slave combination with COMMON CALL enabled and feeding an ADPRO remote transmission system DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 12 of 22 ...

Page 14: ...pto isolated and the audio signals are transformer isolated This provides a high degree of protection against unwanted voltage which may appear on the site cabling and which could otherwise result in damage to the sites security equipment The audio transformers also provide both a balanced line signal path between the intercom and the AVPSU4 reducing noise pickup and a Ground Lift which prevents t...

Page 15: ...ty conscious The audio signals are transformer isolated at the intercom end and the BINREL02 has on board matching transformers which are switched in and out with the signal switching This provides a high degree of protection against unwanted voltage which may appear on the sites audio cabling and which could otherwise cause damage to the equipment The audio transformers also provide both a balanc...

Page 16: ...wn in the drawing Place an M3 plain washer on to the 4 studs which now protrude through the speech PCB and screw an M3 full nut on to each Connect the 6 way HE14 cable between the new speech PCB and the main intercom PCB below NOTE These plugs are polarised and will only fit snugly in the correct orientation PLEASE TAKE CARE When installation is complete adjust the control on the MAIN intercom PCB...

Page 17: ...DETAIL OF MECHANICAL FIXINGS FOR INTERCOM MESSAGE CARD DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 16 of 22 ...

Page 18: ...e cable types specified CONNECT INDICATOR LED 5 This LED indicator illuminates only when the AVPSU4 is connected to a powered up ADPRO FastScan series transmitter not FastVu or FastTrace CALL OUT INDICATOR LED 6 This LED indicator illuminates when the call input is open circuit This LED changes state in sympathy with the call input and may be used to identify when the push button is being pressed ...

Page 19: ...rcuited during installation or servicing the fuse may be reset by removing the overload and removing the 24 Volt DC power input to the AVPSU4 for about 15 seconds When the power is restored the fuse will have reset and the unit should function normally The audio connections to and from the AV102 should be wired according to the instructions and diagrams in this installation manual Connect the CALL...

Page 20: ...4 PARTS IDENTIFICATION DRAWING 7 6 5 4 3 2 1 1 DC power output to AV102SS intercom unit 2 Power on LED 3 Call Output Clean contact output changes when push button is being pressed 4 Terminals for wiring to and from AV102SS intercom unit 5 Connect LED Lights when system connected to a powered ADPRO Fast Scan transmitter 6 Call Out LED Changes state when call button pressed 7 15 Pin D connector For ...

Page 21: ...port for our products We have two fully equipped central station workstations running the latest version of ADPRO video central gold software We can therefore connect to ADPRO remote transmitters providing that they are on standard PSTN telephone lines modem standard ISDN lines terminal adapter or standard ADSL broadband connections We cannot connect via a clients VPN Virtual Private Network as th...

Page 22: ...t view above left SIDE VIEW 3mm Drain holes in bottom TOP VIEW FRONT VIEW C L 4 Mounting holes in rear All 6mm Dia On 90 X 197 mm centres 6 Faceplate mounting holes on front of backbox all threaded M4 C L This aperture shown shaded dimensions H 218mm W 110mm DOCUMENT NUMBER AV102SS OEM 01 REVISION 6 1 1st August 2006 Page 21 of 22 ...

Page 23: ...C Power Requirement 24 Volts DC 800mA Max Max Overall Dimensions H 300mm W 170mm D Top 150mm Bottom 100mm AVPSU4 Interface Power Supply Included in Kit Power Adapter Output 24 Volts DC Regulated 800mA max Included in Kit Supply Input 24 Volts DC Regulated 800mA max Supply Output 24 Volts DC Regulated 650mA max Call Input Opto Isolated Sources 24 Volts DC 12 mA Max Call Output SPST Clean Contact Si...

Reviews: