Z-Wave ZRW 113 Instructions, Series 200, Release 2.2
P/D 011008
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0766-01
2
INCLUDING ZRW113 TO THE NETWORK
STEP 1.
. Prepare the Controller to include a unit to the network by adding it to a group (method of adding a node
to the network). Refer to controller instructions.
STEP 2.
The ZRW113 must be in its permanently installed location.
Tap either the top or bottom of the
ZRW113 once.
STEP 3.
You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
NOTE:
If you have trouble adding the ZRW113 to a group it may be that the Home ID and Node ID were not
cleared from it after testing. You must first “RESET UNIT” with your controller to remove it from the network. If
using the ZTH100, select “MENU”, scroll to “SETUP” and scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network. If removed from a group, it functions as a repeater only. “RESET UNIT” removes it completely from
the network.
BASIC OPERATION
(Local Control)
The switch paddle on the ZRW113 allows the user to:
• Include or exclude the module from the Z-Wave system
• Turn on or off the attached load.
•
Control other Z-Wave enabled devices “associated” with the ZRW113.
Also, when a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap the switch on or
off once to satisfy those instructions.
• Tapping top of switch turns the load attached ON.
• Tapping bottom of switch turns the load attached OFF.
• Pressing and holding switch does not effect the load attached but will allow dimming and brightening of
Z-Wave dimmers if associated to the ZRW113 (see below for details).
LED indication
The LED on the ZRW113 will turn on when the load attached is ON. However, the LED can be user configured
to turn ON when the load attached is OFF to act as a night light, if so desired. See ADVANCED OPERATION.
The ZRW113 will flicker its LED when it is transmitting to any of its 2 groups. This can be changed if desired.
See ADVANCED OPERATION.
Auxiliary Switch
The ZRW113 supports the AS101 auxiliary switch to provide 3-way or 4-way operation.
Remote Control
The ZRW113 will respond to BASIC and BINARY commands that are part of the Z-Wave system. Refer to your
controller’s instructions as to whether your controller can transmit those commands.
ADVANCED OPERATION
All On/All Off
The ZRW113 supports the ALL ON/ ALL OFF commands.
The ZRW113 can be set to respond to ALL ON and ALL OFF commands 4 different ways.
Refer to your controller for information on how to set the ZRW113 to operate in the manner you desire. Some
controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The 4 different ways the ZRW113 can be setup to respond to ALL ON and ALL OFF commands are:
1. ZRW113 will not respond to ALL ON or the ALL OFF command.
2. ZRW113 will respond to ALL OFF command but will not respond to ALL ON command.
3. ZRW113 will respond to ALL ON command but will not respond to ALL OFF command.
4. ZRW113 will respond to ALL ON and the ALL OFF command.