Page 5
Residential Range
RS_10062016al
24"
24"
SIDE
BACK
TOP 8"
Note:
Close all open ended "S" hooks, chain links,
and turnbuckles or any open connection.
Figure 3: Outdoor Heater Installation
INSTALLATION
Outdoor Installation
For outdoor installations the heater must be installed not more than 8” from beneath awnings, and not less
than 24” from back and side as shown in Figure 4. If the heater cannot be protected from the elements by an
overhang, then a protective cover must be installed as shown in Figure 7, Figure 8 and Figure 9.
When the heater is installed with back and side dimensions greater than the minimum of 24” then the
top dimension may be increased. The new maximum Top dimension is 1/3 of the smallest side or back
clearance.
Example:
Given:
Side dimension = 36"
Back dimension = 48"
A ratio of 3:1 must be maintained
The side dimension gives us a maximum Top dimension of (36/3)" = 12"
The back dimension gives us a maximum Top dimension of (48/3)" = 16"
The new Top dimension is 12", the lesser of the two.