background image

Page 1 of 16 

 

 

MADE IN 

 
 
 
 

USA 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 

 

IMPORTANT SAFETY INFORMATION INSIDE 

 

 

Serious injury or death possible 

 

 

Read, understand, and follow all 
safety information and 
instructions in this manual before 
using or servicing this product. 

 

 

Retain these instructions for 
future reference. 

 
 

 

CSW-12-VD 

Portable Evaporative Cooler 

A Product of Advanced Radiant Systems, Inc. 

 

www.cool-space.com

  

[email protected]

  

 

Summary of Contents for Cool-Space CSW-12-VD

Page 1: ...ble Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CSW 12 VD Portable Evaporative Cooler A Product of Advanced Radiant Systems Inc www cool space com sales cool space com ...

Page 2: ......

Page 3: ...ure Page 9 Maintenance Pages 10 11 Troubleshooting Page 12 Replacement Parts Page 13 Warranty Page 14 ATTENTION The table to the right provides definitions of the signal words that can be found throughout this manual These signal words are used to express the severity of the hazard at hand The signal words are generally used in conjunction with safety symbols that correspond to the text for that p...

Page 4: ...al blower design Easy to operate and maintain plus an economical solution for low cost spot cooling Cooling media pad contains a paper treated CELdek material with a rigid protective edge coating Munters MI T edg to extend the life of the pad plus provide added weather and algae protection durability and formulated to withstand repeated cleaning without damage to the pad Ready to plug into any 120...

Page 5: ...urbulent mixing of air water for optimum cooling and enhanced self cleaning Cooling Media Size 18 x 18 and 4 thick Water Reservoir Capacity 10 gallons Switch Variable Cord 17 long 18 ga 3 conductor cord GFCI Protective Guard CSW 12VD Oscillating Power Supply 120 VAC 60 Hz 3 Amps Unit Dimensions 21 1 4 wide x 27 1 2 tall x 23 deep Unit Weight 51 lbs without water in reservior Water Supply Standard ...

Page 6: ...temperature is the lowest temperature that can be reached by evaporating water into the air Dew point temperature is the temperature to which a given sample of air must be cooled so that moisture will start condensing out of it When air is saturated the dry bulb wet bulb and dew point temperatures will all be equal The horizontal lines show the dew point temperature on the psychrometric chart Rela...

Page 7: ...lier type psychrometric chart for atmospheric pressure The dot shown is a state point and the following properties are known about the air water mixture at this state Take the air water mixture described by the state point above with a dry bulb temperature of 97 and 43 relative humidity for example As the air passes through the cooling media on the unit moisture is added to the air increasing the ...

Page 8: ...ect finish 2 Align wheel plate with embedded nuts on bottom of housing 3 Attach using 2 screws 4 Repeat steps 2 and 3 for each wheel ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before and during assembly of this product Pad Installation 1 Remove pad retainer bar 2 See page 12 Pads Washer 2 Screws 2 Pad retainer bar ...

Page 9: ...e regulator A pressure reducing valve is installed on the float inlet Do not fill the reservoir past the MAX water level line indicator CONNECTING THE WATER SUPPLY ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before and during assembly of this product This cooler comes equipped with a 120 volt power supply cord and should only be plugged into a 120 VA...

Page 10: ...ttempt should be made to locate the unit in such a manner that interruption of the air pattern is held to a minimum Multiple units may be required to cover large areas ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before servicing this product Annual start up At the beginning of each cooling season follow the same procedures as the initial start up wit...

Page 11: ...ses Odor from Initial Wetting of Pads 1 At first use of your new cooler or after installing new replacement pads make certain there is lots of fresh air available to the cooler 2 Add one capful of liquid laundry fabric softener to the water in the bottom reservoir of the cooler 3 The odor from initial wetting of pads should disappear in approx two weeks of operation 4 If odor does not disappear af...

Page 12: ...ations increase beyond a certain level the excess minerals precipitate out as a solid material This precipitation will appear as the familiar white residue left on the face of the media It is commonly referred to as alkali calcium depositions or salts The same process occurs in the desert when water collects in depressions and since only pure water evaporates the minerals are left behind These are...

Page 13: ...edia s ability to introduce water into the air stream If the pad surface becomes dirty or dusty clean with a soft brush and water Daily maintenance At start up It is best to run the pump several minutes before the fan is started to clean out any debris on the media At shut down When shutting down your evaporative cooler at the end of each workday the pump should be turned off approximately 15 minu...

Page 14: ...ystem consists of four primary elements Water Hose Float Assembly Pump and Water Distribution Channel Problem Check Solution Floor at side of the unit is wet Water inlet hose is loose at supply hose Tighten connections and or replace hose washers The unit overflows from reservoir Float valve hose is loose at bulkhead fitting or at float valve Water pressure is too high to allow float valve to shut...

Page 15: ...rranty contract or negligence and arising in connection with the sale use or repair of the Products Seller s maximum liability shall not in any case exceed the contract price for the Products claimed to be defective or unsuitable RETURNED GOODS Equipment may be accepted for return with in 90 days of shipment when authorized by us with our return labels Request necessary permission and special Retu...

Page 16: ......

Page 17: ..._____________ Address _______________________________________________________ Phone Number __________________ Fax Number ___________________ You must complete this form and return within fifteen 15 days of initial purchase to validate your cooler s warranty Please call COOLSPACE 800 557 5716 if you have questions Please fax or mail this completed form to Fax to 317 485 0118 Mail to COOL SPACE Warr...

Page 18: ......

Page 19: ...ion 315 North Madison Street Fortville IN 46040 Phone 317 577 0417 Fax 317 485 0118 1 800 557 5716 www cool space com sales cool space com REV 06 14jw PN CSW VD MANUAL If you have questions about the product you have purchased or would like to leave us feedback please contact us via our website www cool space com or by calling 1 800 557 5716 ...