3-8
Product Specifications
5705211-C
Advanced Energy
®
ENVIRONMENTAL SPECIFICATIONS
and
describe the environmental specifications.
Table 3-4.
Climatic specifications
Temperature
Relative Humidity
Air Pressure
Operating
Class 3K3
5
°
C to +40
°
C
+41
°
F to +104
°
F
Class 3K2
10% to 85%
Note
1
+2 g/m
3
to +25 g/m
3
Class 3K3
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Storage
Class 1K4
-25
°
C to +55
°
C
-13
°
F to +131
°
F
Class 1K3
5% to 95%
+1 g/m
3
to +29 g/m
3
Class 1K4
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Transportation
Class 2K3
-25
°
C to +70
°
C
-13
°
F to +158
°
F
Class 2K3
95%
Note
2
+60 g/m
3
Note
Class 2K3
70 kPa to 106 kPa
700 mbar to 1060 mbar
(approximately 3265 m
above sea level)
Note
1
Noncondensing
Note
2
Maximum relative humidity when the unit temperature slowly increases, or when the unit
temperature directly increases from -25°C to +30°C
Note
3
Maximum absolute humidity when the unit temperature directly decreases from +70°C to
+15°C
Table 3-5.
Environmental specifications
Description
Specification
Overvoltage
Category II
Pollution degree
2
Coolant requirements
Temperature
+15
°
C to +30
°
C (+59
°
F to +86
°
F) inlet temperature
Flow rate
11.4 lpm (3 gpm) minimum
Summary of Contents for HFV 8000
Page 1: ...HFV 8000 Generator 2 MHz 208 V Input with DeviceNet March 2004 5705211 C User Manual...
Page 2: ......
Page 3: ...User Manual HFV 8000 Generator 2 MHz 208 V Input with DeviceNet 5705211 C...
Page 6: ...iv 5705211 C Advanced Energy...
Page 14: ...xii 5705211 C Advanced Energy...
Page 22: ...1 8 Safety and Product Compliance Guidelines 5705211 C Advanced Energy...
Page 26: ...2 4 Product Overview and Theory 5705211 C Advanced Energy...
Page 36: ...3 10 Product Specifications 5705211 C Advanced Energy...
Page 94: ...4 58 Communication Interfaces 5705211 C Advanced Energy...
Page 114: ...5 20 Installation Setup and Operation 5705211 C Advanced Energy...
Page 128: ...6 14 Troubleshooting and Global Customer Support 5705211 C Advanced Energy...
Page 132: ...iv 5705211 C Advanced Energy...
Page 134: ...5705211 C ii HFV 8000 Generator...
Page 140: ...5705211 C viii HFV 8000 Generator...
Page 141: ...ix 5705211 C Advanced Energy...
Page 142: ...Index x 5705211 C Advanced Energy...