6-6
Troubleshooting and Global Customer Support
5705211-C
Advanced Energy
®
Bottom line—Center/Auto Tune
2. Press and hold the
Display Mode
button for at least five seconds until the
Load
Regulation
indicator flashes.
To return to the automatic tuning mode:
1. Press the
Display Mode
button on the front panel repeatedly until the display
reads:
Top line—Press and Hold
Bottom line—Center/Auto Tune
2. Press and hold the
Display Mode
button for at least five seconds until the
Load
Regulation
indicator does not flash.
RF On Indicator Off
When the front panel
RF On
indicator illuminates, the output is enabled and the set
point (or requested power level) is above the minimum required setting. In order for
the RF On indicator to be on, the following conditions must be met:
1. The front panel
Fault
indicator must be off.
If this indicator is on, see
“Fault Indicator On” on page 6-3
.
2. The front panel
Interlock OK
indicator must be on.
“Interlock OK Indicator Off” on page 6-5
.
3. In order for the HFV generator to deliver power, the unit must receive an RF on
command,
and
the set point (or requested output power level) must be above a
). When these two conditions are
met, the RF On indicator should illuminate, and the generator will deliver power.
Note:
How to send the RF on command depends how the unit is controlled:
•
For
Generator User
port control, verify:
There is an external contact closure between pins
4
and
9
to enable the RF
output power. See
.
•
For
DeviceNet
control, verify:
An RF on command is given by having Bit 0 of Byte 4 of the poll command
message set to 1. See
“Poll Command and Poll Response Messages” on
for more details.
The output power set point minimum is a threshold that allows the generator to
deliver power (see
“Meeting Minimum Power Threshold” on page 5-11
set point circuitry uses hysteresis, so the generator has two thresholds. If an RF
on command is given, the set point level must be above the output on threshold
Summary of Contents for HFV 8000
Page 1: ...HFV 8000 Generator 2 MHz 208 V Input with DeviceNet March 2004 5705211 C User Manual...
Page 2: ......
Page 3: ...User Manual HFV 8000 Generator 2 MHz 208 V Input with DeviceNet 5705211 C...
Page 6: ...iv 5705211 C Advanced Energy...
Page 14: ...xii 5705211 C Advanced Energy...
Page 22: ...1 8 Safety and Product Compliance Guidelines 5705211 C Advanced Energy...
Page 26: ...2 4 Product Overview and Theory 5705211 C Advanced Energy...
Page 36: ...3 10 Product Specifications 5705211 C Advanced Energy...
Page 94: ...4 58 Communication Interfaces 5705211 C Advanced Energy...
Page 114: ...5 20 Installation Setup and Operation 5705211 C Advanced Energy...
Page 128: ...6 14 Troubleshooting and Global Customer Support 5705211 C Advanced Energy...
Page 132: ...iv 5705211 C Advanced Energy...
Page 134: ...5705211 C ii HFV 8000 Generator...
Page 140: ...5705211 C viii HFV 8000 Generator...