Troubleshooting and Global Customer Support
6-5
HFV 8000 Generator
4
Cycle the power on the HFV generator. With the cable disconnected, the HFV
generator will default to
Generator User
port control.
Interlock OK Indicator Off
The front panel
Interlock OK
indicator illuminates when the interlock is satisfied. If
this indicator is not lit, the output will be disabled. Three settings on the HFV
generator will satisfy the interlock circuit.
1. The front panel
Standby/Stop
rocker switch must be in the
Standby
(up)
position.
Standby is the closed position for this switch.
2. The RF output cover must be firmly attached.
A microswitch on the rear panel senses the presence of the output cover.
3. There must be an external closure between pins
11
and
12
on the rear panel
Generator User
port. This closure must have a series resistance of 15
Ω
or less
and should have no other external loading. (See
for an
electrical diagram.)
WHAT IS THE INTERLOCK?
The HFV generator uses an interlock circuit to shut off the output in emergency
situations. The interlock circuit is basically several switches wired in series. The
interlock loop of the HFV generator must be closed (or satisfied) before the output
power can be enabled.
Note:
When this loop is interrupted, the unit disables the output by opening the main
contactor inside the supply. Once the interlock is reestablished, the main
contactor will close, but the output will not come on until the RF power is
cycled. (See
for an electrical diagram.)
Load Regulation Indicator Flashing
During normal operation, the Load Regulation indicator will either be on (load power
regulation) or off (forward power regulation).
When this indicator is flashing, the unit is in center frequency mode.
Center
Frequency
mode is used only to optimize settings on some systems during initial
setup.
To select Center Frequency mode:
1. Press the
Display Mode
button on the front panel repeatedly until the display
reads:
Top line—Press and Hold
Summary of Contents for HFV 8000
Page 1: ...HFV 8000 Generator 2 MHz 208 V Input with DeviceNet March 2004 5705211 C User Manual...
Page 2: ......
Page 3: ...User Manual HFV 8000 Generator 2 MHz 208 V Input with DeviceNet 5705211 C...
Page 6: ...iv 5705211 C Advanced Energy...
Page 14: ...xii 5705211 C Advanced Energy...
Page 22: ...1 8 Safety and Product Compliance Guidelines 5705211 C Advanced Energy...
Page 26: ...2 4 Product Overview and Theory 5705211 C Advanced Energy...
Page 36: ...3 10 Product Specifications 5705211 C Advanced Energy...
Page 94: ...4 58 Communication Interfaces 5705211 C Advanced Energy...
Page 114: ...5 20 Installation Setup and Operation 5705211 C Advanced Energy...
Page 128: ...6 14 Troubleshooting and Global Customer Support 5705211 C Advanced Energy...
Page 132: ...iv 5705211 C Advanced Energy...
Page 134: ...5705211 C ii HFV 8000 Generator...
Page 140: ...5705211 C viii HFV 8000 Generator...
Page 141: ...ix 5705211 C Advanced Energy...
Page 142: ...Index x 5705211 C Advanced Energy...