5705211-C
Communication Interfaces
4-33
HFV 8000 Generator
220
report
customer
service
statistics
Reads statistics on events in the unit. The
command from the Host should contain a
one-byte number indicating which statistic
value is wanted. The controller returns 4
bytes (4-9 represent a 32-bit number count of
the event):
• 0 = AC On total time
• 1 = RF On total time
• 2 = Total kilowatt-hours delivered
• 3 = Joules
• 4 = The number of times the unit has
been powered on
• 5 = The number of times RF output has
been enabled
• 6 = The number of
DeviceNet
communication faults that has occurred
• 7 = The number of times RF enable has
been set without the interlock set
• 8 = The number of line faults that have
occurred
• 9 = The number of overtemperature
faults that have occurred
• 10 = The number of host port heartbeat
time-outs
1
4
221
report last
ten faults
Returns fault codes for the last ten faults. The
controller returns 10 bytes. Each byte
contains a fault code. The low order byte is
the most recent fault. The fault codes are:
• 0 = No fault
• 1 = Overtemperature fault
• 2 = Line fault
• 3 = RF enable without interlock fault
• 4 =
DeviceNet
communications fault
• 5 to 254 = Undefined
0
10
Table 4-7.
Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for HFV 8000
Page 1: ...HFV 8000 Generator 2 MHz 208 V Input with DeviceNet March 2004 5705211 C User Manual...
Page 2: ......
Page 3: ...User Manual HFV 8000 Generator 2 MHz 208 V Input with DeviceNet 5705211 C...
Page 6: ...iv 5705211 C Advanced Energy...
Page 14: ...xii 5705211 C Advanced Energy...
Page 22: ...1 8 Safety and Product Compliance Guidelines 5705211 C Advanced Energy...
Page 26: ...2 4 Product Overview and Theory 5705211 C Advanced Energy...
Page 36: ...3 10 Product Specifications 5705211 C Advanced Energy...
Page 94: ...4 58 Communication Interfaces 5705211 C Advanced Energy...
Page 114: ...5 20 Installation Setup and Operation 5705211 C Advanced Energy...
Page 128: ...6 14 Troubleshooting and Global Customer Support 5705211 C Advanced Energy...
Page 132: ...iv 5705211 C Advanced Energy...
Page 134: ...5705211 C ii HFV 8000 Generator...
Page 140: ...5705211 C viii HFV 8000 Generator...
Page 141: ...ix 5705211 C Advanced Energy...
Page 142: ...Index x 5705211 C Advanced Energy...