DANGER:
Assurez-vous que la polarité et le voltage des câbles positifs et négatifs des
piles PV sont corrects avant de brancher les câbles des piles PV aux bornes
CC.
The connection box provides overcurrent and overvoltage protection for the DC side
of the inverter. The DC input fuse holders are used to disconnect the PV array
modules for servicing.
600 SERIES
The DC terminals are connected to the PV array modules using the two banks of DC
fuse holders, DC1 and DC2. Each DC bank has ten fuse holders to connect to the
positive and negative PV array conductors.
shows the terminal block locations used to connect the DC conductors
from the PV modules. The incoming voltage and current from the PV arrays must be
balanced between DC1 and DC2, and must be kept separate. The installation must
have identically configured strings, including the same type and number of PV
modules, balanced equally between DC1 and DC2. This is necessary to stay within
safe operating limits of the inverter.
DC1 inputs
DC2 inputs
Figure 4‑8. 600 series DC terminal block locations
1000 SERIES
The 1000 series includes six string input pairs with no balancing requirements.
Advanced Energy
4‑18
Installing
570-1003552-05A
Summary of Contents for AE 3TL 1000 Series
Page 2: ......
Page 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Page 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Page 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Page 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Page 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Page 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Page 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Page 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Page 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...