Advanced Card Systems AET63 BioTRUSTKey Reference Manual Download Page 29

AET63 Reference Manual                                                                                    

version 1.8 September 2006 

 Advanced Card Systems Ltd. 

Page 29 of 29

 

 

Appendix C:  Technical Specifications  

Device 

AET63 BioTRUSTKey  

Power supply

 

Power supply ........................................ USB powered 
Supply voltage ...................................... Regulated 5V DC 

Universal Serial Bus Interface

 

Type ..................................................... USB v1.1, four lines: +5V, GND, D+ and D- 
Power source........................................ From USB 
Speed ................................................... 1.5 Mbps (Low Speed) 

Smart Card Interface

 

Standard ............................................... ISO 7816 1/2/3, T=0 and T=1 
Supply current....................................... max. 50mA 
Smart card read / write speed ............... 9600 – 96000 bps 
Short circuit protection  ......................... +5V / GND on all pins 

The presence of the smart card power supply voltage is indicated through a green LED on the reader 

CLK frequency ...................................... 4 MHz 
Card connector ..................................... Landing contacts (8 contacts)  
Card insertion cycles............................. min. 100,000 

Fingerprint Scanner Interface

 

Power consumption  ............................. Active mode : 20mA @ 5V + 105mA @ 3.3V  
 

Sleep mode :< 1mA @ 5V + 70µA @ 3.3V 

Active sensor size................................. 12.8 x 18 mm 
Array size ............................................. 256 x 360 pixels 
Image resolution  .................................. 508 DPI 
ESD tolerant  ........................................ +/- 15kV air discharge 

Case

 

Color..................................................... Silver-gray 

Operating Conditions

 

Temperature ......................................... 0 - 50

°

 C 

Humidity................................................ 5% - 93% 

Standard/Certifications

 

CE, FCC 

OS

 

Windows 98, ME, NT4, 2K, XP and Linux 

OEM

 

OEM-Logo possible, customer-specific colors  

 

Note

:  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may 

not  cause  harmful  interference,  and  (2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation.  
 

 

Warning

:  Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment. 

 

NOTE:

  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio communications.  

 
However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures: 
 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Summary of Contents for AET63 BioTRUSTKey

Page 1: ...n 1 8 09 2006 Unit 1008 10th Floor Hongkong International Trade and Exhibition Centre 1 Trademart Drive Kowloon Bay Hong Kong Tel 852 2796 7873 Fax 852 2796 1286 Email info acs com hk Website www acs...

Page 2: ...transmission error with normal response Length 255 bytes 10 7 2 2 No transmission error with extended response 12 7 2 3 Transmission error 12 7 3 Card Status Message 13 7 4 Transmission Protocol 13 8...

Page 3: ...AET63 Reference Manual version 1 8 September 2006 Advanced Card Systems Ltd Page 3 of 29 Appendix A Supported Card Types 27 Appendix B Response Status Codes 28 Appendix C Technical Specifications 29...

Page 4: ...art card operation which are in many cases not relevant for the implementation of a smart card system The AET63 BioTRUSTKey is connected to the computer through USB interface The reader accepts comman...

Page 5: ...orms the Protocol and Parameters Selection PPS procedure as specified in ISO7816 3 1997 When the card ATR indicates the specific operation mode TA2 present bit b5 of TA2 must be 0 and that particular...

Page 6: ...owever this selection is only accepted and carried out by the reader through the PPS when the card inserted in the reader supports both protocol types Whenever an MCU based card supports only one prot...

Page 7: ...the device First Green LED Indicates power supply to the device i e the device is receiving power from the computer As long as the device is connected to the PC this LED light is on Second Green LED...

Page 8: ...s working in low speed mode i e 1 5 Mbps USB Interface Wiring Pin Signal Function 1 VBUS 5V power supply for the reader 2 D Differential signal transmits data between AET63 and PC 3 D Differential sig...

Page 9: ...255 N 4 Header Instruction Data length N Data Checksum Header 01H to indicate the start of a standard command 02H to indicate the start of an encrypted command support from firmware 0 67 onwards only...

Page 10: ...a Data contents of the command For a READ command for example the data bytes would specify the start address and the number of bytes to be read For a WRITE command the data bytes would specify the sta...

Page 11: ...alues of the status bytes SW1 and SW2 and the corresponding meaning is given in Appendix B Data Length Number of subsequent data bytes 0 N 255 Data Data contents of the command For a READ_DATA command...

Page 12: ...ossible values of the status bytes SW1 and SW2 and the corresponding meaning is given in Appendix B Data Length Number of subsequent data bytes and is encoded in 3 bytes The first byte is FFH The seco...

Page 13: ...by the reader after a reset The Card Status Messages have the following structure and contents Card Status Message for Card Insertion byte 1 2 3 4 5 Header SW1 SW2 Data length Checksum 01 H FF H 01 H...

Page 14: ...instruction code A2H and one data byte with the value 3DH The command has the following structure byte 1 2 3 4 5 Header Instruction Data length Data Checksum 01H A2H 01H 3DH 9FH This command is transm...

Page 15: ...whether a card is inserted and powered up Command format Instruction Code Data length 01 H 00 H Response data format INTERNAL MAX_C MAX_R C_TYPE C_SEL C_STAT INTERNAL 10 bytes data for internal use o...

Page 16: ...ESET This section describes the RESET command only for the case when no card type is selected or when the card type 00H is selected For all other cases please refer to the specific section described f...

Page 17: ...nstruction Code Data length Data Option 07 H 01 H Option Bit 0 LSB bit Select for PPS mode Specifies reader card communication speed 0 baud rate to from the card is from 9600 bps to 96000 bps default...

Page 18: ...the EEPROM memory 8 2 2 EEPROM_WRITE_DATA This command is used to write the specified data bytes to the specified address of the EEPROM Note The EEPROM used in AET63 is 24C512 with a page size of 64 b...

Page 19: ...BYTE 2 BYTE 3 BYTE N BYTE x Data bytes returned by the TFM please refer to TFM API Documentation 8 3 2 TFM_RESET This command resets the TFM and then waits for the ATR returned from the TFM Command fo...

Page 20: ...ed information Response data format No response data Address 0x7F00 Address 0x0900 Address 0x0800 Address 0x0700 Address 0x0600 Address 0x0500 Address 0x0400 Address 0x0300 Address 0x0200 Address 0x01...

Page 21: ...4 TFM_OPEN_SECURE_SESSION This command sends 24 bytes of random number to AET63 The random number is used to general the session key Command format Instruction Code Data length Data LEN 9F H 18 H Dat...

Page 22: ...ATR is only returned in the AET63 response if the communication protocol of the card is compatible with the reader i e if the card can be processed by the AET63 Otherwise the AET63 returns an error st...

Page 23: ...than 0 in an EXCHANGE_APDU command when a T 0 card is in the reader If both parameters have a value greater than 0 the AET63 does not execute the command and returns an error status Response data for...

Page 24: ...sponse Command format Instruction Code Data length Data SM 88 H 01 H SM Must be 0 reserve for future use Response data format ATR ATR Answer To Reset as transmitted by the card according to ISO7816 3...

Page 25: ...r byte 1 P2 APDU parameter byte 2 Lc APDU command data length BYTE x APDU command data Le Expected APDU response data length Le 0 menas no data is expected from the card NOTE With the T 0 communicatio...

Page 26: ...Protocol Data Unit command response pair between the SAM card inserted in the AET63 and the host computer using T1 protocol Command format Instruction Code Data length Data LEN T1 BLOCK FRAME B1 H LEN...

Page 27: ...type to be used and how the bits in the response to the GET_ACR_STAT command correspond with the respective card types Cyber mouse card type code Card Type 00H Auto select T 0 or T 1 communication pr...

Page 28: ...the SELECT_CARD_TYPE command 60 01 No card type selected 60 02 No card in reader 60 03 Wrong card type specified 60 04 Card not powered up This status code is also returned in a response if the card w...

Page 29: ...ollowing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Chang...

Reviews: