Advanced Amplifiers AA-10K250M-150 Instruction Manual Download Page 4

4  | 

P a g e

 - Ver. 1.0

 

SPECIFICATIONS

 

ELECTRICAL SPECIFICATIONS

: 50Ω, 25°C

 

Parameter

 

Specification

 

Notes

 

Operating Frequency Range

 

10 KHz - 250 MHz

 

Power Output @ Psat

 

150 Watt Min

 

CW or Pulse

 

Power Output @ P1dB

 

70 Watt Typ

 

Power Gain

 

52 dB Min

 

0dBm or less for Rated Power

 

Power Gain Flatness

 

4.0 dB p-p Max

 

Constant input power

 

Gain Adjustment Range

 

>20 dB Typ

Local or remote capable

 

Input Return Loss

 

-10 dB Max

2-Tone Intermodulation (IMD)

<-30 dBc Typ

 

42dBm/Tone, Δ = 1MHz

 

Harmonics

 

<-20 dBc Typ

 

At rated output

 

Spurious

 

-60 dBc Max

Non-harmonic

 

Operating Voltage

 

100 - 240 VAC

 

47-63 Hz

Power Consumption

 

600 Watt Max

 

At rated output

 

Input Power Protection

 

+10 dBm Max

1

Load VSWR Protection

 

4 : 1: Max

2

 

Foldback @ preset limit

 

Sample Port (optional)

 

-50 dB

N-Female

1 Units with optional digital monitor and control, for basic units <10 Sec without damage

 

2 Units with optional digital monitor and control, for basic units <1 minute at rated Pout

 

ENVIRONMENTAL CHARACTERISTICS

 

Parameter

 

Specification

 

Notes

 

Operating Ambient Temperature

 

0 to +50 °C

 

Storage Temperature

 

-40 to +85 °C

Relative Humidity

 

up to 95 %

 

Non-condensing

 

Altitude

 

3000 meters

 

Shock & Vibration

 

Normal transport

3

 

MECHANICAL SPECIFICATIONS

 

Parameter

 

Specification

 

Notes

 

Dimensions W x H x D

 

430 x 133 x 560 mm

 

3U - excluding handles

 

Weight

 

18 Kg. Max

 

RF Conn. In / Out / Sample

 

N-Female

Front or rear panel

 

Interface Connector

 

9-Pin D-Sub

Rear panel

 

AC Power

 

IEC 60320-C14

 

Or equivalent

 

Safety Interlock Connector

 

D-Sub (Optional BNC female)

Open=STBY/Short=RFON

 

Cooling

 

Built in Fan Cooling

 

Variable speed

 

STANDARD:

 Digital Monitor & Control (DMC

3

)

 

FWD, REV, VSWR, GAIN, ALC, V & I, TEMP,

 

Safety Interlock (INT)

 

Ethernet RJ-45 TCP/IP, RS422/485, USB

 

GPIB Interface

 

Open=STBY/Short=RFON

 

IEEE rear panel

 

BNC-F rear panel

 

3 Controller/coupler can reduce output power by approx. 1.0dB.

 

Summary of Contents for AA-10K250M-150

Page 1: ...1 P a g e Ver 1 0 Instruction Manual Including Quick Start Guide Advanced Amplifiers Solid State RF Amplifier System AA 10K250M 150 10 KHz 250 MHz 150 Watt 52 dB Min...

Page 2: ...ECHANICAL SPECIFICATIONS 4 OPERATING INSTRUCTIONS GENERAL INFORMATION 5 INTRODUCTION 5 INCOMING INSPECTION 5 RF AC CABLE CONNECTION 5 RF TURN ON PROCEDURE 5 RF TURN OFF PROCEDURE 5 DECLARATION OF CE C...

Page 3: ...ing the output load or other components The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord REPAIR MAINTENANCE All repair or main...

Page 4: ...asic units 10 Sec without damage 2 Units with optional digital monitor and control for basic units 1 minute at rated Pout ENVIRONMENTAL CHARACTERISTICS Parameter Specification Notes Operating Ambient...

Page 5: ...nterface and commands list is in the second part of the manual RF AC CABLE CONNECTION RF Input and Output connectors are outlined in the specifications table Use the standard AC cable that was supplie...

Page 6: ...replacement of defective goods F O B factory of which Seller is modified in writing by Buyer within three 3 years following delivery thereof to Buyer and in no event will Seller be liable for incident...

Page 7: ...VIEW No Title Function 1 RF INPUT N Female RF INPUT Connector 2 RF Sample N Female RF SAMPLE Connector 3 FAULT LED System Fault LED Turn ON an LED when System Fault Over Input Over Temp Over Current...

Page 8: ...DEBUG System Controller Debugging Female Connector Customer should not use this port without permission from the factory 5 USB USB Communication Connector Type A Female 6 ETHERNET Ethernet Communicati...

Page 9: ...9 P a g e Ver 1 0 SYSTEM OUTLINE VIEW...

Reviews: