background image

WARRANTY

COMPONENT LIST

Component

Reference

3 kw immersion heater (high temp)

AA 0005

Control thermostat for above (high temp)

AA 0007

High limit thermostat for above

AA 0006

Blending valve

AA 0002

Expansion vessel 2 litre

AA 0001

Float switch and motorised valve kit  

AA 0300

Only use authorised replacement components.

TECHNICAL DATA

Warranty is for ten years on the tank against failure due to manufacturing fault,
and two years on components supplied and fitted to the heating manifold and
thermal store.

DISPOSAL

At the end of the life of the product please dispose of in line with any
regulations ruling at the time

Conditions apply, the unit must be serviced annually and a record of service 
must be maintained. It must be in a frost free environment and must be used
for public mains potable water only. It must be installed and used correctly
in  accordance  with  manufacturer’s  requirements  and  current  best  practice.
Corrosion and scale are not covered. Chlorine/chloride levels must be below
200ppm. The store must be inhibited to correct dose.

Your 

Scale is not covered

statutory rights are not affected by the above.

CAPACITY

HEAT LOSS : 56 WATTS

CLASS : D

OFF PEAK USE

WEIGHT

IMM

FULL Kg

HEATERS

HGT X

DIA

160 ltrs

230

2 x 3Kw

585 x 1450

HOT WATER

COIL M

2

1.5m

HW COIL

OUTPUT

35 Kw

947219 ADVANCE APPLIANCES 8pp A5_Layout 1  10/11/2015  14:41  Page 6

Summary of Contents for ETS 160

Page 1: ...AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ETS 160 ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE ISSUE 4 0214 ISSUE 6 1115 947219 ADVANCE APPLIANCES 8pp A5_La...

Page 2: ...Section Vent and Water Level Indicator Temperature Gauge BlendingValve ServiceValve 2 L Expansion Vessel Hot Out 3kw Immersion Heater 3kw Immersion Heater Hot Water Coil Cold In Drain 947219 ADVANCE A...

Page 3: ...ng without a pump and fast bath filling The unit can be fitted and left isolated from the filling point if it is not possible to fit an overflow The blending valve can be orientated to right or left h...

Page 4: ...nnection with a 22mm push fit or compression end stop to prevent evaporation For additional protection a float switch can be used connected to a motorised two port valve on the cold inlet This is avai...

Page 5: ...ree life however they should be serviced periodically Advance recommends a service at least every two years It is important that the store temperature is maintained It is critical that the water level...

Page 6: ...ine with any regulations ruling at the time Conditions apply the unit must be serviced annually and a record of service must be maintained It must be in a frost free environment and must be used for p...

Page 7: ...947219 ADVANCE APPLIANCES 8pp A5_Layout 1 10 11 2015 14 41 Page 7...

Page 8: ...ly products that meet or exceed appropriate standards and building and water regulations To provide pre and post sales technical support To provide clear and concise warranty details to customers UNIT...