background image

FORM NO. 56041988 - Adgressor

, Adgressor

 EcoFlex

 - 

A-11

ENGLISH / A-11

OPERATING THE MACHINE

 WARNING!

Be sure you understand the operator controls and their functions.
While on ramps or inclines, avoid sudden stops when loaded.  Avoid abrupt sharp turns.  Use low speed down hills.  Clean only while 
ascending (driving up) the ramp.

To Scrub...

Follow the instructions in preparing the machine for use section of this manual.

While seated on the machine, adjust the seat and steering wheel to a comfortable operating position using the adjustment controls 

(25)

 and 

(5)

.

Turn the Master Key Switch 

(J)

 ON (I).  This will display the control panel indicator lights, reference the Battery Condition Indicator 

(K)

 and Hour Meter 

(G)

.

Release the Parking Brake 

(6)

.  To transport the machine to the work area, apply even pressure with your foot on the front of the Drive Pedal 

(8)

 to go forward or the rear 

of the pedal for reverse.  Vary the pressure on the foot pedal to obtain the desired speed.

Adjust the Solution Flow Control Valve Lever 

(7)

 to about 1/4 to 1/3 open position 

(Non EcoFlex models).

 

Press the Flow Rate Switch 

(T)

 to select a solution 

fl

 ow rate 

(EcoFlex models)

.

 The 

fl

 ow rate can be changed to allow variable solution 

fl

 ow for different types of 

fl

 oors to be scrubbed.  Example: A rough or absorbent 

fl

 oor surface such as un

fi

 nished 

concrete, will require more solution than a smooth 

fi

 nished 

fl

 oor.

 

NOTE (Non EcoFlex Models):

  For a consistent reduced 

fl

 ow of solution; open the Solution Flow Control Valve Lever 

(7)

 all the way and then turn ON the Smart 

Solutions™ Valve 

(26)

. When the lever is in the “OFF” position; the machine operates conventionally; solution 

fl

 ow is determined by the Solution Flow Control Lever 

(7)

.  

When the lever is in the “ON” position; solution 

fl

 ow is controlled automatically.  The Solution Flow Control Lever 

(7)

 should not be shut off, but is otherwise inactive.  Make 

sure that the lever for Valve 

(26)

 is all the way ON or all the way OFF, never in between. If more solution is needed, turn OFF the Smart Solutions™ Valve 

(26)

 and adjust 

the solution 

fl

 ow with the Solution Flow Control Valve Lever 

(7).

NOTE:

  The solution, vacuum and detergent (EcoFlex models) systems are automatically activated when the Scrub Pressure Decrease Switch 

(D)

 or the Scrub Pressure 

Increase Switch 

(F)

 is pressed.  No further action is required.  Any individual system can be turned OFF or back ON by simply pressing its switch at any time during 

scrubbing.

Press and hold the Solution Switch 

(R)

 for 5 seconds to pre-wet the 

fl

 oor.  

NOTE:

  This must be done prior to pressing the Scrub ON Switch 

(F)

.

When the Scrub Pressure Decrease Switch 

(D)

 or the Scrub Pressure Increase Switch 

(F)

 is selected, the brushes and squeegee are automatically lowered to the 

fl

 oor.  

The machine’s scrub brush rotation, solution system 

fl

 ow, vacuum and detergent (EcoFlex models) starts when the Drive Pedal 

(8)

 is activated.  Note:  When operating the 

machine in reverse, only the brushes will rotate, the solution and detergent (EcoFlex models) is automatically shut off to conserve usage.

Begin scrubbing by driving the machine forward in a straight line at a normal walking speed and overlap each path by 2-3 inches (50-75 mm). Adjust when necessary the 
machine speed and solution 

fl

 ow according to the condition of the 

fl

 oor.

 CAUTION!

To avoid damaging the 

fl

 oor, keep the machine moving while the brushes are turning.

When scrubbing, check behind the machine occasionally to see that all of the waste water is being picked up.  If there is water trailing the machine, you may be dispensing 
too much solution, the recovery tank may be full, or the squeegee tool may require adjustment.

EcoFlex models only:

 The machine defaults to the EcoFlex cleaning mode (EcoFlex Switch Indicator 

(X)

 is lit GREEN) conserving solution and detergent.  Press the 

EcoFlex Switch 

(Y)

 to override the EcoFlex cleaning mode and temporarily increase solution 

fl

 ow and the detergent ratio.  This will cause the indicator 

(X)

 to 

fl

 ash green 

for one minute, solution 

fl

 ow rate will increase to the next level and the detergent ratio will increase to the pre-programmed ratio. The pre-programmed ratio that is used 

during EcoFlex override can be adjusted. With the detergent system OFF, press and hold the Detergent ON/OFF Switch 

(S)

 for 2 seconds. The detergent indicator 

(U)

 will 

fl

 ash and each press of the switch will cycle through the available ratios (1:32(#9), 1:50(#8), 1:64(#7), 1:100(#6), 1:128(#5), 1:200(#4), 1:256(#3), 1:300(#2), 1:400(#1)). 

Once the desired ratio # is displayed on the display 

(W)

, stop and it will lock in after 5 seconds.

 

NOTE:

  Pressing and holding the EcoFlex Switch 

(Y)

 for 2 seconds disables the EcoFlex system.  The only way to re-enable is to push the EcoFlex Switch 

(Y)

 again.  

Cycling the Key Switch 

(J)

 does not re-enable the system.  The EcoFlex system will only function if the Scrub System 

(D or F)

 has been enabled.

10  For extremely dirty 

fl

 oors, a one-pass scrubbing operation may not be satisfactory and a “double-scrub” operation may be required.  This operation is the same as a 

one-pass scrubbing except on the 

fi

 rst pass the squeegee is in the up position (press the Vacuum Switch 

(O)

 to raise the squeegee).  This allows the cleaning solution to 

remain on the 

fl

 oor to work longer.  The 

fi

 nal pass is made over the same area, with the squeegee lowered to pick up the accumulated solution.

11 

The recovery tank has an automatic 

fl

 oat shut-off to prevent solution from entering the vacuum system when the recovery tank is full.  When the 

fl

 oat shut-off is activated, 

the control system will shut down the scrub, vacuum, solution and detergent (EcoFlex models) systems. The Scrub Pressure / Hourmeter Display 

(G)

 will display “FULL”.  

To clear the display, press the Scrub OFF Switch 

(B)

, Scrub Pressure Decrease Switch 

(D)

, Scrub Pressure Increase Switch 

(F)

 or the Vacuum Switch 

(O)

.  When the 

fl

 oat 

closes, the recovery tank must be emptied.  The machine will not pick up water with the 

fl

 oat closed.  

NOTE:

  If the control repeatedly gives a full indication when the tank 

is not full, the automatic shut-off feature can be disabled, have a quali

fi

 ed service technician refer to the service manual to perform this function.

12  When the operator wants to stop scrubbing or the recovery tank is full, press the Scrub OFF Switch 

(B)

 once.  This will automatically stop the scrub brushes and solution 

fl

 ow and the scrub deck will raise UP.  

NOTE:

  the vacuum/squeegee system will not be turned off when the switch is only pressed once, this is to allow any remaining 

water to be picked up without turning the vacuum back on.  Press the switch a second time and the squeegee will raise and the vacuum will stop after a 10 second delay.

13  Drive the machine to a designated waste water “DISPOSAL SITE” and empty the recovery tank.   To empty, pull the Drain Hose 

(21)

 from its rear storage area, then 

remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled 

fl

 ow of waste water).  Re

fi

 ll the solution tank and continue 

scrubbing.

Summary of Contents for Adgressor EcoFlex Series

Page 1: ...ñol MODELS 56390900 2820D 56390904 3220D 56390908 3520D 56390912 3820D 56390902 2820C 56390906 3220C 56390910 3520C 56390914 3820C 56381000 X2820D 56381002 X3220D 56381004 X3520D 56381006 X3820D 56381001 X2820C 56381003 X3220C 56381005 X3520C 56381007 X3820C Adgressor Adgressor EcoFlex ...

Page 2: ...red should be performed by your Authorized Advance Service Center who employs factory trained service personnel and maintains an inventory of Advance original replacement parts and accessories Call the ADVANCE DEALER named below for repair parts or service Please specify the Model and Serial Number when discussing your machine Dealer affix service sticker here NAME PLATE The Model Number and Seria...

Page 3: ... machine on or near these agents or operate in areas where flammable liquids exist Do not clean this machine with a pressure washer Only use the brushes provided with the appliance or those specified in the instruction manual The use of other brushes may impair safety CAUTION This machine is not approved for use on public paths or roads This machine is not suitable for picking up hazardous dust Do...

Page 4: ...é au préalable des blocs de sécurité ou des étais destinés à soutenir la machine Ne déversez pas d agents nettoyants inflammables ne faites pas fonctionner la machine à proximité de ces agents ou d autres liquides inflammables Ne nettoyez pas cette machine avec un nettoyeur à pression Utilisez uniquement les brosses fournies avec l appareil ou celles spécifiées dans le manuel d instructions L util...

Page 5: ...Solution Tank Drain Hose 5 Steering Wheel Tilt Adjust Knob 6 Brake Pedal Parking Brake 7 Solution Flow Control Lever 8 Drive Pedal Directional Speed 9 Hopper cylindrical models only 10 Drive and Steer Wheel 11 Wheel Drive Circuit Breaker 12 Control Circuit Circuit Breaker 13 Emergency Stop Switch Battery Disconnect 14 Scrub Deck 1 2 3 4 5 6 7 8 10 11 12 14 15 16 17 18 19 20 21 22 23 24 9 26 26 ON ...

Page 6: ...e Indicator D Scrub Pressure Decrease Switch E Scrub Pressure Increase Indicator F Scrub Pressure Increase Switch G Scrub Pressure Hourmeter Display H Wand Switch Indicator I Wand Switch J Key Switch K Battery Condition Indicator L Speed Select Switch M Speed Select Indicator N Horn Switch O Vacuum Switch P Vacuum System Indicator Q Solution System Indicator R Solution Switch ...

Page 7: ...is vented from inside the batteries through openings in the battery caps This gas can be ignited by any electrical arc spark or flame When Servicing Batteries Remove all jewelry Do not smoke Wear safety glasses a rubber apron and rubber gloves Work in a well ventilated area Do not allow tools to touch more than one battery terminal at a time CAUTION Electrical components in this machine can be sev...

Page 8: ...cotter pins INSTALL THE SQUEEGEE 1 Make sure the Squeegee 19 is up O and the Key Switch J is off O Hold the squeegee tool so that the curved ends point forward then slide the squeegee tool onto the Mount A See Figure 2 2 Hand tighten the Thumb Nuts B and then connect the vacuum hose to the Squeegee Tube C vacuum hose should loop to the right 3 Lower the squeegee move the machine ahead slightly and...

Page 9: ...or V The detergent flow rate increases or decreases with the solution flow rate but the detergent ratio remains the same During scrubbing the detergent system can be turned off at any time by pressing the Detergent ON OFF Switch S to allow scrubbing with water only The solution flow rate is controlled by the Flow Rate Switch T whether the detergent system is ON or OFF The machine defaults to the E...

Page 10: ...A 10 FORM NO 56041988 Adgressor Adgressor EcoFlex A 10 ENGLISH DETERGENT SYSTEM PREPARATION AND USE ECOFLEX MODELS ONLY S FRONT T AA BB V U W X Y ...

Page 11: ...bbing check behind the machine occasionally to see that all of the waste water is being picked up If there is water trailing the machine you may be dispensing too much solution the recovery tank may be full or the squeegee tool may require adjustment 9 EcoFlex models only The machine defaults to the EcoFlex cleaning mode EcoFlex Switch Indicator X is lit GREEN conserving solution and detergent Pre...

Page 12: ...ve the squeegee rinse it with warm water and re install on mount 6 Remove the hopper on cylindrical systems and clean thoroughly Remove from either side of the machine by opening the skirt and tilting the hopper up and away from housing then pull out 7 Check the maintenance schedule below and perform any required maintenance before storage MAINTENANCE SCHEDULE MAINTENANCE ITEM Daily Weekly Monthly...

Page 13: ...of the filler tubes WARNING Do not fill the batteries before charging Only charge batteries in a well ventilated area Do not smoke while servicing the batteries CAUTION To avoid damage to floor surfaces always wipe water and acid from the top of the batteries after charging CHECKING THE BATTERY ELECTROLYTE LEVEL Check the electrolyte level of the batteries at least once a week After charging the b...

Page 14: ...tool off the floor then loosen the 2 Thumb Nuts C on top of the squeegee and remove the squeegee tool from the mount 2 Loosen the Front Squeegee Blade Removal Thumb Nut D then remove Tension Strap E and blade 3 The squeegee blade has 4 working edges Turn the blade so a clean undamaged edge points toward the front of the machine Replace the blade if all 4 edges are nicked torn or worn to a large ra...

Page 15: ...y are nicked torn or worn beyond their ability to be adjusted 4 Reinstall the skirt housing assemblies onto the machine and adjust the blade for proper contact to the floor when the brush deck is placed in the scrub position SIDE SKIRT HEIGHT ADJUSTMENT DISC SYSTEM 1 The side skirt housing knob retainer screw studs have leveling Adjuster Collars C that are to be raised or lowered to compensate for...

Page 16: ...ng normal use the blades will wear in time The operator will notice a small amount of water leaking out underneath the side skirts Skirt height adjustment is automatic on this system The skirt assemblies should move up and down freely for proper operation To replace the scrub system side skirt s 1 See Figure 5 Remove the 2 A Cotter Pins and swing the Skirt Assemblies open Remove the B Screws and N...

Page 17: ... valves Solution solenoid valve Clean or replace valve Machine does not run Emergency stop switch tripped Reconnect battery connectors Operator seat safety switch Check for open circuit and replace Main system controller Check error fault codes see service manual Tripped 10 Amp circuit breaker Check for electrical short circuit reset No FWD REV wheel drive Drive system speed contoller Check error ...

Page 18: ...tions at the Seat EN 1032 m s2 0 35m s2 0 35m s2 0 35m s2 0 35m s2 Gradeability Transport 20 11 5o 20 11 5o 20 11 5o 20 11 5o Cleaning 8 4 6o 8 4 6o 8 4 6o 8 4 6o Model Adgressor 2820C Adgressor 3220C Adgressor 3520C Adgressor 3820C Model No 56390902 56390906 56390910 56390914 Voltage Batteries V 36V 36V 36V 36V Battery Capacity Ah 415 415 415 415 Protection Grade IPX3 IPX3 IPX3 IPX3 Sound Power L...

Page 19: ...tions at the Seat EN 1032 m s2 0 35m s2 0 35m s2 0 35m s2 0 35m s2 Gradeability Transport 20 11 5o 20 11 5o 20 11 5o 20 11 5o Cleaning 8 4 6o 8 4 6o 8 4 6o 8 4 6o Model Adgressor X2820C Adgressor X3220C Adgressor X3520C Adgressor X3820C Model No 56381001 56381003 56381005 56381007 Voltage Batteries V 36V 36V 36V 36V Battery Capacity Ah 415 415 415 415 Protection Grade IPX3 IPX3 IPX3 IPX3 Sound Pow...

Page 20: ...tro Autorizado de Servicio Advance que utiliza personal de servicio formado en fábrica y lleva un inventario de piezas de repuesto y accesorios Advance originales Llame al DISTRIBUIDOR ADVANCE que se indica a continuación para lo referente a piezas de repuesto y servicio Por favor especifique el Modelo y Número de Serie cuando hable de su máquina Distribuidor coloque aquí la pegatina de su servici...

Page 21: ...los que apoyar la máquina No aplique sustancias limpiadoras inflamables ni utilice la máquina sobre estas sustancias cerca de ellas ni en zonas en las que haya líquidos inflamables No lave la máquina con una limpiadora a presión Use solamente los cepillos suministrados junto con el aparato o aquellos especificados en el manual de instrucciones El uso de otros cepillos puede afectar a la seguridad ...

Page 22: ...l freno freno de estacionamiento 7 Palanca de control del flujo de la solución 8 Pedal de tracción dirección velocidad 9 Tolva sólo modelos cilíndricos 10 Rueda de tracción y de dirección 11 Disyuntor del motor de la tracción de rueda 12 Disyuntor del circuito de control 13 Conmutador de parada de emergencia desconexión de la batería 14 Portacepillos 1 2 3 4 5 6 7 8 10 11 12 14 15 16 17 18 19 20 2...

Page 23: ...ndicador de aumento de la presión de fregado F Interruptor de aumento de la presión de fregado G Pantalla de presión de fregado cronómetro H Indicador del interruptor de la vara I Interruptor de la vara J Conmutador de llave K Indicador de situación de las baterías L Interruptor de selección de velocidad M Indicador de selección de velocidad N Interruptor del claxon O Interruptor de aspiración P I...

Page 24: ... tapas de las baterías gas explosivo de hidrógeno Este gas puede incendiarse con cualquier arco eléctrico chispa o llama Cuando revise las baterías Quítese todas las joyas No fume Lleve gafas de seguridad un delantal de goma y guantes de goma Trabaje en una zona bien ventilada No permita que las herramientas toquen simultáneamente más de un terminal de batería PRECAUCIÓN Los componentes eléctricos...

Page 25: ...NSTALACIÓN DE LA BOQUILLA 1 Asegúrese de que la boquilla 19 está arriba O y que el conmutador de llave J está apagado O Sostenga la boquilla de forma que los extremos curvados apunten hacia delante y a continuación deslice la boquilla en el montaje A Ver la Figura 2 2 Apriete a mano las tuercas de palomilla B y a continuación conecte la manguera de aspiración al tubo de la boquilla C la manguera d...

Page 26: ...e con el flujo de la solución pero índice del detergente no varía Durante el fregado el sistema de detergente puede apagarse en cualquier momento pulsando el conmutador de detergente S para permitir el fregado sólo con agua El flujo de solución está controlado por el conmutador de la solución T independientemente de si el sistema de detergente está encendido o apagado La máquina de manera predeter...

Page 27: ...FORM NO 56041988 Adgressor Adgressor EcoFlex B 9 ESPAÑOL B 9 REPARACIÓN Y USO DEL SISTEMA DE DETERGENTE ECOFLEX S FRONT T AA BB V U W X Y ...

Page 28: ...compruebe de vez en cuando que detrás de la máquina se está recogiendo el agua residual Si queda agua en la trayectoria de la máquina puede que esté aportando demasiada solución que el depósito de recuperación esté lleno o que la boquilla necesite un ajuste 9 Exclusivamente para modelos EcoFlex La máquina de manera predeterminada pasa al modo de limpieza EcoFlex indicador del interruptor EcoFlex X...

Page 29: ...y límpiela completamente Retírela de cada lado de la máquina abriendo la faldilla e inclinando la tolva hacia arriba y hacia fuera del contenedor luego tire de ella para sacarla 7 Compruebe el programa de mantenimiento que viene a continuación y realice cualquier operación de mantenimiento necesaria antes de guardar la máquina PROGRAMA DE MANTENIMIENTO OPERACIÓN DE MANTENIMIENTO Diaria Semanal Men...

Page 30: ...VERTENCIA No rellene las baterías antes de recargarlas Recargue las baterías exclusivamente en una zona bien ventilada No fume mientras maneja las baterías PRECAUCIÓN Para evitar daños a la superficie del suelo después de la recarga limpie siempre el agua y el ácido de la parte superior de las baterías COMPROBACIÓN DEL NIVEL DE ELECTROLITOS DE LAS BATERÍAS Compruebe el nivel de electrolitos de las...

Page 31: ...ión suelte las 2 tuercas de mariposa C de la parte superior de la rasqueta y retire la rasqueta del montaje 2 Retire la tuerca de mariposa de retirada de la hoja de rasqueta delantera D y luego retire la correa de tensión y la hoja E 3 La hoja de la rasqueta tiene 4 bordes de trabajo Gire la hoja de manera que un borde limpio e intacto apunte hacia la parte frontal de la máquina Sustituya la hoja ...

Page 32: ...Vuelva a montar los conjuntos de alojamiento de las faldillas en la máquina y ajuste la cuchilla para que haga contacto correctamente con el suelo al poner el portacepillos en posición de fregado AJUSTE DE LA ALTURA DE LA FALDILLA LATERAL SISTEMAS DE DISCOS 1 Los espárragos de sujeción de los alojamientos de las faldillas laterales disponen de collarines de ajuste de nivelación C que tienen que le...

Page 33: ...esgastando con el tiempo El operador verá que una pequeña cantidad de agua sale por debajo de las faldillas laterales En este sistema el ajuste de la altura de las faldillas es automático Para que funcionen correctamente los conjuntos de las faldillas deben moverse libremente hacia arriba y hacia abajo Para sustituir la s faldilla s lateral es del sistema de fregado 1 Ver la Figura 5 Retire los 2 ...

Page 34: ... solución Limpie o sustituya la válvula La máquina no funciona Interruptor de parada de emergencia disparado Vuelva a enchufar los conectores de las baterías Interruptor de seguridad del asiento del operador Compruebe si hay algún circuito abierto y sustitúyalo Controlador principal del sistema Compruebe los códigos de averías véase el manual de servicio Disyuntor de 10 amp desconectado Compruebe ...

Page 35: ...ón en el asiento EN 1032 m s2 0 35m s2 0 35m s2 0 35m s2 0 35m s2 Capacidad ascendente Transporte 20 11 50 20 11 50 20 11 50 20 11 50 Limpieza 8 4 60 8 4 60 8 4 60 8 4 60 Modelo Adgressor 2820C Adgressor 3220C Adgressor 3520C Adgressor 3820C Nº Modelo 56390902 56390906 56390910 56390914 Voltaje baterías V 36V 36V 36V 36V Capacidad baterías Ah 415 415 415 415 Grado de protección IPX3 IPX3 IPX3 IPX3...

Page 36: ...bración en el asiento EN 1032 m s2 0 35m s2 0 35m s2 0 35m s2 0 35m s2 Capacidad ascendente Transporte 20 11 5o 20 11 50 20 11 50 20 11 50 Limpieza 8 4 6o 8 4 60 8 4 60 8 4 60 Modelo Adgressor X2820C Adgressor X3220C Adgressor X3520C Adgressor X3820C Nº Modelo 56381001 56381003 56381005 56381007 Voltaje baterías V 36V 36V 36V 36V Capacidad baterías Ah 415 415 415 415 Grado de protección IPX3 IPX3 ...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...14600 21st Avenue North Plymouth MN 55447 3408 www advance us com Phone 800 989 2235 Fax 800 989 6566 2010 Nilfisk Advance Inc A Nilfisk Advance Brand ...