Scrub System 177
Service Manual – Advance 7765 / Nilfisk CR1500
Scrub Deck Down at High Scrub Pressure
When the Scrub Brush Lift Switch is set to the down position and the Brush Pressure Switch is set to the
lower (high-pressure) position, the
Scrub Brush Lock Up Solenoid (9)
and
Scrub Brush Solenoid (8)
will be
energized. This allows the oil to flow from the discharge side of the
Power Steering Unit
through the
Scrub
Brush Solenoid (8)
valve, then to the upper port on the
Scrub Deck Cylinder
. This forces the scrub deck down to
the heavy scrub pressure. The
Check Valve
maintains the circuit pressure at 270 psi.
The oil from the lower port on the
Scrub Deck Cylinder
has a open path through the energized
Scrub Brush
Lock Up Solenoid (9)
valve and the de-energized
Scrub Brush Solenoid (6)
valve to the return line to the
Reservoir
.
To and From
Squeegee Hydraulic
Deck Cylinder
Scrub
Deck
Cylinder
C3
C4
C2
C1
1.02
CIR
Check Valve
270 PSI
Reservoir
Auxiliary
Pump
8.2 GPM
1.5 GPM
Cylinder
Control
Valve
P
To Squeegee
Vacuum Motor
Scrub Brush
Solenoid (6)
Scrub Brush
Solenoid (8)
Scrub Deck
Moves Down
Under Pressure
Squeegee
Cylinder
Solenoid (7)
Squeegee
Lock Up (10)
Scrub Brush
Lock Up
Solenoid (9)
Power
Steering
Unit
1500
PSI
3.1
CIR
P
T
Power Steering
Cylinder
L
R
Summary of Contents for 56514925
Page 28: ...General Information 28 Service Manual Advance 7765 Nilfisk CR1500 Maintenance Item Locations ...
Page 74: ...Engine System common Electrical System 74 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 89: ...Engine System Diesel 89 Service Manual Advance 7765 Nilfisk CR1500 Starter Relay ...
Page 113: ...Engine System Gasoline LPG 113 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 114: ...Engine System Gasoline LPG 114 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 115: ...Engine System Gasoline LPG 115 Service Manual Advance 7765 Nilfisk CR1500 ...