7.2.4 Weekend programming
This program allows you to set two time periods which apply for both Saturday and Sunday.
Enter menu 2, press button 5 (three times) and confirm with button 3 to enter menu 2-4, the weekend
programming menu. Use button 5 to scroll through the different settings within this menu in the order shown
in the table below (n2-4-01 to n2-4-05). Use the buttons 1 and 2 to change the respective values.
WEEKEND PROGRAMMING
menu level
setting
meaning
available values
n2-4-01
WEEKEND CHRONO
Enable weekend chrono
ON/OFF
n2-4-02
START 1
Start time
OFF-00:00-23:50
n2-4-03
STOP 1
Stop time
OFF-00:00-23:50
n2-4-04
START 2
Start time
OFF-00:00-23:50
n2-4-05
STOP 2
Stop time
OFF-00:00-23:50
7.3 Language settings
Enter the language setting menu by pressing button 3, followed by button 5 two times. Confirm with button 3
to enter menu 03. You can now choose between 6 languages: English, Italian, Dutch, Spanish, French and
German. Use buttons 1 and/or 2 to change the language and button 4 to exit once the correct language is
visible on the display.
7.4 Stand-by mode
The STAND-BY mode allows the stove to automatically turn off when the measured temperature exceeds
the set room temperature with 2 °C and will turn back on when the measured room temperature is 2 °C
below the set room temperature.
Enter menu 4 and change between ON and OFF by pressing button 1 or 2. Exit with button 4.
7.5 Sound alerts
The stove will make you aware of any potential alerts with a beep sound.
In order to activate or deactivate this sound alert, enter menu 5 and change between ON and OFF by
pressing button 1 or 2. Exit with button 4.
7.6 Initial pellet loading
After filling the pellet container with pellets for the first time, the auger needs to be filled with pellets. To do so
press button 3, followed by button 5 five times. Confirm with button 3 to enter menu 06
– the display now
shows 06 P1 TO LOAD. Press button 1 to start the initial pellet loading
– a 90 sec countdown will start. Stop
the process by pressing button 4 when the first pellets appear in the brazier. If no pellets have reached the
brazier after 90 seconds, please repeat the initial pellet loading.
Whenever the pellet container runs empty during operation, ALARM 6 will appear on the display (see also
Potential Errors). In this case, carry out the above described procedure as well.