The U-BR1TE with power plugs into a single channel slot of a Total Access
®
1500
chassis. It provides an ISDN U-interface and allows the transport of Basic Rate 2B+D
information over T1 carriers. The U-BR1TE features:
■
18kft nominal range in mixed gauge wire
■
ISDN 2B1Q interface
■
Internal testing of individual B channels
■
All Layer 1 maintenance functions
■
Provides repeater powering and DDS IDSL support
INSTALLATION AND TURN-UP
Unpack the Total Access 1500 U-BR1TE access module and inspect for damage. If
damage is has ocurred, file a claim with the carrier and then contact ADTRAN.
Verify SW1 is provisioned properly for the intended application. Refer to the table
below for default provisioning and other provisioning options. Make changes to
SW1 options as necessary.
SW SETTINGS
Switch Label
Function/Description
SW1-1
LULT/LUNT
Termination Mode
*ON…LULT Mode (RT Typical)
OFF…LUNT Mode (COT Typical)
SW1-2
SX
Sealing Current
*ON…DC sealing current provided
(Adjacent to switch or customer)
OFF…DC sealing current not provided (Tandem office installation)
SW1-3
B1
Service Level Station (Enables B1 Channel)
SW1-4
B2
(Enables B2 Channel)
SW1-5
D
(Enables D Channel)
Service
SW1-3
SW1-4
SW1-5
Option
(B1)
(B2)
(D)
2B+D
*ON
*ON
*ON
2B
ON
ON
OFF
B1+D
ON
OFF
ON
B2+D
OFF
ON
ON
B1
ON
OFF
OFF
B2
OFF
ON
OFF
D
OFF
OFF
ON
SW1-6
ZBS
Zero Byte Substitution
ON....Enable ZBS
*OFF…Disable ZBS
SW1-7
PWR ON
Enables Repeater Powering
* Factory Default
Insert U-BR1TE access module into a Total Access 1500 chassis slot 1-24. To insert,
hold the U-BR1TE access module by the front panel while supporting the bottom
edge of the module. Align the access module edge with the guide groove in the Total
Access 1500 chassis. Insert into chassis until the edge module connector seats
firmly into the chassis backplane. Lock the access module in place by pushing in on
the locking lever.
Monitor Status LED for operational status.
LED STATUS
STATUS
●
●
Off
Indicates both loop and carrier synchronization have
been established
●
Red
Solid indicates neither loop nor carrier synchronization
has been established.
✷
✷
Flashing
Once every two seconds indicates loop synchronization
has been established, but carrier synchronization has not.
✷✷
✷✷
Flashing
Twice every second indicates carrier synchronization has
been established, but loop synchronization has not.
●
Green
Indicates that Layer 1 is established from the ISDN switch
to the customer ISDN terminal equipment.
●
Yellow
Solid when a front panel test has been initiated or when
responding to 2B+D loopback request.
✷
✷
Flashing
Flashes once every two seconds when responding to a B1
loopback request.
✷✷
✷✷
Flashing
Flashes twice every two seconds when responding to B2
loopback request.
REM
●
Green
Indicates the unit has been provisioned by the SCU.
AP PUSHBUTTON
AP
Pushbutton
Alternative provisioning switch. Changes provisioning
source from remote to manual.
PROVISIONING
The Total Access 1500 supports two types of provisioning modes, local and
remote. Local provisioning results in the unit operating as defined by the
onboard switches. Remote provisioning, if chosen, results in the unit operating as
defined by the system controller menu settings (onboard switches are ignored).
The operational mode is indicated by the REM LED and can be changed by
activating the AP (Alternate Provisioning) front panel switch
Connect VT100 compatible terminal to SCU front panel ADMIN port. The ADMIN
port issued for provisioning, testing, and performance monitoring functions.
■
Connect DB-9 cable
■
Run terminal emulation program
■
If using Windows HyperTerminal, open by selecting
Programs/Accessories/Hyperterminal
■
Login and navigate through ADMIN port menu structure
NOTE
: To ensure proper display background, select VT100 Terminal Emulation
under settings.
■
For a complete Installation and Maintenance Practice (P/N 61180020L2-5): 877-457-5007,
Faxback Document 942. Please have your fax number ready.
■
LUL
T
LUNT
SX
B1
B2
1
1
1
O
N
O
N
O
N
O
N
2
2
2
3
3
3
4
4
4
D
ZBS
PWR
5
5
5
6
6
6
7
7
7
1
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
2
3
4
5
6