Summary of Contents for TRACER 5045

Page 1: ...l located on the rear panel of the unit near the Antenna connector Record the current configuration before beginning this procedure Tools and Materials Required 5 16 Torque wrench 8 in lbs 3 16 nut driver Phillips head screw driver Disconnect all cables attached to the TRACER 5045 system including power data terminal RS 232 etc before performing this procedure Do not attempt to perform the convers...

Page 2: ...on either side of the RS 232 connector on the rear panel of the unit using the 3 16 nut driver see Figure 2 Figure 2 Removing the RS 232 Nuts 3 Carefully slide the cover toward the back of the unit until the front edge of the cover is disconnected from the front of the unit Lift the cover off and set aside Perform the steps below in the order listed Remove all connected mounting brackets before at...

Page 3: ...t to disconnect the J connectors located on the board as this will cause damage Click here for a digital picture of this step 6 Carefully flex the cables to swap the connections Be careful with the RF cables making sure that the minimum bend radius of the cable is greater than 0 75 bends and loops smaller than a quarter will cause the RF cable to break Use the wiring guidelines in Figure 3 for hel...

Page 4: ...ectors Tighten the cables by turning clockwise until you hear a click from the wrench DO NOT overtighten connectors as this will cause the RF cable to break The TRACER 5045 system will not operate properly with broken RF cables 8 Reinstall the cover and carefully tighten all screws 9 Change label on back of the unit to reflect the Plan change ...

Page 5: ... BACK ...

Page 6: ... BACK ...

Page 7: ... BACK ...

Page 8: ... BACK ...

Page 9: ... BACK ...