background image

1

61291004L2-5, Issue 2

61291004L2-5B

TRDDB

Total Reach

®

 Digital Data Bank Channel Unit

Installation and Maintenance

Section 61291004L2-5B

Issue 2, November 2000

CLEI Code # D4C4EEJB_ _

Figure 1.  Total Reach DDB

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN D4 Total Reach

®

 Digital

Data Bank (TRDDB) channel unit.  

Figure 1

 is an

illustration of the ADTRAN TRDDB
(P/N 1291004L2).

Revision History

Issue 2 of this document includes an edge connector
pinout illustration.

Features

• 2-wire deployment

• Repeaterless operation

• Bridged tap tolerant

• Span power for remote Total Reach OCU-R

(TROCU-R) termination unit

• Embedded Digital System 6 capabilities for

remote provisioning, configuration, and
performance monitoring

Trademarks:  Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

CONTENTS

1. GENERAL ........................................................... 1
2. INSTALLATION ................................................ 2
3. TESTING ............................................................. 5
4. REMOTE PROVISIONING AND

DIAGNOSTICS ................................................... 7

5. DEPLOYMENT GUIDELINES ......................... 8
6. MAINTENANCE ................................................ 9
7. WARRANTY AND CUSTOMER SERVICE .... 9

FIGURES

Figure 1.

Total Reach DDB ..................................... 1

Figure 2.

DS0 Level Test Access for DDS
Customers w/ 2 End Points Served from
Same CO .................................................. 2

Figure 3.

Multipoint DDS Deployment ................... 3

Figure 4.

Back-Hauled IXC T1 to DDS .................. 3

Figure 5.

Connector Pin Assignments ..................... 3

Figure 6.

Rate Selection and Option Switch ........... 4

Figure 7.

TRDDB Bidirectional Loopback
Pass-Thru Mode ....................................... 6

Figure 8.

TRDDB Bidirectional Loopback
Normal Mode ........................................... 6

Figure 9.

TROCU-R Remote End Initiated
Loopback, Local Loop ............................. 7

Figure 10. TROCU-R Remote End Initiated

Loopback, Customer Loop ....................... 7

TABLES

Table 1.

Compliance Codes ................................... 3

Table 2.

LED Indicators ......................................... 4

Table 3.

Protected Loopback Mode Requirement
T1E1.2/99-007R1 (Latching Loopback) .. 5

Table 4.

Cable Type and Temperature Loss Data
@ 13.3 kHz .............................................. 5

Table 5.

Latching Loopback Activation Sequence 6

Table 6.

Alternating Loopback Activation
Sequence .................................................. 6

Table 7.

Total Reach DDS Insertion Loss
Measurements .......................................... 8

AP

TRDDB

1291004

L

O
G

I

C

Rx

(OUT)

Tx

(IN)

ON

SC

NO

SX

CRC

QM

DISC

SYNC

REM

LBK

NO

DSU

64

56

19.2

9.6

4.8

2.4

QM

LLB

DDS

Summary of Contents for Total Reach TRDDB

Page 1: ...NSTALLATION 2 3 TESTING 5 4 REMOTE PROVISIONING AND DIAGNOSTICS 7 5 DEPLOYMENT GUIDELINES 8 6 MAINTENANCE 9 7 WARRANTY AND CUSTOMER SERVICE 9 FIGURES Figure 1 Total Reach DDB 1 Figure 2 DS0 Level Test Access for DDS Customers w 2 End Points Served from Same CO 2 Figure 3 Multipoint DDS Deployment 3 Figure 4 Back Hauled IXC T1 to DDS 3 Figure 5 Connector Pin Assignments 3 Figure 6 Rate Selection an...

Page 2: ...ons NEAR and FAR logic level Bantam test access Loop Quality Monitor and latching loopback Description The ADTRAN D4 TRDDB is a 2 wire Total Reach DDS functional replacement for the following ADTRAN 4 wire OCU part numbers 1104004L3 D4OCBRD2AA 1104004L4 D4OCBRE2AA 1105004L1 D4OCBSD2AA 1105004L2 D4OCBSE2AA 1105018L1 D4OCBTD2AA The TRDDB delivers data at rates up to 64 kbps using a single copper pai...

Page 3: ... Figure 5 for pinout assignments Code Input Output Power Code PC F C Telecommunication Code TC X Installation Code IC A Table 1 Compliance Codes Figure 5 Connector Pin Assignments Figure 4 Back Hauled IXC T1 to DDS DS0 DS0 IXC T1 DS0 DP TR OCU R DSU CSU GPC D4 or SLC96 TR DDB Test Head 2 wire Loop 50 kft Customer Premises CO Figure 3 Multipoint DDS Deployment DS0 DS0 DS0 DS0 DS0 IXC T1 DS0 DP MJU ...

Page 4: ...DTRAN s Protected Loopback mode Protected Loopback ADTRAN s Protected Loopback supports the DDS latching loopback standard in T1E1 2 99 007R1 When enabled the TRDDB will respond to latching loopback when the idle code preamble is sent prior to the latching loopback sequence specified in TR62310 and ANSI T1 417 See Table 3 for the latching loopback sequence requirement when Protected Loopback is en...

Page 5: ... 1 C I P e g u a G 2 2 2 1 9 0 8 5 2 0 1 5 1 0 1 1 F 0 P L U P e g u a G 2 2 F 0 7 P L U P e g u a G 2 2 F 0 2 1 P L U P e g u a G 2 2 4 5 4 9 0 6 0 6 0 1 0 7 3 1 1 F 0 C I P e g u a G 4 2 F 0 7 C I P e g u a G 4 2 F 0 2 1 C I P e g u a G 4 2 1 7 5 2 1 2 8 9 3 1 7 1 9 4 1 F 0 P L U P e g u a G 4 2 F 0 7 P L U P e g u a G 4 2 F 0 2 1 P L U P e g u a G 4 2 0 0 9 2 1 4 2 3 4 1 8 6 2 5 1 F 0 C I P e g...

Page 6: ... t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R g n i t s i x e r a e l C s k c a b p o o l e c i v e d y f i t n e d I d e p o o l e b o t p o o l o t e r a p e r P e d o c P A M d n e s s e t y b 0 3 r e t f a e t a v i t c A k c a b p o o l n i n o i t i s n a r T P I T s s e r g o r p 0 1 0 1 1 1 0 X t c e l e s k c...

Page 7: ...al Reach system latching loopbacks whether initiated by the craft interface LBK pushbutton or via the Test Center or CO may be disabled by sending 35 TIP bytes X0111010 where X is a don t care All existing latching loopbacks may also be disabled by pressing the LBK pushbutton on the CO or remote units 4 REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Remote access to provisioning and status i...

Page 8: ...rmation stored in 15 minute and 24 hour registers for both the TRDDB and TROCU R and an event log which time stamps system performance anomalies and threshold violations Physical access to the terminal interface on the TROCU R is made by a serial interface connection to a dumb terminal or dumb terminal emulation Provisioning of the TRDDB can be viewed and changed from the terminal interface on the...

Page 9: ...cy and Procedure document 60000087 10A Contact Customer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Presales Applications Postsales Technical Assistance 888 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency h...

Page 10: ...10 61291004L2 5 Issue 2 61291004L2 5B ...