61182118L1-5B
Issue 2, July 2004
7
Table 3
lists the factory default values for each of the
2W/4W SHDSL LTU provisioning options.
Table 3. Default Provisioning Values
Provisioning Options
Values
Default
Unit Options
Line Card Service State
In Service
Out of Service - Unassigned
Out of Service - Maintenance
Out of Service - Maintenance
Cross-Connect Map
For each timeslot assignment:
0 = unassigned, idle pattern transmitted
out of associated port
1 = G.703
32 = G.704 CCS Framing timeslot
Full G.703 Service with
G.704 Framing = NT Delivered
LT Mode Clk Source
Internal Clock
G.703 RX Clock
SHDSL RX Clock
Internal Clock
External Port Alarms
Disabled
Enabled
Disabled
NTU Auto Provisioning
Disabled
Enabled
Disabled
SHDSL Options
Interface Mode
2-wire
4-wire
2-wire
Payload Rate (kbps)
Enter a new value for N from 3 to 32,
where Payload Rate (kbps) = N x 64
2048 (N=32)
SNR Margin Alarm Threshold (dB)
Disabled
1-15 Threshold in dB
Disabled
Loop Attenuation Alarm Threshold (dB)
Disabled
1-127 Threshold in dB
Disabled
Outage Auto-Retrain
Disabled
Enabled
Disabled
PM Thresholds
See below for Loop 1 and Loop 2
ES 15 Minute Alarm Threshold
Disabled
1 to 900 = Alarm Threshold
Disabled
SES 15 Minute Alarm Threshold
Disabled
1 to 900 = Alarm Threshold
Disabled
UAS 15 Minute Alarm Threshold
Disabled
1 to 900 = Alarm Threshold
Disabled
CVC 15 Minute Alarm Threshold
Disabled
1 to 65535 = Errors
Disabled
LOSWS 15 Minute Alarm Threshold
Disabled
1 to 900 = Alarm Threshold
Disabled