16
61181031L3-5A
Fail
Fail is displayed when an External clock failed while
provisioned for External Clock Source.
Figure 10. Status Menu
Unused, Unavailable
Unused, Unavailable is displayed when no external
Clock is present and is not provisioned for External
Clock Source.
Unused, Available
Unused, Available is displayed when an External Clock
is present but is not provisioned for External Clock
Source.
SEC EXT Clock
The SEC EXT Clock field displays the status of the
Secondary External Clock. The possible options are the
same as those for the Primary External Clock listed
above.
OC-3 Line Status
The OC-3 Line Status field displays the status of the
OC-3 Line as one of the following:
TX and RX Fail
TX and RX Fail indicates that one or more failures have
been detected on both the transmit and receive side.
TX Fail
TX Fail indicates that one or more failures have been
detected on the transmit side.
RX Fail
RX Fail indicates that one or more failures have been
detected on the receive side.
Normal
Normal indicates that no failures are detected.
APS Status
The APS Status field displays the status of the DS1
Drop (Clock Controller) and the two DS3 interfaces,
which in turn provides the setting of the module for
APS. The possible settings are as follows:
Shelf: 1 Slot: B Total Access System 01/13/03 09:37
Unacknowledged Alarms: None
Status
Mux Service State : OOS-M Clock Status : Holdover
Active Loops : No Loops Selected Clock : Receive OC-3 A
OC-3 DCC : Link Down PRI EXT Clock : Unused, Unavailable
Local DS3 Framing : M13 SEC EXT Clock : Unused, Unavailable
OC-3 Line Status : RX Fail
Path #1 Service State : OOS-M
Path #2 Service State : OOS-U DS3 #1 APS Status : Online/Allow
Path #3 Service State : OOS-U DS3 #2 APS Status : Online/Allow
DS3 #1 Service State : OOS-U DS1 Drops APS Status : Online/Allow
DS3 #2 Service State : OOS-U Active OSI Stack : Mux B
'?' - System Help Screen