background image

2

61287733F1-22E

1. Route the Power Cable through the Power Entry Port located at the base 

of the MDU Housing (see 

Figure 1

).

2. Attach the two power leads (Pins 1 and 2) and if needed, the five alarm 

status leads to the Power Connector (P/N: 3202007CN01-E).

3. Attach the Power Connector to the 

P1 

Connector in the Power 

Distribution Block. 

ONT Installation Overview

There are two types of ONTs that can be installed in the MDU. Those are illus-
trated in 

Figure 3

.

Installing an ONT consists of the following steps:

Step 4a: Total Access 374 installation

Step 4b: Total Access 352(H) or 362 installation

Step 5: Connect Power to the ONTs

Step 6: Route Internet Services Cables

Figure 3. ONTs

The ONT Support Bracket (P/N 3267140-E, 

Figure 4

) is used by all ONTs when 

attaching to the MDU Housing. These bracket are pre-installed in the MDU 
Housing when shipped.

Figure 4. ONT Support Bracket

Step 4a: Total Access 374 installation

To install the Total Access 374 ONT, complete the following steps:

1. Refer to 

Figure 3

 and loosen the “Telco Access Only” nut on the Total 

Access 374 ONT Cover, and open the Cover.

2. Refer to 

Figure 2

 and attach the 7-Pin Plug (P/N: 3202007CN00-E) to the 

Cable Assembly (P/N: 3125P135-E) per the WIRE CHART in 

Figure 2

.

3. Insert the Cable Assembly in to the ONT Circuit Card Power Connector 

illustrated in 

Figure 5

.

4. Refer to 

Figure 1

 and loosen the Bracket Mounting Screw holding the 

Support Bracket to the MDU Housing. Remove the Support Bracket.

5. Align the ONT Mounting Tabs (

Figure 4

) on the ONT Support Bracket 

with the ONT Bracket Mount Points on the ONT (

Figure 5

)

POTS 2

POTS 1

TELCO ACCESS

ETH 1

TOTAL ACCESS 351

1287701G1

12V     , 1.25A

POWER

NETWORK STATUS

TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
    any working telephone into that jack.
      If the telephone works, there is a problem inside the house.
      If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.

TEL. NUMBER

TIP/RING

+ 12VDC

12V R

T

N

SIG R

T

N

ON BA

T

REP

 BA

T

BA

T

 MIS

LOW BA

T

7

6

5

4

3

2

1

Total Access 374

Total Access 352, 352H or 362

“Telco Access 
Only” Nut

Bracket Mounting 
Rail

ONT Mounting Tabs

Bracket Mounting 
Screw

Total Access 352, 352H and 
362 ONTs Circuit Card 
Mounting Point

Total Accss 374 ONT Mounting Point

PEM Nut for ground
wire connection

Step 1: Mount the MDU

CAUTION

!

The MDU should only be installed by qualified service personnel.

Consideration should be given to proper clearances for opening the MDU 
door. Ensure that the door can be opened completely.
To mount the MDU, complete the following steps:

1. For outdoor installation, choose a vertical surface near an approved 

ground, but away from down spouts, permanent water sprinklers, or 
other water sources. 

2. Use the top and bottom external mounting holes as a template to mark 

fastener locations. Use a level to ensure the unit is level and the door will 
open and close properly.

3. Pre-drill the marked locations and install two, 5/16 or 3/8-inch diameter 

lag bolts that are appropriate to secure the MDU to the mounting 
surface. The MDU housing with four ONTs, and associated cabling will 
weigh approximately 25 pounds.

4. Mount the MDU.

Step 2: Ground the MDU

WARNING

!

Use extreme care when attaching the ground connectors to the utility (earth)
ground rod. If the ground is interrupted or disturbed in any way, an unsafe
condition will exist. Refer to the National Electrical Code (NEC) and state and
local codes for details on grounding requirements.

Refer to 

Figure 1

 to ground the MDU.

1. Strip 5/8 of an inch of insulation from a 6 AWG ground wire and crimp 

the grounding lug (P/N 3198001PN21-E) to the wire using the appropri-
ate crimping tool (i. e., Burndy Type Y35).

2. Attach the Ground Lug at the right-rear of the MDU housing with 2 

Lock Washers (P/N 3284018-E) and 2 Screws (P/N 327611028-E).
a. Apply antioxidant to all grounding surfaces.
b. Attach ground lug with two #10 lock washers and two, 

10-32 x 3/8-inch machine screws.

c.

Torque the screws to 24 inch/pounds.

3. Apply the appropriate anti-oxidant and connect the opposite end of the 

ground wire to a reliable earth ground.

Step 3: Connect Power to MDU 

CAUTION

!

Do not turn the power source on until the MDU installation is complete. 

To connect power to the MDU, refer the Power Distribution Block (P1) in 

Figure 1

, the Wire Chart and PCB (P1) portion of 

Figure 2

 and complete the 

following steps:

Figure 2. Power Distribution

1     2      3     4     5     6     7

      4     3     2       1

      8     7      6      5