background image

2

61287564G1-22A

3. Refer to the illustration below and insert the CAT 6 rated 

cable in the ETH Port.

Step 3: Connect Fiber

CAUTION

C

LASER RADIATION
1310 nm to 1600 nm
Do not view directly with optical instruments.
This product contains a Class 1M Laser module that complies
with 21 CFR 1040.10 and 1040.11 and IEC 60825-1 and -2.

Fiber is installed in an SC/APC connecter located behind a 
removable protector panel on the right-rear of the Small Form 
Factor ONT. Refer to the figure below and the following steps to 
install fiber:

1. Remove the Protective Panel and slide the it back (in the 

direction of the dashed arrow) to expose the SC/APC con-
nector.

Ethernet RJ-45 Pin-out

Pin

Name

Description

Color

 

Code

1

TRD0+

Transmit/Receive

 

Positive

White/Orange

2

TRD0

Transmit/Receive

 

Negative

Orange

3

TRD1+

Transmit/Receive

 

Positive

White/Green

4

TRD2+

Transmit/Receive

 

Positive

Blue

5

TRD2

Transmit/Receive

 

Negative

White/Blue

6

TRD1

Transmit/Receive

 

Negative

Green

7

TRD3+

Transmit/Receive

 

Positive

White/Brown

8

TRD3

Transmit/Receive

 

Negative

Brown

ETH
Port

Fiber
Port

Protective
Panel

Required tools

Standard technician tools and those listed below are required for 
installing the Small Form Factor ONT:

PON power meter with wavelength filtering

Fiberscope or videoscope

Two #8 Pan Head screws (1 inch or greater in length)

Assorted tie wraps for securing cabling and wiring

For fiber optic connections, the following are required:

Fiber optical fusion splice tools

ODC Fiber cleaning tool

SC/APC Fiber connector

Installation Steps

To install the Small Form Factor ONT, refer to the following illus-
trations and complete the following steps.

Step 1: Install the Small Form Factor ONT

There are two options when installing the Small Form Factor 
ONT: Desk Top and Wall Mount. Both are described below.

Desk Top Installation

The Small Form Factor ONT can rest on a desktop or be wall 
mounted. With either a wall or desk mount, ensure the Small 
Form Factor ONT is not located in direct sunlight and is not 
located next to any thermal obstructions. 

Wall Mount Installation

To wall mount the Small Form Factor ONT, complete the 
following steps:

1. Decide on a location for the Small Form Factor ONT. 
2. Attach to drywall using the appropriate anchors.
3. Use the keyhole slots on the back of the Small Form Factor 

ONT as a template and install two #8 Pan Head screws (1 
inch or greater in length) using the key holes on the back of 
the Small Form Factor ONT as location markers. Leave 
approximately 1/4 inch protruding from the mounting 
surface.

4. Slide the Small Form Factor ONT over the Pan Head screws 

and exert a small amount of downward pressure to ensure 
that the top of the slots are resting on the shafts of the Pan 
Head screws

Step 2: Connect Ethernet 

The Small Form Factor ONT supports a Gigabit (10/100/
1000Base-T) connection (ETH). 
If an Ethernet cable is not available, use the following procedure 
and table at the top of the next column to create the Ethernet 
cable.

1. Use a CAT 6 rated cable and trim the insulation for the sub-

scriber Ethernet cable back approximately 1/2 inch.

2. Connect the wires per the following table using an RJ-45 

Crimper.