2
61287564G1-22A
3. Refer to the illustration below and insert the CAT 6 rated
cable in the ETH Port.
Step 3: Connect Fiber
CAUTION
C
LASER RADIATION
1310 nm to 1600 nm
Do not view directly with optical instruments.
This product contains a Class 1M Laser module that complies
with 21 CFR 1040.10 and 1040.11 and IEC 60825-1 and -2.
Fiber is installed in an SC/APC connecter located behind a
removable protector panel on the right-rear of the Small Form
Factor ONT. Refer to the figure below and the following steps to
install fiber:
1. Remove the Protective Panel and slide the it back (in the
direction of the dashed arrow) to expose the SC/APC con-
nector.
Ethernet RJ-45 Pin-out
Pin
Name
Description
Color
Code
1
TRD0+
Transmit/Receive
Positive
White/Orange
2
TRD0
‐
Transmit/Receive
Negative
Orange
3
TRD1+
Transmit/Receive
Positive
White/Green
4
TRD2+
Transmit/Receive
Positive
Blue
5
TRD2
‐
Transmit/Receive
Negative
White/Blue
6
TRD1
‐
Transmit/Receive
Negative
Green
7
TRD3+
Transmit/Receive
Positive
White/Brown
8
TRD3
‐
Transmit/Receive
Negative
Brown
ETH
Port
Fiber
Port
Protective
Panel
Required tools
Standard technician tools and those listed below are required for
installing the Small Form Factor ONT:
PON power meter with wavelength filtering
Fiberscope or videoscope
Two #8 Pan Head screws (1 inch or greater in length)
Assorted tie wraps for securing cabling and wiring
For fiber optic connections, the following are required:
Fiber optical fusion splice tools
ODC Fiber cleaning tool
SC/APC Fiber connector
Installation Steps
To install the Small Form Factor ONT, refer to the following illus-
trations and complete the following steps.
Step 1: Install the Small Form Factor ONT
There are two options when installing the Small Form Factor
ONT: Desk Top and Wall Mount. Both are described below.
Desk Top Installation
The Small Form Factor ONT can rest on a desktop or be wall
mounted. With either a wall or desk mount, ensure the Small
Form Factor ONT is not located in direct sunlight and is not
located next to any thermal obstructions.
Wall Mount Installation
To wall mount the Small Form Factor ONT, complete the
following steps:
1. Decide on a location for the Small Form Factor ONT.
2. Attach to drywall using the appropriate anchors.
3. Use the keyhole slots on the back of the Small Form Factor
ONT as a template and install two #8 Pan Head screws (1
inch or greater in length) using the key holes on the back of
the Small Form Factor ONT as location markers. Leave
approximately 1/4 inch protruding from the mounting
surface.
4. Slide the Small Form Factor ONT over the Pan Head screws
and exert a small amount of downward pressure to ensure
that the top of the slots are resting on the shafts of the Pan
Head screws
Step 2: Connect Ethernet
The Small Form Factor ONT supports a Gigabit (10/100/
1000Base-T) connection (ETH).
If an Ethernet cable is not available, use the following procedure
and table at the top of the next column to create the Ethernet
cable.
1. Use a CAT 6 rated cable and trim the insulation for the sub-
scriber Ethernet cable back approximately 1/2 inch.
2. Connect the wires per the following table using an RJ-45
Crimper.