ADTRAN Total Access 300 Series Quick Start Manual Download Page 4

Warranty

:

ADTRAN will replace or repair this product within the warranty period if it does not 

meet its published specifications or fails while in service. Warranty information can be 

found online at 

www.adtran.com/warranty

.

©2014 ADTRAN, Inc. All Rights Reserved.

*612877SBONT-22B*

7. Tie wrap all cables to the appropriate tie wrap anchor points.

Install Fiber

To install fiber to the ONT, refer to the illustration below and complete the 

following steps.

1. Remove the cover of the Fiber Tray (P/N 3353312-E) and install the 

tray using the two #6 screws (P/N 327600051-E) provided.

2. Route the fiber coming to the customer premise through the rubber 

grommet as shown.

3. Trim the insulation on the fiber cable back so there is a sufficient 

length of fiber to attach the fiber connector to the end of the fiber 

cable.

4. Loosen the cable support clamp and route the strength member 

through the clamp. Retighten the cable support clamp.

5. Clean all optical surfaces before and after splicing.
6. Splice the fiber to the fiber jumper cable (yellow) using a Fusion-

Type splice. DO NOT use a mechanical splice as this may create a 

reflection at the splice point.

7. Connect the fiber jumper cable to the connector at the bottom of the 

Electronics Module.

Install Coaxial Cable

The coaxial cable connection is located just to the right of the SC/APC 

Fiber Connection. 
To install the coaxial cable, complete the following steps.

1. Route the coaxial cable through the cable entry on the bottom of the 

enclosure.

2. Tie wrap the cable to the tie wrap points on the enclosure.
3. Attach the subscriber cable to the coaxial connector and tighten.

Ethernet LED Connectivity

Label

Status

Description

LINK

Off

Green

Link is down or Administratively 

shut down
10/100/1000 link is up

ACTIVITY

Off

Yellow Flashing

No activity, or Administratively 

Shut Down
TX or Rx activity

Fiber In

Note: Cable color for
clarity purposes only.

F

R

T

E

N

LO

W B

AT

BA

T MIS

RE

BA

T

ON B

AT

SI

RTN

12V R

TN

+12VD

C

Fiber
Jumper

Optical
Connection

TELEPHONE TROUBLESHOOTING:
1.  Identify the bad line (POTS 1-8).
2.  Plug any working phone into 
      the appropriate jack.
        If the telephone works, the unit
            is functioning normally.
        If the telephone does not work, 
           contact your service provider.
3.  Remove the telephone from the 
       POTS jack.

TOTAL ACCESS 372

1287722G1

FiberTray

Verify Local Power Source Wiring

The ONT needs to be powered by a UL Listed Power Supply that is 

suitable for the application with Output at Local Power Supply (LPS) 

Levels.

Install the UPS

Installation of the UPS (P/N 1187735G1) will be dictated by on-site condi-

tions and local telephone company practices. 

CAUTION

!

Use caution when routing wires and cables. Avoid severe bending and

routing over sharp edges. Use grommets when possible to avoid wear on

cable insulation.

1. Install the UPS cable that runs from the ONT to the Power/Alarm 

connector of the UPS via the customer provided PVC conduit (or 

method used by your local telephone company practice).

2. Swing the electronics module closed and tighten the security screw 

with the 5/32 Hex tamper proof bit. Do not exceed 20 in lbs of 

torque.

3. If necessary, tie wrap both the #6 ground wire and the UPS cable 

run to the Buried Fiber Drop riser conduit.

NOTE

Refer to the 

Total Access 300 Series Small Business Unit ONT Installation and

Maintenance Guide 

(P/N 612877SBONT-5) for testing and verification

information. 

O

PERATIONAL

 S

PECIFICATIONS

Voltage Range: 12 VDC (nominal) 10.8 VDC to 14.4 VDC (tolerance)

Maximum Current: 2.0 Amp

Dimensions

o

Height: 15.0 inches (38.1 centimeters)

o

Width: 9.75 inches (24.8 centimeters)

o

Depth: 4.0 inches (10.1 centimeters)

Weight: 6 pounds (2.7 kilograms) ONT and NID combined

o

NID Only: 3.75 pounds (1.7 kilograms)

o

Electronics Module: 2.25 pounds (1.25 kilograms)

Operational Temperature: –40°F to 149°F (–40°C to +65°C)

Storage Temperature: –40°F to 185°F (–40°C to +85°C)

Relative Humidity: 95%, noncondensing within enclosure

Optical

o

TX min power: 0.5 dBm

o

TX max power: 5.0 dBm

o

RSSI max sensitivity: -27 dBm

o

RX overload: -8 dBm

o

TX wavelength: 1310 nm typical

o

RX wavelength: 1490 nm typical

S

AFETY

 

AND

 R

EGULATORY

 C

OMPLIANCE

Refer

 

to

 

the

 

appropriate

 

Total

 

Access

 

300

 

Series

 

Safety

 

and

 

Regulatory

 

Compliance

 

Notice

 

(P/N

 

61287722G1

17

 

or

 

61287722G2

17)

 

for

 

detailed

 

safety

 

and

 

regulatory

 

information.

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

 ADTRAN CUSTOMER CARE:

From within the U.S.     1.800.726.8663

From outside the U.S. +1 256.963.8716

PRICING AND AVAILABILITY  1.800.827.0807

Summary of Contents for Total Access 300 Series

Page 1: ...nstream traffic uses 1490 nm while upstream traffic is carried on 1310 nm For RF TV distribution 1550 nm is used for downstream and 1610 nm is used for the upstream RF return path The ONT uses optical diplexers to separate the wavelengths This Job Aid covers the electronics module and housings listed in the following table Refer to the Total Access 300 Series Small Business Unit ONT Installation a...

Page 2: ...g After unpacking the ONT inspect it for damage If damage is noted file a claim with the carrier and then contact ADTRAN For more information refer to the warranty Required Tools and Supplies In addition to standard technician tools you will need the following for this installation Carpenter s level 3 32 screw driver for connecting ONT power 5 32 hex tamper proof bit RJ 45 RJ 11 crimper A telephon...

Page 3: ...r and Alarm Connector Description Pin Out UPS Connector 1 LOW BAT 1 2 BAT MIS 2 3 REP BAT 3 4 ON BAT 4 5 SIG RTN 5 6 12 V RTN 6 7 12 VDC 7 Pin 1 Pin 7 1 2 3 4 5 6 7 UPS Power Connector Power Alarm Connector Low Battery Battery Missing Replace Battery On Battery Signal Return 12V Return 12VDC 2 Strip back the jacket of the subscriber Ethernet cable and connect the 4 pair twisted wires to the RJ 45 ...

Page 4: ...normally If the telephone does not work contact your service provider 3 Remove the telephone from the POTS jack TOTALACCESS 372 1287722G1 FiberTray Verify Local Power Source Wiring The ONT needs to be powered by a UL Listed Power Supply that is suitable for the application with Output at Local Power Supply LPS Levels Install the UPS Installation of the UPS P N 1187735G1 will be dictated by on site...