Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
22
61180105L1-5C
The
text
“***INVALID
CONFIGURATION***”
as
seen
in
will
appear
on
the
screen
if
the
user
selects
provisioning
prohibited
by
the
unit.
Invalid
configurations
include
the
following
combinations:
64
kbps
Secondary
Channel,
64
kbps
Zero
Code
Suppression,
Hardware
A/B
Signaling
at
any
rate
other
than
SW56,
SW56
Error
Correction,
and
SW56
Secondary
Channel.
Figure 12. Provisioning Menu Showing Invalid Configuration
Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss
Unacknowledged Alarms: NONE
Total Reach DDS-DP Provisioning
***INVALID CONFIGURATION***
1. Data Rate 64 kbps
2. Secondary Channel Disabled
3. Error Correction Disabled
4. Zero Code Suppression Disabled
5. Latching Loopback Protected
6. Hardware A/B Signaling Disabled
7. Quality Monitor Disconnect Disabled
8. OCU LBO to customer 0dB
Selection:
‘?’ - System Help Screen