Menu Descriptions
61179641AL1-5C
5-89
External Alarm Severity Menu
External Alarm Severity
\
\External Alarm Severity\
The External Alarm Severity menu (see
) is used to set customized alarm profiles
for each of the three external alarms.
Figure 5-57. External Alarm Severity Menu
The External Alarm Severity menu options are shown in
.
NOTE
The alarm severity levels are user-defined based on the impact to
customer service.
Table 5-57. External Alarm Severity Menu Options
Option
Description
Function
1
Critical
This option is used to designate a critical alarm.
2
Major
This option is used to designate a major alarm.
3
Minor
This option is used to designate a minor alarm.
4
Load Shedding
This option is used to designate a critical alarm to
shutdown ADSL services. When Load shedding is
engaged, power usage in the Total Access 1248 is
reduced.
TID: TA1248 Total Access 1248 MM/DD/YY HH:MM
Unacknowledged Alarms: None
External Alarm Severity
1. Critical
2. Major
3. Minor
4. Load Shedding
Selection :
'?' - System Help Screen