ADTRAN NT1 ACE4 User Manual Download Page 5

61200242L1-1

NT1 ACE

4

User Manual

v

AFFIDAVIT FOR CONNECTION OF CUSTOMER

PREMISES EQUIPMENT TO 1.544 MBPS AND/OR

SUBRATE DIGITAL SERVICES

For the work to be performed in the certified territory of
_______________
(telco name)
State of ___________________
County of _________________
I, ______________________________(name),
________________________________(business address),
______________________ (telephone number) being duly
sworn, state:
I have responsibility for the operation and maintenance of
the terminal equipment to be connected to 1.544 Mbps
and/or ________ subrate digital services. The terminal
equipment to be connected complies with Part 68 of the
FCC rules except for the encoded analog content and bill-
ing protection specifications. With respect to encoded an-
alog content and billing protection:
( ) I attest that all operations associated with the estab-
lishment, maintenance, and adjustment of the digital CPE
with respect to analog content and encoded billing pro-
tection information continuously complies with Part 68 of
the FCC Rules and Regulations.
( ) The digital CPE does not transmit digital signals containing
encoded analog content or billing information which is intended
to be decoded within the telecommunications network.

Summary of Contents for NT1 ACE4

Page 1: ...NT1 ACE4 User Manual 1200242L1 NT1 ACE4 336012VUR01 Power Supply 12 VDC 800 mA 61200242L1 1A September 2000...

Page 2: ...901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2000 ADTRAN Inc All Rights Reserved Printed in U S A...

Page 3: ...ack is specifically designed for wet loca tions 3 Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning 4 Do notuset...

Page 4: ...nalog signals and transmitted on the network The affidavit shall affirm that either no encoded ana log content or billing information is being transmitted or that the output of the device meets Part 6...

Page 5: ...ipment to be connected to 1 544 Mbps and or ________ subrate digital services The terminal equipment to be connected complies with Part 68 of the FCC rules except for the encoded analog content and bi...

Page 6: ...de analog signals or B A training course provided by the customer or au thorized representative using training materials and in structions provided by the manufacturer grantee of the equipment used to...

Page 7: ...____Signature _________________________________Title _________________________________ Date Transcribed and sworn to before me This ________ day of ________ 199___ _________________________________ No...

Page 8: ...pproved by the party responsible for compliance could void the user s authority to op erate the equipment Canadian Standards Association This device must be powered by a CSA approved power supply or a...

Page 9: ...ity to maintain uninter rupted service is given 4 If experiencing difficulty with this equipment please con tact ADTRAN for repair and warranty information The telephone company may require this equip...

Page 10: ...to the local telephone company for leased line facilities 8 The FCC recommends that the AC outlet to which equipment requiring AC power is to be installed is pro vided with an AC surge arrester Servic...

Page 11: ...r le ministre des Communications CANADIAN EQUIPMENT LIMITATIONS Notice The Canadian Industry and Science Canada label identifies certified equipment This certification means that the equipment meets c...

Page 12: ...that the electrical ground connections of the power utility tele phone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in...

Page 13: ...will be free from defects in materials and workmanship ADTRAN also warrants that products will conform to the applicable specifications and drawings for such products as contained in the Product Manua...

Page 14: ...NTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THIS EXCLUSION MAY NOT APPLY TO CUSTOMER In no event will ADTRAN or its s...

Page 15: ...air and Return 3 Connections 4 Powering with the NT1 ACE4 Power Supply 6 Connecting the Terminal Equipment 7 Typical Configuration 7 Troubleshooting 8 Specifications 10 Network Interface U 10 Customer...

Page 16: ...Interface Connectors 1 Figure 1 3 Network Connector RJ 45 4 Figure 1 4 Local Bus Connector RJ 45 5 Figure 1 5 Power Supply Connection 6 Figure 1 6 Typical Configuration 8 Tables Table 1 1 Status Indi...

Page 17: ...the basic rate ISDN network U Figure 1 1 is an illus tration of the NT1 ACE4 Figure 1 1 ADTRAN NT1 ACE4 Figure 1 2 shows the interface connectors Figure 1 2 Interface Connectors The four RJ 45 connect...

Page 18: ...1 1 describes the status of the LEDs located on the front panel of the NT1 ACE4 There is a READY and ERROR indicator for each port of the NT1 ACE4 Table 1 1 Status Indicators If an ERROR indicator is...

Page 19: ...pping container for use in shipping the NT1 ACE4 for repair or for verifica tion of damage during shipment Maintenance The NT1 ACE4 requires no routine maintenance to operate In case of equipment malf...

Page 20: ...andard 100 ohm termina tion Tables 1 2 and 1 3 give the connector pin assignments and Figures 1 3 and 1 4 show the connectors Table 1 2 Network Connector Pin Assignments Figure 1 3 Network Connector R...

Page 21: ...Local Bus Connector RJ 45 Pin Description 1 No connection 2 No connection 3 S T interface Receive Power Source 1 Negative 4 S T interface Transmit Power Source 1 Positive 5 S T interface Transmit Pow...

Page 22: ...wer supply to the NT1 ACE4 at the POWER jack located on the NT1 ACE4 rear panel 2 Plug the power supply into the nearest wall outlet sup plying 120 VAC 60 Hz 3 On the NT1 ACE4 verify that the ERROR in...

Page 23: ...Troubleshooting on page 8 As the ERROR indicators extinguish the READY indica tors should illuminate There may be a slight delay between the appearance of the READY indicators and the TE s abil ity t...

Page 24: ...ists of symptoms and solutions below For further assis tance please contact ADTRAN Technical Support at 888 4ADTRAN Symptom Action ERROR and READY indi cators not illuminated Verify power connection C...

Page 25: ...at a slower 1 Hz rate Local bus failure TE not connected Connect TE TE not receiving power from NT1 Consult TE documentation TE not terminated properly Correct termination READY indicators do not ill...

Page 26: ...e S T Line 4 Wire Tx and Rx Pair Operating Mode Full Duplex Data Rate 192 kbps total 144 kbps to customer Signal Format Alternate Mark Inversion 100 duty cycle Output Amplitude 0 75 volt zero to peak...

Page 27: ...ounting Wall or desktop Power 12 VDC 3 3 W dissipation Environment Temperature 0 to 50 C 32 to 104 F operating 20 to 70 C 4 to 158 F storage Relative Humidity Up to 95 non condensing Power Supply Spec...

Page 28: ...NT1 ACE4 User Manual 12 NT1 ACE4 User Manual 61200242L1 1...

Page 29: ...cal Support 888 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed Technical Support will coordinate with the Customer and Product Service CAPS department to issu...

Page 30: ......