background image

617101568F1-13A

7

Resetting the Switch 

By pressing the 

RESET

 button for certain period of time, you can perform the following tasks:

■ Reset the switch (to reboot and restore the switch to the previous configuration settings saved) 
■ Restore the switch to factory defaults (to restore the original factory default settings to the switch)

Troubleshooting the Switch

The following table provides information to easily troubleshoot problems by taking actions based on the suggested solutions.

Product Specifications

Compliance

■  This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

■ 1. This device may not cause harmful interference.
■ 2. This device must accept any interference received, including interference that may cause undesired operation.

■ Changes or modifications not expressly approved by ADTRAN could void the user's authority to operate this equipment.
■ Changes or modifications not expressly approved by ADTRAN will void the warranty.
■ This equipment contains no parts that can be serviced by the user.

■ This product is NRTL Listed to the applicable UL/CSA Standards. This product has also been evaluated to applicable international standards for CE 

marking and RCM marking.

■ This product meets EU RoHS Directive. Refer to 

www.adtran.com/environmental 

for further information on RoHS/WEEE.

NOTE

g

As seen in the table below, you can easily judge which task is being performed by reading the LED behaviors while pressing and holding the 

RESET

 

button. 

Once the correct LED behaviors are displayed, release the button

.

Task

Press for...

System LED Behavior

Port Status LED Behavior

Reset the Switch

2 ~ 7 seconds

Flashing Green

All LEDs are OFF.

Restore to Factory Defaults

7 ~ 12 seconds

Flashing Green

All LEDs are ON.

Symptoms

Possible Causes

Suggested Solutions

System LED is OFF

The switch is not receiving 

power.

1. Check if correct power cord is connected firmly to the switch and to the AC outlet socket.
2. Cycle the power on the switch by unplugging and plugging the power cord back into the 

switch.

3. If the LED is still off, try plugging the power cord into different AC outlet. 

System LED is RED

An abnormal state has been 

detected by the switch.

Check the system log within the switch from web user interface to understand the abnormal state 

(e.g., exceeding operating temperature range) and take corresponding actions to resolve.

Port Status LED is OFF

The port is not connected or 

the connection is not function

-

ing.

1. Check if the cable connector plug is firmly inserted and locked into the port at both the switch 

and the connected device.

2. Make sure the connected device is up and running correctly.
3. If the symptom still exists, try using a different cable or different port, in order to identify if it is 

related to the cable or specific port. 

4. Check if the port is disabled in the configuration settings via web user interface. 

NOTE

g

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 

cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his own expense. CAN ICES-003 (A)/NMB-003(A)

Summary of Contents for NetVanta 1560-48

Page 1: ...ipment NetVanta 1560 48 SYSTEM CONSOLE USB RESET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 51 52 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 RESET Button Port Status LEDs SYS LED CONSOLE Port 10 100 1000 2500 RJ 45 1G 2 5G 10G SFP Ports AC Line 100 240V 50 60Hz AC Line 100 240V 50 60Hz Power Connection f WARNING f CAUTION g NOTE WARNING indica...

Page 2: ...ewdriver to secure the brackets Figure 3 Attaching Brackets to the Switch 2 Position the chassis in the stationary equipment rack Allow 1 inch of clearance between units NOTE g Refer to the national state and local electrical codes for the requirements for power grounding wiring and installation methods CAUTION f The NetVanta 1560 48 is intended for indoor use only Ethernet PoE cables and attached...

Page 3: ... Supplying Power to the Switch To connect the AC power cord to the switch complete the following steps 1 Connect the AC power cord to the AC power receptacle on the rear panel of the switch 2 Connect the other end of the AC power cord to a properly grounded AC power outlet The AC branch circuit socket outlet must be installed near the equipment and must be easily accessible NOTE g Rack mount brack...

Page 4: ...nal state and local electrical code requirements as applicable The AC branch circuit overcurrent protection must be a fuse or circuit breaker rated 125 VAC 20 Amps maximum or 250 VAC 16 Amps maximum A readily accessible disconnect device that is suitably approved and rated must be incorporated in the field wiring CAUTION f It is recommended that an external AC Surge Protection Device be installed ...

Page 5: ...e g 255 255 255 0 g Select OK to change the PC s IP address 3 Power up the switch to be initially configured and wait until it has finished its start up processes 4 Connect the PC to any port on the switch using a standard Ethernet cable and check the port LED on the switch to make sure the link status of the PC is OK 5 Run your web browser on the PC enter either the DHCP assigned or factory defau...

Page 6: ...m has been triggered for troubleshooting Port Status LEDs The Port Status LEDs indicate the current status of each port NOTE g The factory default username of the switch is admin The factory default password is password NOTE g There are many terminal emulation applications available on the web PuTTY SecureCRT and HyperTerminal are a few examples LED Color State Description SYSTEM Off The switch is...

Page 7: ...store to Factory Defaults 7 12 seconds Flashing Green All LEDs are ON Symptoms Possible Causes Suggested Solutions System LED is OFF The switch is not receiving power 1 Check if correct power cord is connected firmly to the switch and to the AC outlet socket 2 Cycle the power on the switch by unplugging and plugging the power cord back into the switch 3 If the LED is still off try plugging the pow...

Page 8: ...ng or maintaining always place devices on an approved antistatic mat that is electrically grounded Warranty ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can be found online at www adtran com warranty Trademarks Brand names and product names included in this document are trademar...