ADTRAN NetVanta 1560-48-740W Quick Start Manual Download Page 5

617108148PF2-13D

5

Right-click on your 

local adapter

 and select 

Properties

.

In the 

Local Area Connection Properties

 menu, highlight 

Internet Protocol Version 4 (TCP/IPv4)

. Then, select the 

Properties

 

button.

g

     NOTE

Be sure to record all your PC’s current IP settings to be able to restore them later.

Select the radio button 

Use the following IP address

 and enter in the IP address for the PC (e.g., any IP address not in use, 

and in between 10.10.10.2 and 10.10.10.254), subnet mask (e.g., 255.255.255.0).

 

Select 

OK

 to change the PC’s IP address.

3. Power up the switch to be initially configured, and wait until it has finished its start-up processes.
4. Connect the PC to any port on the switch using a standard Ethernet cable, and check the port LED on the switch to make sure the 

link status of the PC is OK.

5. Run your web browser on the PC; enter either the DHCP-assigned or factory default IP address to access the switch’s web 

interface. If your PC is configured correctly, you will see the login page of the switch requesting your username and password. In 

some browsers, the information needed may be requested in a new window. 

If you do not see the login page, perform the following steps: 

a. Refresh the web page.
b. Check to see if there is an IP conflict issue. 
c. Clean browser cookies and temporary Internet files. 
d. Check your PC settings again and repeat Step 2.

6. Enter the factory default username in the login page. Select 

Login

 to log into the switch. 

g

     NOTE

The factory default username of the switch is 

admin

. The factory default password is 

password

.

Initial Switch Configuration Using CLI

The CLI can be accessed using any one of the two console ports (USB & RJ45) available in the switch. To establish the connection to the 

console port, the following are needed:

PC with VT100 terminal emulation software

Micro USB to USB cable or a DB-9 to RJ45 Serial Cable (the cables are provided along with the unit)

g

     NOTE

There are many terminal emulation applications available on the web. PuTTY, SecureCRT, and HyperTerminal are a few examples.

Complete the following steps:

1. Connect a Micro USB cable to the micro USB CONSOLE port or connect a DB-9 to RJ-45 serial cable to the RJ-45 CONSOLE port.
2. If using a Micro USB cable, connect the other end of the USB cable to a USB port on the PC. If using an RJ-45 serial cable, connect 

the other end to the serial terminal on the PC.

3. If using the Micro USB cable to connect the switch, check if the USB drivers are automatically installed in the PC. If not install 

manually.

4. Open a VT100 terminal session using the following settings: 115200 baud; 8 data bits; no parity bits; 1 stop bit; and no flow control. 

Press <Enter> to activate the CLI.

5. Login with the default user name (

admin

) and password (

password

).

Power Over Ethernet (PoE)

The switch provides the PoE on the 48 Ethernet ports shown in 

Figure 1

. PoE provides the ability to detect attached Powered Devices 

(PDs), and deliver power to the PD via Ethernet cabling. The switch is fully compliant with the IEEE 802.3af PoE and IEEE 802.3at PoE+ 

standards. By default, the PoE switch discovers and provides power to IEEE-compliant PDs, it also supports legacy PDs.

 

The total PoE budget for the switch is 740W. Each port can provide a maximum of 30W in compliance to the IEEE 802.3at PoE+ 

standard. All 48 ports cannot have 30W PD devices as this exceeds the PoE budget of the switch; a combination of few 30W PDs and 

low power PDs can be used as long as the sum of load is less than 740W.

Summary of Contents for NetVanta 1560-48-740W

Page 1: ...art f WARNING The NetVanta 1560 48 740W is intended for indoor use only Ethernet PoE cables and attached equipment are intended for use within the same building with equipotential bonding and not inte...

Page 2: ...g steps 1 Attach the mounting brackets to both sides of the chassis Insert the provided screws and tighten them with a screwdriver to secure the brackets Figure 3 Attaching Brackets to the Switch 2 Pl...

Page 3: ...top and sides of the unit for sufficient air flow Connect AC Power To connect the AC power cord to the switch complete the following steps 1 Connect the AC power cord to the AC power receptacle on th...

Page 4: ...face of the switch using the switch s default IP address as shown below g NOTE The factory default IP address of the switch is 10 10 10 1 and the subnet mask is 255 255 255 0 If the switch is connecte...

Page 5: ...the two console ports USB RJ45 available in the switch To establish the connection to the console port the following are needed PC with VT100 terminal emulation software Micro USB to USB cable or a DB...

Page 6: ...LED On The port status LEDs are displaying link status network activity and the speed of each port LED Color State Description PoE On The RJ 45 port status LEDs are displaying the PoE powering status...

Page 7: ...faults 7 12 seconds Flashing Green All LEDs are ON Symptoms Possible Causes Suggested Solutions System LED is OFF The switch is not receiving power 1 Check if correct power cord is connected firmly to...

Page 8: ...0 C to 45 C Storage Temperature 40 F to 158 F 40 C to 70 C Relative Humidity 10 to 95 percent non condensing Electrical Power Supply 100 to 240 VAC 50 60 Hz 11A Documentation for ADTRAN Network Solut...

Reviews: