ADTRAN NetVanta 1560-08-65W Quick Start Manual Download Page 3

617101561PF2-13A

3

Mounting on a Desk or Shelf

To mount the switch on a desk or shelf, complete the following steps.

1. Verify that the desk or shelf is sturdy enough to support the switch. 

2. Attach the four adhesive rubber feet to the bottom of the switch.

Figure 5. Attaching the Rubber Feet

f

     

CAUTION!

Desk, shelf, or wall mounting of the equipment should be such that the amount of air flow required for safe operation of the equipment is not compromised. Allow 1-inch 

clearance on the top and sides of the unit for sufficient air flow.

Mounting on a Wall

To mount the switch on a wall, complete the following steps.

1. Using the mounting holes on the bottom of the unit as a template, install two #6 PAN head screws (0.75-inch) in the appropriate location on the wall. Be aware of the 

dimensional limitations of the screws.

Figure 6. Install Screws in the Wall

2. Slide the keyed insets on the bottom of the unit’s chassis securely onto the screws.

Figure 7. Attaching the Switch to the Wall

f

     

CAUTION!

The NetVanta 1560-08-65W must be mounted in the face down orientation when wall mounted.

Summary of Contents for NetVanta 1560-08-65W

Page 1: ...cal electrical codes for the requirements for power grounding wiring and installation methods f WARNING Read all warnings cautions notes and installation instructions before installing or servicing th...

Page 2: ...5W switch complete the following steps Mount The Switch The switch can be mounted in a 19 inch rack on a desk or shelf or on a wall Mounting in a 19 inch Rack g NOTE Mounting brackets are not included...

Page 3: ...ot compromised Allow 1 inch clearance on the top and sides of the unit for sufficient air flow Mounting on a Wall To mount the switch on a wall complete the following steps 1 Using the mounting holes...

Page 4: ...local AC Powered product The Surge Protection device should provide L N L G and N G protection It is also recommended that the device contains a visual GOOD indicator f WARNING This equipment incorpor...

Page 5: ...following IP address and enter in the IP address for the PC e g any IP address not in use and in between 10 10 10 2 and 10 10 10 254 subnet mask e g 255 255 255 0 Select OK to change the PC s IP addr...

Page 6: ...PD Mode LED Is Lit When the LINK ACT SPD Mode LED is lit the link act spd status is indicated by the LED behavior LED Color State Description SYSTEM Off The switch is not receiving power On The switch...

Page 7: ...n disabled through the switch user interface Task Press for System LED Behavior Port Status LED Behavior Change LED Mode 0 2 seconds Solid Green LED status will change according to the mode selected R...

Page 8: ...gned to function without degradation during the exposure to all test severities per 3 1of ETSI EN 300 019 1 3 Electrical Power Supply 100 to 240 VAC 50 60 Hz 2A f CAUTION Electrostatic Discharge ESD c...

Reviews: