1.
Securely fasten the mounting brackets to the NetVanta 1110 RPS using the screws provided
with the unit.
Important!
To avoid damaging the unit when attaching the mounting brackets, use only the
screws supplied with the unit.
2.
To allow proper grounding, scrape the paint from the rack around the mounting holes where
the RPS will be positioned.
3.
Position the RPS in a stationary equipment rack either above or below the NetVanta 1238
PoE (see
4.
Have an assistant hold the RPS in position as you install two appropriate mounting bolts
through the unit’s brackets and into the equipment rack.
5.
Connect the NetVanta 1110 RPS to the NetVanta 1238 PoE following the steps in
Connecting the RPS and the NetVanta 1238 PoE
Figure 1. Rack Mounting the RPS
T
ABLETOP
I
NSTALLATION
OF
THE
RPS
1.
Before installing the RPS on a horizontal surface, attach the rubber foot pads (included with
the unit) to the bottom of each corner of the unit. The rubber feet cushion the unit, protect the
casing from scratches and prevent it from scratching other surfaces.
2.
Locate a sturdy, level tabletop or shelf that can support at least 30 pounds.
3.
Place the RPS on the tabletop or shelf to the right of the NetVanta 1238 PoE with 2 inches of
space between the units.
Important!
For adequate ventilation, the RPS should only mounted to the right of the
NetVanta 1238 PoE and 2 inches of space should be maintained between the units and
other objects in the vicinity. Do not place the units on top of each other or block ventilation
openings.
4.
Proceed to the steps given in
Connecting the RPS and the NetVanta 1238 PoE.
G2
G3
G4
NetVanta 1238
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
1
3
5
9
11
13
15
2
4
6
8
10
12
14
16
17
19
21
23
25
27
29
31
18
20
22
24
26
28
30
32
33
35
37
39
41
43
45
47
34
36
38
40
42
44
46
48
STAT
G1
G1
G2
G3
G4
LINK/ACT
PoE
Power over Ethernet
®
NetVanta 1110 RPS
POWER
Redundant Power Supply
C
ONNECTING
THE
RPS
AND
THE
N
ET
V
ANTA
1238 P
O
E
1.
With a Phillips head screwdriver, remove the cover plates from both the NetVanta 1110
RPS and the NetVanta 1238 PoE’s RPS receptacles on the rear panels of the units.
2.
Compare the
TOP
surfaces of the connectors on either end of the RPS cable. On one
connector, the right edge of the tab covering the pins is flush with the pins, while on the
other connector, the tab is offset to the right of the pins approximately 0.16 inch (see
Figure 2. RPS Connectors
3.
With the
TOP
surface of the connector with the offset tab facing upward, insert it into the
receptacle labeled
RPS OUTPUT
located on the rear panel of the NetVanta 1110 RPS see
). Press the connector until the pins are fully inserted and the base of the connector
is flush with the unit.
Important!
Do not use excessive force. If the connector does not insert easily, check to
ensure you are inserting the correct connector into the unit.
4.
Tighten the thumb screws located on either side of the connector.
5.
With the
TOP
surface facing upward, insert the other RPS connector (with the flush tab)
into the receptacle labeled
RPS
located on the rear panel of the NetVanta 1238 PoE (see
). Press the connector until the pins are fully inserted and the base of the connector
is flush with the unit.
6.
Tighten the thumb screws located on either side of the connector.
7.
Powering the RPS and the NetVanta 1238 PoE
.