NetVanta 1000 Series Switch Hardware Installation Guide
Option Modules
61200500L1-34C
© 2004 ADTRAN, Inc.
27
NetVanta T1/FT1 NIM (P/N 1200862L1 and 61202862L1)
The T1/FT1 NIM (shown in Figure 8) provides a T1 WAN interface for the NetVanta. This provides a full
T1 or fractional T1 network interface. Refer to Table A-6 on page 43 for the WAN-T1 connector pinout,
and Table A-11 on page 46 for the DBU connector pinout. An optional DIM is required for dial backup
applications.
Figure 8. NetVanta T1/FT1 NIM
WAN-T1
DBU
Features and Specifications
Operating Modes
•
T1/FT1 Frame Relay
•
T1/FT1 PPP
T1/FT1 Interface
•
Line Rate: 1.544 Mbps +/- 75 bps
•
Line Code: AMI or B8ZS
•
Framing: D4 (SF) or ESF
•
FT1 Line Rate: DS0 Channelized
(multiples of 56/64 kbps)
•
Input Signal: 0 to -36 dB (DS-1)
•
Line Build-Out: 0, -7.5, -15, -22.5 dB
•
Connector: RJ-48C
•
DS0 Assignment: Programmable
Clock Source
•
Network
•
Internal
Diagnostics
•
Test pattern generation and detection:
QRSS and 511
•
Network loopbacks (local and remote);
responds to both INBAND and FDL loop
codes
•
Alarm generation and detection
•
Network and user sets of performance data
(15 minute and 24 hour)
Relevant Requirements/Standards
•
EMC - see
(EMC) Table for the NetVanta
1224STR/1224R
•
ACTA/FCC Part 68
•
Industry Canada CS03
•
UL and CUL
•
T1 Interface: Pub 62411
•
ESF Format Interface: TR. 194
•
ESF Performance Monitoring: TR. 54016
and T1.403
Environmental
•
Operating Temperature: 0 °C to 50 °C
•
Storage Temperature: -40 °C to 85 °C
•
Relative Humidity: Up to 95%
noncondensing
Physical
•
Dimensions: 4.25" x 2.75"