2
61287565G1-22B
3. Refer to the following illustration and insert the RJ-11
connector in the POTS port.
Step 3: Connect Ethernet
The Small Form Factor ONT supports a Gigabit (10/100/
1000Base-T) connection (ETH).
If an Ethernet cable is not available, use the following procedure
and table to create the Ethernet cable:
1. Use a CAT 6 rated cable and trim the insulation for the sub-
scriber Ethernet cable back approximately 1/2 inch.
2. Connect the wires per the following table using an RJ-45
Crimper.
3. Refer to the illustration at the top of the next page and insert
the CAT 6 rated cable in the ETH Port.
Ethernet RJ-45 Pin-out
Pin
Name
Description
Color Code
1
TRD0+
Transmit/Receive Positive
White/Orange
2
TRD0-
Transmit/Receive Negative
Orange
3
TRD1+
Transmit/Receive Positive
White/Green
4
TRD2+
Transmit/Receive Positive
Blue
5
TRD2-
Transmit/Receive Negative
White/Blue
6
TRD1-
Transmit/Receive Negative
Green
7
TRD3+
Transmit/Receive Positive
White/Brown
8
TRD3-
Transmit/Receive Negative
Brown
1 2 3 4
1 = Not Connected
2 = Tip
3 = Ring
4 = Not connected
POTS Pin-Outs
POTS
Port
Required tools
Standard technician tools and those listed below are required for
installing the Small Form Factor ONT:
PON power meter with wavelength filtering
Fiberscope or videoscope
Two #8 Pan Head screws (1 inch or greater in length)
Assorted tie wraps for securing cabling and wiring
For fiber optic connections, the following are required:
Fiber optical fusion splice tools
ODC Fiber cleaning tool
SC/APC Fiber connector
Installation Steps
To install the Small Form Factor ONT, refer to the illustrations
and complete the following steps.
Step 1: Install the Small Form Factor ONT
There are two options when installing the Small Form Factor
ONT: Desk Top and Wall Mount. Both are described below.
Desk Top Installation
The Small Form Factor ONT can rest on a desktop or be wall
mounted. With either a wall or desk mount, ensure the Small
Form Factor ONT is not located in direct sunlight and is not
located next to any thermal obstructions.
Wall Mount Installation
To wall mount the Small Form Factor ONT, complete the
following steps:
1. Decide on a location for the Small Form Factor ONT.
2. Attach to drywall using the appropriate anchors.
3. Use the keyhole slots on the back of the Small Form Factor
ONT as a template and install two #8 Pan Head screws (1
inch or greater in length) using the key holes on the back of
the Small Form Factor ONT as location markers. Leave
approximately 1/4 inch protruding from the mounting
surface.
4. Slide the Small Form Factor ONT over the Pan Head screws
and exert a small amount of downward pressure to ensure
that the top of the slots are resting on the shafts of the Pan
Head screws.
Step 2: Connect POTS
To connects POTS to the Small Form Factor ONT, refer to the
illustration at the top of the next column and complete the
following steps.
1. If a POTS cable is not available, trim the insulation for the
POTS cables back approximately 1/2 inch.
2. Connect the twisted-pair Tip (green) and Ring (Red) to the
RJ-11 connector using an RJ-11 crimper.