background image

2

61287565G1-22B

3. Refer to the following illustration and insert the RJ-11 

connector in the POTS port.

Step 3: Connect Ethernet 

The Small Form Factor ONT supports a Gigabit (10/100/
1000Base-T) connection (ETH). 
If an Ethernet cable is not available, use the following procedure 
and table to create the Ethernet cable:

1. Use a CAT 6 rated cable and trim the insulation for the sub-

scriber Ethernet cable back approximately 1/2 inch.

2. Connect the wires per the following table using an RJ-45 

Crimper.

3. Refer to the illustration at the top of the next page and insert 

the CAT 6 rated cable in the ETH Port.

Ethernet RJ-45 Pin-out

Pin

Name

Description

Color Code

1

TRD0+

Transmit/Receive Positive

White/Orange

2

TRD0-

Transmit/Receive Negative

Orange

3

TRD1+

Transmit/Receive Positive

White/Green

4

TRD2+

Transmit/Receive Positive

Blue

5

TRD2-

Transmit/Receive Negative

White/Blue

6

TRD1-

Transmit/Receive Negative

Green

7

TRD3+

Transmit/Receive Positive

White/Brown

8

TRD3-

Transmit/Receive Negative

Brown

1 2 3 4

1 = Not Connected
2 = Tip
3 = Ring
4 = Not connected

POTS Pin-Outs

POTS
Port

Required tools

Standard technician tools and those listed below are required for 
installing the Small Form Factor ONT:

PON power meter with wavelength filtering

Fiberscope or videoscope

Two #8 Pan Head screws (1 inch or greater in length)

Assorted tie wraps for securing cabling and wiring

For fiber optic connections, the following are required:

Fiber optical fusion splice tools

ODC Fiber cleaning tool

SC/APC Fiber connector

Installation Steps

To install the Small Form Factor ONT, refer to the illustrations 
and complete the following steps.

Step 1: Install the Small Form Factor ONT

There are two options when installing the Small Form Factor 
ONT: Desk Top and Wall Mount. Both are described below.

Desk Top Installation

The Small Form Factor ONT can rest on a desktop or be wall 
mounted. With either a wall or desk mount, ensure the Small 
Form Factor ONT is not located in direct sunlight and is not 
located next to any thermal obstructions. 

Wall Mount Installation

To wall mount the Small Form Factor ONT, complete the 
following steps:

1. Decide on a location for the Small Form Factor ONT. 
2. Attach to drywall using the appropriate anchors.
3. Use the keyhole slots on the back of the Small Form Factor 

ONT as a template and install two #8 Pan Head screws (1 
inch or greater in length) using the key holes on the back of 
the Small Form Factor ONT as location markers. Leave 
approximately 1/4 inch protruding from the mounting 
surface.

4. Slide the Small Form Factor ONT over the Pan Head screws 

and exert a small amount of downward pressure to ensure 
that the top of the slots are resting on the shafts of the Pan 
Head screws.

Step 2: Connect POTS

To connects POTS to the Small Form Factor ONT, refer to the 
illustration at the top of the next column and complete the 
following steps.

1. If a POTS cable is not available, trim the insulation for the 

POTS cables back approximately 1/2 inch.

2. Connect the twisted-pair Tip (green) and Ring (Red) to the 

RJ-11 connector using an RJ-11 crimper.

Reviews: