background image

PRICING AND AVAILABILITY   800.827.0807

TECHNICAL SUPPORT   800.923.8726

RETURN FOR REPAIR   256.963.8722

www.adtran.com

61246041L1-22A

T200 HRE TURN-UP GUIDE

LOOP BACK

LOOP THRU

SHORT

OPEN

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49                

CUST

NET

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

LOOP 1

LOOP 2

P7

P5

T

NET

CUST

P13

P15

R

T

R

LOOP
BACK
LOOP
THRU

SHORT

OPEN

SW1

P41

P55

T

NET

CUST

P47

P49

R

T

R

P17

P1/P11

FRM
GND

-48
RET

P35

-48V

1996

5244.065-1D

c

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

INSERTING THE TAC

For test access using the TAC, insert the TAC into the repeater housing as follows.

Hold card with the index finger through the finger hole viewing the edge of the card
so that SW1 is facing to the right. The edge of the card being viewed corresponds to
the faceplate of the HRE. Insert card into the slot with the same orientation as the
T200 HRE. Test Access Card (TAC), part number 1244065L1, or Test Access Module
(TAM), part number 1245065L1, can be used for testing the slot.

TESTING THE CO PAIRS

LOOPBACK

1.

To loopback the circuit put SW1 in the LOOPBACK position. This loops the circuit

back to the CO and to the field.

LOOPTHRU

2.

To loopthru the CO pairs to the field pairs put SW1 in the LOOPTHRU position.

This bridges the circuit pairs.

SHORT

3.

To short the CO pairs put SW1 in the SHORT position. This connects transmit to

receive on each loop.

OPEN

4.

To open the circuit put SW1 in the OPEN position. This allows for a voltage 

measurement across pairs.

AVAILABLE ACCESS

Label

Description

P7

LOOP1 Transmit towards NET

P13

LOOP 1 Receive towards CUST

P5

LOOP 1 Transmit towards CUST

P15

LOOP 1 Receive towards CUST

P41

LOOP 2 Transmit towards NET

P47

LOOP 2 Receive towards NET

P55

LOOP 2 Transmit towards CUST

P49

LOOP 2 Receive towards CUST

P17

–48RET

P1

Frame Ground

P11

Frame Ground

P35

–48 volts

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s
order for use in the U.S. is ten (10) years.  For a complete faxback copy of ADTRAN’s 

U.S. and

Canada Carrier Networks Equipment Warranty

: (877) 457-5007, Document 414.

COMPLIANCE

This product complies with UL 1950, third edition.  It is 
intended for installation in restricted access locations only and
in equipment with a Type “B”’ or “E” installation code.  Ensure
chassis ground is properly connected.

Code

Input Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

X

Installation Code (IC)

A

Reviews: