HDSL 3192 HTU-C Installation and Maintenance Practice
22
61247004L1-5A
Current System Status - HRE Screen
From the Current System Status screen, press
H
once to view current system status for
HRE#1. Press “
H
” a second time to view current system status for HRE#2. See
for the
HRE Current System Status screen.
Figure 9. Current System Status - HRE Screen
Circuit ID:HNTSVLALHDSL MM/DD/YY hh:mm:ss
LOOP #1 <NETWORK> LOOP #2 CURRENT SYSTEM STATUS LOOP #1 <CUSTOMER>LOOP #2
-------- HRE #1 --------- --------- HRE #1 --------
27(27) dB 28(28) dB <- LOSS CUR(MAX) -> 29(29) dB 29(29) dB
YES YES <- SYNC -> YES YES
000/00000 000/00000 <- ES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <- SES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <- UAS 15M/24H -> 000/00000 000/00000
LOOPBACK INACTIVE LOOPBACK INACTIVE
HRE#1 NET SIGNAL QUALITY N = NETWORK SIDE RECEIVER HRE#1 CUST SIGNAL QUALITY
HRE#1 NET SIGNAL QUALITY N = NETWORK SIDE RECEIVER HRE#1 CUST SIGNAL QUALITY
C = CUSTOMERSIDERECEIVER
HTU-C MARGIN (dB) HTU-R MARGIN (dB)
CUR/MIN/MAX ____ LP1 ____ LP1 ____ ____ CUR/MIN/MAX
LP1 00/00/00 |HTUC| |HRE1| |HRE2| |HTUR| LP1 00/00/00
LP2 00/00/00 | |===N| |C===| |====| | LP2 00/00/00
| | | | | | | |
| |===N| |C===| |====| |
|____| |____| |____| |____|
LP2 LP2
Press “Z” to zero registers, “X” to restart MIN/MAX, “M” for Main Menu
“P” for previous view, “H” for HDSL Range Extender #2 (HRE) view.