Connections
61247004L1-5A
11
CONNECTIONS
The 3192 HTU-C occupies one card slot in a CI Wescom 3192 Office Repeater Bay. Power and
alarm signals are provided to the card through the backplane of the shelf. DSX-1 and HDSL loop
signals are connected to the wire-wrap pins or mass termination shelf connectors corresponding
to the slot the unit occupies. Connections to the DSX pins are intended for intra-building wiring
only. Refer to
for 3192 HTU-C edge connector wiring.
The 3192 HTU-C is capable of span powering the HTU-R by applying simplex current to the
local loop. From 10 to 125 mA of current is coupled onto the HDSL span to power the HTU-R
and HRE when deployed.
Figure 3. 3192 HTU-C Edge Connector Wiring
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E
F
H
J
K
L
R TX DSX (In from DSX)
R1 RX DSX (Out to DSX)
–48 VDC Return
R1 HDSL Loop 2
–48 V
R HDSL Loop 1
Fuse Alarm (to Alarm Module)
T TX DSX (In from DSX)
T1 RX DSX ( Out to DSX)
T1 HDSL Loop 2
RCV LOS (to Alarm Module)
Frame Ground
T HDSL Loop 1
HDSL Loops 1 and 2 are
dual duplex loops (capable
of transmitting and receiving
data simultaneously).