background image

2

Section 61242.047L2-13, Issue 1

61242.047L2-13A

0

12

11

10

9

8

7

6

5

4

3

2

1

0

1

2

3

4

WORKING LENGTH OF 26 GAUGE CABLE (KFT)

WORKING LENGTH OF 24 GAUGE (OR COARSER) CABLE (KFT)

5

6

7

8

9

2.5

INVALID HDSL CABLE LENGTHS

2.0

1.5

1.0

0.5

0.0

TOTAL

BRIDGED

TAP

LENGTH

(KFT)

VALID HDSL CABLE LENGTHS

ADTRAN Customer Service:

ADTRAN Telco Technical Support ............... (800) 726-8663
Standard support hours ................................ Monday-Friday

7 a.m. - 7 p.m. CST

Emergency support ................... 7 days/week, 24 hours/day

Sales ............................................................. (800) 827-0807

RMA (repair service) ....................................  (205) 963-8722

Repair and Return Address:
ADTRAN, Inc.
Customer Service Department
901 Explorer Boulevard
Huntsville, Alabama  35806-2807

These approximations are to be used as guidelines
only and may vary slightly on different loops.  Adhering
to these guidelines should produce performance in
excess of 10

-7 

BER.

Frequency (Hz)

Maximum Loss (dB)

3,000

12.0

10,000

15.0

50,000

25.5

100,000

30.0

150,000

32.75

200,000

35.25

Loop Insertion Loss Data

Cable

Cable

Temperature:

Gauge

Type

68

°

90

°

120

°

26

PIC

3.902

4.051

4.253

26

Pulp

4.030

4.179

4.381

24

PIC

2.863

2.957

3.083

24

Pulp

3.159

3.257

3.391

22

PIC

2.198

2.255

2.333

22

Pulp

2.483

2.45

2.629

19

PIC

1.551

1.587

1.634

19

Pulp

1.817

1.856

1.909

HDSL Loss Values

(200 kHz cable loss in dB/kft at 135

)

Channel Bank

 

Backplane

Central Office

Customer Premises

2B1Q

12 kft 24-AWG

9 kft 26-AWG

(max.)

Loop 1

Loop 1

5

6

3

4

FT1-DP

FT1-Repeater

DS1

7

13

5

15

FNID

55

49

2B1Q

12 kft 24-AWG

9 kft 26-AWG

(max.)

Reviews: