Cross-Connect Map

The purpose of the cross-connect map is to allocate
the time slots (TS0s) from the SHDSL loop to user
ports (E1, V.35/X.21) and configure framing.  The
cross-connect maps can be accessed via the VT100
terminal screens.  Select “1,” 

Provisioning

, from the

Main Menu.  Choose to provision the local unit
(Selection 1) or the remote unit (Selection 2).  Next,
select “1,” 

Unit Options

, and then “3,” 

Cross Connect

Map

.  The cross-connect map is shown in 

Figure 6

.

The cross-connect map is split down the middle in two
sections.  The left section of the map lists the SHDSL
time slots and right section of the map lists the G.703
time slots.  The user builds a new pending map before
making it active with the apply key.  The options
listed at the bottom of the screen allow the user to
setup and manipulate the time slots.  The statement
under the list of commands indicates the framing
status.  Time slot configuration options are defined as
follows:

0. Idle

If a time slot is set for idle, an idle code is inserted.
The pattern will always be FF hex (all 1s) toward the
SHDSL network.

The idle pattern out the G.703 interface is
programmable under the G.703 option. The default is
value FF hex (all 1’s).

1. - 31.  G.703 Service

The selected time slot will carry G.703 service (Refer
to the

 Full G.703 Services 

subsection for more

information).

32. G.704 Framing

This option enables three different framing
configurations.  Framing is always set in the first time
slot (TS0).  The framing will be locally generated if
32 is entered in the G.703 TS0 slot only.  If 32 is
entered in the G.703 TS0 and the SHDSL TS0, then
the framing will be passed transparently between the
G.703 and SHDSL ports.  If values other than 32 are
assigned to both the SHDSL TS0 slot and G.703 TS0
slot then the operation is G.703 unframed (if other
G.703 service values are assigned to the G.703 time
slots).

33.  Nx64k Service

The selected time slot will carry Nx64k service.  The
value assignment is only valid for the SHDSL time
slots.

A.  Apply New Map

This command saves and activates any changes made
by the user.

U.  Undo New Map

This command will undo any changes made by the
user since the last saved configuration.  The new
pending map will revert to the currently active time
slot assignments.

Circuit ID:                                                   01-Jan-00 22:03:22
Unit Mode:  NT             Provisioning Type: Local

                               Cross-Connect Map
             SHDSL Timeslots                        G.703 Timeslots
    TS0  = 32   TS12 = 1    TS24 = 1       TS0  = 32   TS12 = 1    TS24 = 1
    TS1  = 1    TS13 = 1    TS25 = 1       TS1  = 1    TS13 = 1    TS25 = 1
    TS2  = 1    TS14 = 1    TS26 = 1       TS2  = 1    TS14 = 1    TS26 = 1
    TS3  = 1    TS15 = 1    TS27 = 1       TS3  = 1    TS15 = 1    TS27 = 1
    TS4  = 1    TS16 = 1    TS28 = 1       TS4  = 1    TS16 = 1    TS28 = 1
    TS5  = 1    TS17 = 1    TS29 = 1       TS5  = 1    TS17 = 1    TS29 = 1
    TS6  = 1    TS18 = 1    TS30 = 1       TS6  = 1    TS18 = 1    TS30 = 1
    TS7  = 1    TS19 = 1    TS31 = 1       TS7  = 1    TS19 = 1    TS31 = 1
    TS8  = 1    TS20 = 1    TS32 = N/A     TS8  = 1    TS20 = 1
    TS9  = 1    TS21 = 1    TS33 = N/A     TS9  = 1    TS21 = 1
    TS10 = 1    TS22 = 1    TS34 = N/A     TS10 = 1    TS22 = 1
    TS11 = 1    TS23 = 1    TS35 = N/A     TS11 = 1    TS23 = 1
       Timeslot Assignments                         Commands
        0.  Idle                   A.  Apply New Map   G.  Full G.703 Service
    1.-31.  G.703 Service 1-31     U.  Undo New Map    N.  Full Nx64K Service
       32.  G.704 Frame              Tab.  Select SHDSL or G.703 Timeslots
       33.  Nx64K Service                  Arrow Keys.  Move Cursor
                           G.704 Framing = LT Delivered

Figure 6.  Cross-Connect Map

Summary of Contents for Express 6530 SHDSL NxNTU

Page 1: ... 703 V 35 or X 21 interfaces and can be provisioned to support simultaneous G 703 and Nx64 services The SHDSL interface is designed to operate from 192 kbps to 2 304 Mbps in 64 kbps increments or from 3 to 36 time slots with each time slot representing 64 kbps The SHDSL time slots can be multiplexed to the G 703 and or the Nx64 interfaces The maximum number of time slots that can be directed towar...

Page 2: ... n o c s i e c i v r e S R E B 3 E 0 1 R E B H A O L S I A S O L y l l a m r o n g n i t a r e p o t o n s i e c a f r e t n i d n a d e r u g i f n o c e c i v r e S k 4 6 x N f f O n e e r G d e R d e r u g i f n o c t o n e c i v r e S y l l a m r o n g n i t a r e p o s i e c a f r e t n i d n a d e r u g i f n o c e c i v r e S r o f f O R T D t n e s e r p s m r a l a o t e u d y l l a m r o...

Page 3: ... only occur if enabled via the management interface The Local Loop Err Inj Remote Loop and BERT buttons will initiate terminate tests and the corresponding LEDs indicate the status of tests on this port only These tests are on the aggregate SHDSL payload Port Select will not operate if any locally initiated tests are in progress Table 2 Front Panel Pushbuttons l e b a L n o t t u B n o i t p i r c...

Page 4: ... i t c e n n o C o N 8 7 6 The 120 ohm balanced G 703 port uses a RJ 45 connector with the pinouts defined in Table 4 The G 703 port supports a 2048 Kbps port using a 120 ohm balanced interface that conforms to ITU T G 703 section 9 G 703 X 21 V 28 CONTROL 90 265VAC 48 65Hz 35 80VDC 250mA V 35 V 36 SHDSL CUSTOMER Nx64K NETWORK Figure 3 Express 6530 Back Panel Table 4 G 703 Pin Connections n i P n ...

Page 5: ...a D e v i e c e R 2 D X T a t a D t i m s n a r T 3 R T D o t d e t c e n n o c y l l a n r e t n I y d a e R l a n i m r e T a t a D R S D d n a D C D 4 D N G d n u o r G l a n g i S 5 R S D D C D o t d e t c e n n o c y l l a n r e t n I y d a e R t e S a t a D R T D d n a 6 S T R S T C o t d e t c e n n o c y l l a n r e t n I d n e S o T y d a e R 7 S T C S T R o t d e t c e n n o c y l l a n ...

Page 6: ...R O T N 1 4 1 k c a b p o o L l a c o L O T L 2 4 1 r o t a c i d n I t s e T M O R F N N Table 7 V 35 Pin Connections r e b m u N t i u c r i C e m a N t i u c r i C E C D m o r F o T B A t u o n i P b 2 0 1 a 2 0 1 2 0 1 d n u o r G l a n g i S 0 2 7 3 9 1 3 0 1 a t a D t i m s n a r T O T 2 2 4 4 0 1 a t a D e v i e c e R M O R F 4 2 6 5 0 1 d n e S o t t s e u q e R O T 5 2 7 6 0 1 d n e S o t...

Page 7: ... WARNING Risk of Electric Shock When Using a 2 Wire AC Power Connection the Green Yellow Earth Ground Wire Must Be Attached to the P6 2 Wire Quick Connect Post DB 15 IEC 320 E L N Ð STRAP MAP FACTORY DEFAULTS SHOWN 8 15 1 B A FILTER NOT LOADED FILTER E X 21 1 SGND 2 3 EGND P1 1 SGND 2 3 EGND P4 RX SHIELD TX SHIELD P5 1 SGND 2 3 EGND SHIELD G 703 RJ 45 3 6 Figure 4 Express 6530 Strap Map ...

Page 8: ...nal 3 G 703 RX Clock 2 SHDSL Options 1 Unit Options 3 G 703 Options 5 Test Options 4 Nx64k Options NTU LTU 1 Unit Mode 2 Cross Connect Map 3 LT Mode Clock Source 4 Circuit ID 5 Date and Time 8 Local Management 9 Change Password 7 Download Firmware 6 Reset Factory Defaults 2 SHDSL Remote Loopback 1 SHDSL Local Loopback 3 SHDSL BERT 4 G 703 Local Loopback 5 G 703 BERT 6 G 703 Services 8 Nx64k Remote...

Page 9: ...he framing will be locally generated if 32 is entered in the G 703 TS0 slot only If 32 is entered in the G 703 TS0 and the SHDSL TS0 then the framing will be passed transparently between the G 703 and SHDSL ports If values other than 32 are assigned to both the SHDSL TS0 slot and G 703 TS0 slot then the operation is G 703 unframed if other G 703 service values are assigned to the G 703 time slots ...

Page 10: ...in a service having the same delay An example is illustrated in Figure 7 All unused time slots contain a configurable bit pattern that is set via the management interface The default bit pattern is all 1s Unused time slots are those which are sent out of the G 703 port but are not part of a service The G 703 port transmits the unused time slot patterns and the receive ignores the unused time slots...

Page 11: ...S32 N A TS8 1 TS20 1 TS9 1 TS21 1 TS33 N A TS9 1 TS21 1 TS10 1 TS22 1 TS34 N A TS10 1 TS22 1 TS11 1 TS23 1 TS35 N A TS11 1 TS23 1 Timeslot Assignments Commands 0 Idle A Apply New Map G Full G 703 Service 1 31 G 703 Service 1 31 U Undo New Map N Full Nx64K Service 32 G 704 Frame Tab Select SHDSL or G 703 Timeslots 33 Nx64K Service Arrow Keys Move Cursor G 704 Framing N A Circuit ID 01 Jan 00 23 40 ...

Page 12: ...e SHDSL port and the Customer direction is always away from the SHDSL port Figure 10 Full Nx64k 2 Mbps Service Circuit ID 01 Jan 00 23 41 06 Unit Mode NT Provisioning Type Local Cross Connect Map SHDSL Timeslots G 703 Timeslots TS0 33 TS12 33 TS24 33 TS0 0 TS12 0 TS24 0 TS1 33 TS13 33 TS25 33 TS1 0 TS13 0 TS25 0 TS2 33 TS14 33 TS26 33 TS2 0 TS14 0 TS26 0 TS3 33 TS15 33 TS27 33 TS3 0 TS15 0 TS27 0 ...

Page 13: ... statistics and restarts the BERT In addition to the commands the following statistical information is provided Bit Error Rate Total number of bit errors divided by the total number of bits in the current test interval Bit Error Count Total number of bit errors in the current test interval Pattern Sync Loss Count Total number of times that the BERT has lost pattern sync Errored Seconds Total numbe...

Page 14: ...NTU and provides a loopback at the LTU in the customer direction Figure 17 AIS signal is injected into the network side Figure 16 Local Customer Nontransparent Loopback NTU TX AIS LTU Figure 17 Remote Customer Nontransparent Loopback Remote Network Transparent Loopback Initiated at the NTU and provides a loopback at the LTU in the network direction Figure 19 Data is passed transparently to the cus...

Page 15: ...Control Leads C141 LL On Initiates a Local Customer Loopback per the Nx64k port Loopback Type Option setting C141 LL Off C140 RL On Initiates a Remote Network Loopback per the remote unit Nx64k port Loopback Type Option setting C140 RL Off Receive In band Preparatory Signal Applies the loopback after detection of in band V 54 or PN127 remote looping pattern per the associated service Loopback Type...

Page 16: ...d When less than 32 time slots are configured on the G 703 port the NTU bases the CRC 4 detection generation on filling the unused time slots with a fixed pattern configurable via the management interface This CRC 4 detection generation is also required for multirate single or simultaneous services where less than 31 G 704 time slots are carried over the SHDSL line NOTE All framed services operate...

Page 17: ...bit s G 703 interface without any G 704 framing This implies that the whole SHDSL payload comprises a single service The following alarm conditions can be monitored on the G 703 G 704 interface if applicable to the current configuration 1 AIS Alarm Indication Signal 2 BER Excessive Bit Error Rate 3 LOMFA Loss of Multi Frame Alignment 4 LOF Loss of Frame 5 LOS Loss of Signal 6 RAI Remote Alarm Indi...

Page 18: ...face E1 Bit Rate 2 048 Mbps Connector RJ 45 120 ohm Balanced Interface Framing G 703 CCS CRC 4 enable disable Unframed Craft Port Bit Rate 2 4 kbps to 38 4 kbps Connector DB 9 Female V 28 Agency Approvals K 20 K 21 CISPER 22 IEC 950 CE MARK Environment Operating 0 C to 50 C 32 F to 122 F Storage 20 C to 70 C 4 F to 158 F Relative Humidity Up to 95 noncondensing Physical Dimensions 1 5 in H 9 0 in ...

Page 19: ...Numbers ADTRAN Inc Attention International Department 901 Explorer Boulevard Huntsville Alabama 35806 USA www adtran com international adtran com U S Headquarters 256 963 8000 voice 800 923 8726 voice 256 963 6300 fax 256 963 8200 fax back international adtran com Asia Pacific Beijing China 8610 8857 6415 voice 8610 8857 6417 fax sales china adtran com Asia Pacific Hong Kong 852 2824 8283 voice 85...

Page 20: ...20 61225101L1 5B ...

Reviews: